Solar Inverter & Heat Pump
Fault Code Solutions
Don't spend hours searching through 200-page manufacturer PDF manuals. Get verified diagnostic checklists, safety ratings, repair costs, and step-by-step fix guides.
Browse by Manufacturer
Select your equipment maker to view all model-specific fault documentation
Growatt
One of the world's most widely installed residential solar inverters (MIN, MIC, SPH, and SPF series).
SolarEdge
Industry-leading DC-optimized inverter systems with HD-Wave technology and power optimizers.
Enphase
World leader in microinverter technology (IQ7, IQ8 series) and Envoy communication gateways.
Deye
Global manufacturer of high-efficiency hybrid inverters, low-voltage battery storage, and microinverters.
SMA Sunny Boy
German-engineered high-reliability residential and commercial string inverters.
Daikin Altherma
Europe's leading domestic heating and heat pump systems.
Fronius
Austrian engineered premium solar string inverters (Symo, Primo, Galvo, and Gen24 Plus series) renowned for SnapINverter modular architecture.
Victron Energy
Dutch manufacturer of professional off-grid power, marine, and mobile battery inverter/chargers (MultiPlus, Quattro, SmartSolar MPPT, Cerbo GX).
Sungrow
World-leading manufacturer of high-efficiency utility, commercial, and residential hybrid solar inverters (SG and SH series).
Mitsubishi Electric Ecodan
Market-leading Japanese air-source and water-source residential heat pumps featuring Zubadan flash-injection technology.
Where Fault Codes Originate Across Your Hardware
Every diagnostic page maps the exact subsystem fault zone and separates external homeowner checks from sealed internal high-voltage electronics.
Frequently Searched Fault Codes
Featured high-impact alerts across all 10 manufacturers — search any of 217 verified codes above
Growatt Error 102: Consistent Fault (Dual-CPU Sampling Mismatch)
Redundant DSP and slave safety microcontrollers measured mismatched voltage or frequency samples during pre-sync check.
Growatt Error 117: Internal AC Relay Fault (Grid Switch Failure)
AC grid isolation relay failed self-test feedback check at boot, freezing power export for anti-islanding safety.
SolarEdge Error 18x1E: AC Line-to-Neutral Voltage Below Threshold (V_LN Min)
Line-to-Neutral AC voltage fell below permissible lower threshold due to tripped breakers, brownouts, or poor neutral connection.
SolarEdge Error 18x86: PV Isolation Fault (Earth Ground Leakage)
High-voltage DC string insulation resistance (Riso) dropped below safe earth isolation threshold on SetApp single-phase inverters.
Enphase Envoy / IQ Gateway Not Reporting (Offline From Enlighten)
Enphase IQ Gateway lost internet connection to Enlighten Cloud, halting monitoring telemetry while solar keeps running.
Enphase DC Resistance Low — Power Off (Latched GFDI Fault)
Latched rooftop DC ground-fault protection permanently disabled an individual microinverter due to insulation leakage.
Deye Error F01: DC Input Polarity Reverse Fault
Inverted positive and negative DC polarity detected across one or more PV MPPT string inputs.
Deye Error F13: Working Mode / Grid Type Change Transition
Inverter paused momentarily to re-initialize power relays after changing Battery, Grid Type, or Operating Mode settings.
SMA Event 101: Grid Fault — High Grid Voltage / Line-Neutral Peak
Instantaneous AC phase voltage exceeded regional grid-code upper threshold, disconnecting feed-in safely.
SMA Event 3501: Insulation Failure (PV Array Earth Ground Fault)
Measured DC string insulation resistance (Riso) dropped below safe safety margin before closing onto utility lines.
Daikin Altherma Fault L5: Instantaneous Compressor Overcurrent
Outdoor inverter IPM bridge sensed severe compressor output overcurrent, halting drive immediately.
Daikin Altherma Fault C4: Heat Exchanger Thermistor Abnormality
Indoor plate/evaporator heat exchanger thermistor (R2T) reported out-of-range open or shorted resistance.
Fronius State 102: AC Grid Voltage Too High (Overvoltage Trip)
AC grid voltage exceeded upper statutory protection limit, pausing solar feed-in to protect home appliances and grid stability.
Fronius State 240: DC Arc Detected (AFCI Safety Shutdown)
AFCI safety hardware detected dangerous DC arcing on solar string wiring and locked out production.
Victron MultiPlus: Low Battery Pre-Alarm & Dynamic Cutoff
DC terminal voltage at the MultiPlus dropped below the low-battery pre-alarm or dynamic shutdown threshold.
Victron MultiPlus VE.Bus Error 8: Ground Relay Test Failed
Inverter/charger failed its internal safety ground relay self-test on startup or grid connection.
Sungrow Fault 014: 10-Minute Average Grid Overvoltage Trip
The rolling 10-minute average AC voltage at the Sungrow grid terminals exceeded regulatory limits, forcing a temporary grid export pause.
Sungrow Fault 039: Low System Insulation Resistance (ISO Fault)
Pre-startup insulation testing measured DC PV-to-earth resistance below minimum IEC safety limits, locking out grid connection to prevent shock or arc fires.
Mitsubishi Ecodan Fault L5: Water Thermistor Open or Short
FTC control board measured an out-of-range voltage, unplugged harness, or short on a THW water thermistor.
Mitsubishi Ecodan Fault J5: Wireless Thermostat Communication Fault
Wireless receiver lost RF radio link from the battery-powered wireless thermostat assigned to zone address 5.