Deye Error Codes & Fix Guides
Global manufacturer of high-efficiency hybrid inverters, low-voltage battery storage, and microinverters. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Deye Hardware Signal Topology
Deye Diagnostic Profile (26 Codes)
Deye Error F01: DC Input Polarity Reverse Fault
Inverted positive and negative DC polarity detected across one or more PV MPPT string inputs.
Deye Error F08: GFDI Relay Failure / Ground Start Fault
Inverter failed startup GFDI ground-relay verification or detected mismatched grid/neutral earthing configuration.
Deye Error F13: Working Mode / Grid Type Change Transition
Inverter paused momentarily to re-initialize power relays after changing Battery, Grid Type, or Operating Mode settings.
Deye Error F14: Software DC Overcurrent Fault
DC input current from solar PV strings or DC converter stage exceeded software current limits.
Deye Error F16: GFCI / AC Leakage Current Fault (>300mA)
Inverter internal GFCI sensor measured excessive continuous leakage current to ground (>300mA safety limit).
Deye Error F18: Hardware AC Overcurrent Fault
Hardware protection circuit detected sudden excessive AC output or grid port current past transistor ratings.
Deye Error F20: Hardware DC Overcurrent Fault
Fast analog hardware protection tripped due to excessive DC current surge on the PV or battery converter stage.
Deye Error F22: Emergency Stop / Remote Shutdown (Hybrid)
Inverter received an active Emergency Stop / Rapid Shutdown signal on hybrids, or phase/leakage alert on string units.
Deye Error F23: GFCI Transient Leakage Current Fault
Internal GFCI/RCMU protection caught a sharp instantaneous step spike in AC/DC earth leakage current.
Deye Error F24: DC Insulation Impedance Failure (Riso Fault)
Pre-startup insulation resistance test failed between rooftop PV array conductors and Protective Earth ground.
Deye Error F26: DC Busbar Unbalanced (Half-Bus Voltage Fault)
Asymmetry exceeded safety tolerance between upper (+Bus) and lower (-Bus) internal high-voltage DC bus capacitors.
Deye Error F29: Parallel CAN Bus Communication Fault
Parallel inverter cluster lost CAN communication synchronization across RJ45 parallel interconnect ports.
Deye Error F30: AC Main Contactor / Grid Relay Fault
Internal AC grid transfer relay or contactor failed self-test verification prior to grid synchronization.
Deye Error F33: Temperature Sensor Fault / AC Overcurrent (Series Diff)
Internal NTC temperature sensor reading out of bounds on Deye hybrids, or AC overcurrent trip on grid-tied string models.
Deye Error F34: AC Overcurrent / Backup Overload Fault
AC output load on the Backup/UPS port exceeded continuous current ratings (or internal comms timeout on select string models).
Deye Error F35: No Utility Grid Detected (AC Loss / Outage)
Inverter sensed complete loss of external AC utility voltage on its Grid input terminals.
Deye Error F41: Parallel System Stop (Cascaded Cluster Halt)
Cascade protection stopped parallel-connected hybrid inverters after a sibling inverter faulted (or High Grid Voltage on single string models).
Deye Error F42: AC Line Low Voltage (Phase W-U / Undervoltage)
AC utility grid voltage (specifically Line W-U on 3-phase systems) dropped below the configured lower grid protection ceiling.
Deye Error F44: AC Line Low Voltage (V-W) / PV Polarity (String Diff)
AC line-to-line voltage across phases V–W fell beneath grid code limits (or PV polarity warning on specific string units).
Deye Error F46: Backup Battery Fault / AC Line U-V Low (Series Diff)
Backup battery startup/voltage check error on LV hybrids, MPPT self-check error, or AC Line U-V undervoltage on three-phase units.
Deye Error F47: AC Grid Overfrequency Protection Trip
AC grid or generator port frequency exceeded upper permitted Grid Code ceiling (or EEPROM mismatch on legacy string units).
Deye Error F48: AC Grid Underfrequency Protection Trip
Utility grid or backup generator AC frequency dropped below minimum permissible synchronization floor.
Deye Error F56: DC Busbar Voltage Too Low (Hybrid) / Phase Loss (String)
Internal DC bus voltage collapsed below minimum conversion threshold from battery cutoff or dusk solar fade.
Deye Error F58: BMS Communication Fault (CAN / RS485)
Hybrid inverter lost closed-loop CAN or RS485 communication with the lithium battery Management System (BMS).
Deye Error F63: DC Arc Fault Detection (AFCI) / MCU Safety Fault
AFCI sensor detected high-frequency electrical sparking noise on solar DC strings (or MCU safety/thermal fault on non-AFCI series).
Deye Error F64: IGBT Heat Sink High Temperature Fault
Internal IGBT power-stage heatsink exceeded safe operating temperature, triggering thermal shutdown.