Deye Error Codes & Fix Guides

Global manufacturer of high-efficiency hybrid inverters, low-voltage battery storage, and microinverters. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.

Deye Hardware Signal Topology

Hybrid Solar Inverter
HV DCACPV Array StringsMPPT • AFCI • RisoDC Isolator & SPDDeye CoreMPPT Boost • IGBT BridgeDual-CPU • RCMU • RelaysGrid & BreakerPLL Voltage / FreqRS485 CT & MainsBMS / Storage BusCAN / RS485 / Wi-FiPE Earth & Riso ⏚GFCI / Leakage Sensing

Deye Diagnostic Profile (26 Codes)

DIY Safe (External): 4 (15%)Pro Only: 22
Auto-Recovering: 20 (77%)Latched: 6
Severity Distribution
● Crit 12● High 12● Warn/Med 1● Info/Low 1
OEM Manual Coverage: 100%OEM Portal ↗
Showing 26 / 26
Error F01
Pro OnlyCritical

Deye Error F01: DC Input Polarity Reverse Fault

Inverted positive and negative DC polarity detected across one or more PV MPPT string inputs.

Est. Cost: $140 - $340Fix Guide →
Error F08
Pro OnlyCritical

Deye Error F08: GFDI Relay Failure / Ground Start Fault

Inverter failed startup GFDI ground-relay verification or detected mismatched grid/neutral earthing configuration.

Est. Cost: $140 - $420Fix Guide →
Error F13
DIY SafeLow

Deye Error F13: Working Mode / Grid Type Change Transition

Inverter paused momentarily to re-initialize power relays after changing Battery, Grid Type, or Operating Mode settings.

Est. Cost: $0Fix Guide →
Error F14
Pro OnlyCritical

Deye Error F14: Software DC Overcurrent Fault

DC input current from solar PV strings or DC converter stage exceeded software current limits.

Est. Cost: $140 - $420Fix Guide →
Error F16
Pro OnlyCritical

Deye Error F16: GFCI / AC Leakage Current Fault (>300mA)

Inverter internal GFCI sensor measured excessive continuous leakage current to ground (>300mA safety limit).

Est. Cost: $160 - $480Fix Guide →
Error F18
Pro OnlyCritical

Deye Error F18: Hardware AC Overcurrent Fault

Hardware protection circuit detected sudden excessive AC output or grid port current past transistor ratings.

Est. Cost: $140 - $520Fix Guide →
Error F20
Pro OnlyCritical

Deye Error F20: Hardware DC Overcurrent Fault

Fast analog hardware protection tripped due to excessive DC current surge on the PV or battery converter stage.

Est. Cost: $160 - $560Fix Guide →
Error F22
Pro OnlyHigh

Deye Error F22: Emergency Stop / Remote Shutdown (Hybrid)

Inverter received an active Emergency Stop / Rapid Shutdown signal on hybrids, or phase/leakage alert on string units.

Est. Cost: $80 - $280Fix Guide →
Error F23
Pro OnlyHigh

Deye Error F23: GFCI Transient Leakage Current Fault

Internal GFCI/RCMU protection caught a sharp instantaneous step spike in AC/DC earth leakage current.

Est. Cost: $140 - $420Fix Guide →
Error F24
Pro OnlyCritical

Deye Error F24: DC Insulation Impedance Failure (Riso Fault)

Pre-startup insulation resistance test failed between rooftop PV array conductors and Protective Earth ground.

Est. Cost: $160 - $520Fix Guide →
Error F26
Pro OnlyCritical

Deye Error F26: DC Busbar Unbalanced (Half-Bus Voltage Fault)

Asymmetry exceeded safety tolerance between upper (+Bus) and lower (-Bus) internal high-voltage DC bus capacitors.

Est. Cost: $220 - $680Fix Guide →
Error F29
Pro OnlyCritical

Deye Error F29: Parallel CAN Bus Communication Fault

Parallel inverter cluster lost CAN communication synchronization across RJ45 parallel interconnect ports.

