Error #116Critical⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

Victron MPPT Error #116: Factory Calibration Data Lost

Affected Models: Victron BlueSolar & SmartSolar MPPT Charge Controllers (All Models)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$0 (5-Year Warranty) - $400 (Out-of-Warranty Replacement)
Warranty may cover parts
Diag / Fix Time
Dealer RMA swap
Internal EEPROM Calibration Fault

⚡ Quick Engineering Answer

Victron Energy • Error #116

Victron Error #116 means the MPPT charge controller lost its factory voltage/current calibration data stored in internal memory. Crucially, distinguish ACTIVE vs HISTORICAL logs: if Error #116 stops charging today, the unit is hardware-faulty and must be replaced via your dealer. If it only sits in old 30-day history on a normally charging unit, Victron confirms it is a harmless factory-test artifact.

Recovery Behavior:Active Error #116 indicates permanent internal EEPROM corruption requiring Victron RMA hardware replacement; historical-only entries can be ignored.
SCHEMATIC // Victron Energy Error #116 — 48V Battery & MultiPlus/MPPT DC Bus
PERIMETER: SEALED ENCLOSURE
Victron Energy Error #116: PV Array, AFCI & DC Boost Stage System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PV Array, AFCI & DC Boost Stage
Signal / Power Path
Roof Strings / MC4 / Optimizers -> DC Isolator & MPPT
Safety Access Line
Sealed Chassis — Microcontroller Internal Calibration EEPROM

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Internal non-volatile calibration data corrupted or missing inside the MPPT microcontroller.
Trigger Threshold
Factory calibration EEPROM block fails startup checksum verification
Recovery Window
Non-recoverable by user/installer when actively latching; hardware replacement required
Subsystem Affected
Microcontroller Internal Calibration EEPROM
Warranty Outlook
100% covered under Victron 5-year hardware warranty when actively failing

How Victron Energy Error #116 Triggers

Every Victron solar charger undergoes individual shunt and ADC precision calibration during final manufacturing tests, writing unique correction offsets directly into protected processor memory. Error #116 reports that this calibration block failed checksum verification.

Wait before replacing hardware immediately: check whether Error #116 is currently ACTIVE or strictly HISTORICAL! Victron Energy engineers explicitly note that some legacy units retain a single Error #116 entry inside historical factory-test memory that can safely be ignored if the unit operates properly today. Conversely, if Error #116 appears as an active present alarm preventing solar output, voltage accuracy is compromised and internal hardware memory has failed permanently—requiring dealer warranty replacement.

🔀 Hardware & Series Differences

Active Present Error #116 (Charging Stopped)
Permanent corrupted EEPROM calibration in the unit

Cannot be fixed by firmware updates or user resets; contact dealer for Victron 5-year warranty RMA.

Historical-Only Log Entry (Charging Normal)
Leftover manufacturing bench-test diagnostic record

Ignore completely if today's status shows Bulk/Absorption/Float charging normally.

🔍 Observable Symptoms

  • •VictronConnect status screen locks charging with active Error #116 ('Calibration data lost').
  • •Voltage or amperage readings on VictronConnect appear wildly inaccurate or zeroed.
  • •Re-flashing latest firmware fails to restore calibration data.
  • •Occasionally spotted purely as a benign historical timestamp inside 30-day logs.

⚙️ Ranked Root Causes

Internal non-volatile EEPROM flash memory corruptionHigh

Bit flip or flash sector wear inside microprocessor erases factory calibration constants.

Lightning surge or extreme DC transient stressing logic ICMedium

Severe nearby lightning over-voltages corrupt protected flash memory.

Benign factory production test artifact preserved in historyMedium

Recorded prior to final calibration step on the factory line and left in history buffer.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Active Status vs Historical History Tab

Open VictronConnect: see if Status screen shows active Bulk/Float charging (ignore history) or halted Error #116.

2DISCHARGE / WAIT
Run One Safe 3-Minute External Isolator Cycle

If active, turn PV OFF first, battery OFF 3 mins, then battery ON and PV ON.

3SEQUENCE STEP
Save Serial Number for Victron RMA

If Error #116 locks charging persistently, capture a VictronConnect Service Report and contact your dealer.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Active Charging Fault vs Harmless History Artifact

Homeowner Safe

Open VictronConnect > Status tab during sunny daylight. If your unit actively enters Bulk/Absorption/Float with normal watts while #116 sits only under the old History tab, no repair is needed.

✓ Expected ResultAvoids unnecessary replacement of healthy controllers carrying old factory-line history records.
→ If Fault PersistsIf Status displays active Error #116 with 0W solar charging, proceed to reset test.
2

Perform One PV-First Power Cycle & Capture Service Report

Homeowner Safe

Isolate external PV switch first, battery switch second for 3 minutes, restore battery then PV; if active Error #116 persists, tap Settings > Product Info > Save Service Report in VictronConnect.

✓ Expected ResultCreates official Victron diagnostic file for instant warranty claim verification.
→ If Fault PersistsLeave PV switched OFF and contact your authorized Victron distributor.
3

Attempt Official Firmware Re-verify & Process Victron RMA

Licensed Technician

Verify clean battery supply voltage via multimeter, attempt official VictronConnect firmware reflash if available, and submit serial number plus VictronConnect Service Report for factory warranty exchange.

✓ Expected ResultAuthorized Victron dealer validates active calibration loss without field dismantling.
→ If Fault PersistsInstall replacement MPPT controller using existing fused terminals and inspect array grounding/SPD.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error #116? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •VictronConnect App (Service Report Export)
  • •Unit Serial Number Photo (Chassis Label)
  • •Original Dealer Invoice (Warranty)
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Victron Energy Error #116

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Is Victron Error #116 fixable by resetting to factory defaults?

No. Factory calibration data resides in low-level protected memory outside user defaults. An actively faulting unit requires Victron warranty replacement.

Why does my working Victron MPPT show Error #116 in History?

Victron officially notes that Error #116 occasionally appears as an old factory testing artifact in the history log. If your charger shows Bulk, Absorption, or Float normally today, ignore it safely.

How long is Victron's MPPT warranty for Error #116?

Victron Energy provides a 5-year standard warranty across BlueSolar and SmartSolar MPPT units, covering active factory calibration memory failure.

Related Victron Energy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026