Deye Error F24: DC Insulation Impedance Failure (Riso Fault)

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SUN-SG05LP1, SG01HP3 & SUN-G03 String Inverters

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$160 - $520 USD
Warranty may cover parts
Diag / Fix Time
60 - 150 mins
PV Array Insulation Resistance (Riso)

⚡ Quick Engineering Answer

Deye • Error F24

Deye Error F24 means DC Insulation Impedance Failure (DC_Insulation_Fault / low Riso)—not an AC current sensor fault (which old blogs wrongly claim). Before connecting solar relays at dawn, the inverter detected low resistance between PV strings and earth ground caused by soaked connectors, pinched cables, or shattered panels. Switch PV OFF safely; string megger diagnostics require a technician.

Recovery Behavior:Safety lockout blocks PV connection at startup whenever PV-to-earth insulation falls below safety threshold; requires repairing compromised solar cabling.
SCHEMATIC // Deye Error F24 — Hybrid PV + Storage Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Deye Error F24: PE Ground Bond, RCMU & Array Riso System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PE Ground Bond, RCMU & Array Riso
Signal / Power Path
Rooftop Moisture Path, Differential Toroid & PE Earth
Safety Access Line
Sealed Chassis — PV String Insulation Sensing Circuit & Rooftop Cabling

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Pre-startup insulation resistance test failed between rooftop PV array conductors and Protective Earth ground.
Trigger Threshold
Array insulation resistance (Riso) drops below safe startup floor (typically < 100–500 kΩ / 1 MΩ)
Recovery Window
Re-tests periodically or on restart; persists permanently while damaged string remains soaked/shorted
Subsystem Affected
PV String Insulation Sensing Circuit & Rooftop Cabling
Warranty Outlook
Internal board sensing defect covered by warranty; roof water/rodent leaks billed as array repair

How Deye Error F24 Triggers

Every morning before engaging MPPT boost stages, Deye hybrid and string inverters inject a tiny safe test voltage between the solar DC inputs and chassis Protective Earth (PE) to measure array Riso (Insulation Resistance). Under IEC 62109 safety compliance, if resistance between either PV+ or PV- to earth drops below statutory limits (often <100 kΩ–1 MΩ depending on voltage class), Error F24 locks solar power offline cleanly.

Notice how F24 differs from F16/F23: F24 tests insulation health statically BEFORE active inversion begins (commonly catching rain-soaked MC4 connectors pooling in roof gutters, mouse-chewed DC sheathing inside attic conduits, water inside a rooftop DC isolator, or cracked solar glass backsheets). Never bypass F24 earthing checks—ungrounded DC ground faults create severe roof fire hazards.

🔀 Hardware & Series Differences

Deye Hybrid & Grid String Models
DC_Insulation_Fault: low resistance between PV+ / PV- conductors and Earth PE

Commonly strikes first on wet mornings after hailstorms, roof work, or rodent damage.

Floating vs Grounded Negative Legacy Checks
If external bonding bridges PV- to ground directly without transformer isolation, F24 locks continuously

Ensure modern transformerless Deye PV strings always run strictly floating relative to Earth.

🔍 Observable Symptoms

  • •Inverter locks out early morning with Error F24 while refusing PV harvest all cloudy/wet day.
  • •Often unlocks partially on hot dry afternoons only to return every damp sunrise.
  • •Exterior rooftop DC isolator housing shows moisture condensation inside.
  • •Visible darkened or blistered backsheet on an old solar panel.

⚙️ Ranked Root Causes

Water pooled inside submerged MC4 connectors or flooded exterior DC isolator boxHigh

Waterproof seals degrade or lose gaskets when mounted pointing upright in roof gutters.

Pinched, UV-cracked, or rodent-bitten PV conduit wiring touching steel rackingHigh

Sharp metal tile edges or attic rodents expose bare copper strands to wet structures.

Delaminated solar module junction box or shattered panel glass soaking cellsMedium

Hail or thermal aging lets rainwater penetrate live PV laminates to aluminum frame.

Defective internal Riso resistor bridge on inverter power PCBLow

Internal sensing failure falsely triggers F24 even with external PV switch OFF.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1DC / BATT OFF
Turn External PV DC Isolator OFF Safely

Isolate the leaking solar array completely before walking around metal framing.

2DC / BATT OFF
Test Inverter Startup With PV Switch Kept OFF

Boot inverter on battery/AC only to verify error stems externally from solar strings.

3DC / BATT OFF
Schedule 1000V DC String Megger Isolation

Do not climb wet roofs or disconnect DC solar strings yourself; live PV remains hazardous.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Run PV-Isolated Inverter Check & Review Rain Logs

Homeowner Safe

Switch external PV rotary isolator OFF completely (leaving battery/AC switches ON) and perform one quick controller reboot to verify F24 doesn't trigger when rooftop wires stay disconnected.

✓ Expected ResultConfirms inverter hardware is healthy and fault lies cleanly inside rooftop strings/isolator.
→ If Fault PersistsImmediate F24 while external PV switch stays OFF confirms internal inverter Riso sensor failure.
2

Look Visually Around Exterior DC Isolator & Conduit (No Touching)

Homeowner Safe

From ground level safely check whether water trails, broken roof conduit, or cracked exterior DC switch boxes are visible near the inverter wall.

✓ Expected ResultSpot obvious outdoor conduit breaks or flooded switch enclosures rapidly.
→ If Fault PersistsKeep external PV isolator switched OFF until technician tests string insulation.
3

Measure PV1 / PV2 Insulation Resistance With 500V/1000V Megger

Licensed Technician

Isolate DC safely, unplug each string independently, check VOC-to-ground voltage first (high Voc-to-ground pinpoints faulted panel location along series string!), then run 500V/1000V insulation megger across string +/- to Earth.

✓ Expected ResultCalculates exact fault location down to which panel in the series string sits wet!
→ If Fault PersistsInspect rooftop DC isolators and junction boxes on the single bad string.
4

Re-Terminate Wet Splices / Replace Faulted Module & Verify >100 MΩ

Licensed Technician

Replace flooded MC4 connectors, replace degraded conduit or wet DC switches, swap delaminated panels, secure zip-ties off roof surfaces, and verify Riso exceeds >100 MΩ before reconnecting inverter.

✓ Expected ResultError F24 disappears permanently even under simulated spray/rain checks.
→ If Fault PersistsReplace faulted Riso PCB if bench strings test clean >100 MΩ.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F24? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •1000V DC Insulation Resistance Tester (Megger)
  • •True-RMS Multimeter (Voltage-to-Ground Method)
  • •IP68 Matched MC4 Connectors & Cable Ties
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Deye Error F24

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Does Deye Error F24 mean an AC current sensor calibration error?

No—that is outdated/wrong data on some blogs. Official Deye service manuals designate Error F24 strictly as DC Insulation Impedance Failure (low Riso between solar strings and earth).

How can a solar technician find the exact bad panel out of 12 panels in a string?

Using the Voltage-to-Ground method! Measuring Voc from Positive-to-Earth and Negative-to-Earth points accurately to the percentage point along the series string where moisture bridges to metal framing.

Can spraying water on dusty solar panels trigger Deye Error F24?

Yes—if water jets hit aged junction boxes or loose MC4 couplings lying directly under modules on hot tiles, rapid capillary moisture drop triggers F24 immediately.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026