Est. Cost: $100 - $340Fix Guide →
Error F30
Pro OnlyCritical

Deye Error F30: AC Main Contactor / Grid Relay Fault

Internal AC grid transfer relay or contactor failed self-test verification prior to grid synchronization.

Est. Cost: $180 - $560Fix Guide →
Error F33
Pro OnlyHigh

Deye Error F33: Temperature Sensor Fault / AC Overcurrent (Series Diff)

Internal NTC temperature sensor reading out of bounds on Deye hybrids, or AC overcurrent trip on grid-tied string models.

Est. Cost: $140 - $380Fix Guide →
Error F34
Pro OnlyHigh

Deye Error F34: AC Overcurrent / Backup Overload Fault

AC output load on the Backup/UPS port exceeded continuous current ratings (or internal comms timeout on select string models).

Est. Cost: $120 - $360Fix Guide →
Error F35
DIY SafeMedium

Deye Error F35: No Utility Grid Detected (AC Loss / Outage)

Inverter sensed complete loss of external AC utility voltage on its Grid input terminals.

Est. Cost: $0 - $220Fix Guide →
Error F41
Pro OnlyCritical

Deye Error F41: Parallel System Stop (Cascaded Cluster Halt)

Cascade protection stopped parallel-connected hybrid inverters after a sibling inverter faulted (or High Grid Voltage on single string models).

Est. Cost: $100 - $360Fix Guide →
Error F42
Pro OnlyHigh

Deye Error F42: AC Line Low Voltage (Phase W-U / Undervoltage)

AC utility grid voltage (specifically Line W-U on 3-phase systems) dropped below the configured lower grid protection ceiling.

Est. Cost: $100 - $320Fix Guide →
Error F44
Pro OnlyHigh

Deye Error F44: AC Line Low Voltage (V-W) / PV Polarity (String Diff)

AC line-to-line voltage across phases V–W fell beneath grid code limits (or PV polarity warning on specific string units).

Est. Cost: $100 - $340Fix Guide →
Error F46
Pro OnlyHigh

Deye Error F46: Backup Battery Fault / AC Line U-V Low (Series Diff)

Backup battery startup/voltage check error on LV hybrids, MPPT self-check error, or AC Line U-V undervoltage on three-phase units.

Est. Cost: $120 - $380Fix Guide →
Error F47
DIY SafeHigh

Deye Error F47: AC Grid Overfrequency Protection Trip

AC grid or generator port frequency exceeded upper permitted Grid Code ceiling (or EEPROM mismatch on legacy string units).

Est. Cost: $0 - $200Fix Guide →
Error F48
DIY SafeHigh

Deye Error F48: AC Grid Underfrequency Protection Trip

Utility grid or backup generator AC frequency dropped below minimum permissible synchronization floor.

Est. Cost: $0 - $220Fix Guide →
Error F56
Pro OnlyHigh

Deye Error F56: DC Busbar Voltage Too Low (Hybrid) / Phase Loss (String)

Internal DC bus voltage collapsed below minimum conversion threshold from battery cutoff or dusk solar fade.

Est. Cost: $100 - $340Fix Guide →
Error F58
Pro OnlyHigh

Deye Error F58: BMS Communication Fault (CAN / RS485)

Hybrid inverter lost closed-loop CAN or RS485 communication with the lithium battery Management System (BMS).

Est. Cost: $90 - $260Fix Guide →
Error F63
Pro OnlyCritical

Deye Error F63: DC Arc Fault Detection (AFCI) / MCU Safety Fault

AFCI sensor detected high-frequency electrical sparking noise on solar DC strings (or MCU safety/thermal fault on non-AFCI series).

Est. Cost: $180 - $540Fix Guide →
Error F64
Pro OnlyHigh

Deye Error F64: IGBT Heat Sink High Temperature Fault

Internal IGBT power-stage heatsink exceeded safe operating temperature, triggering thermal shutdown.

Est. Cost: $120 - $380Fix Guide →