Deye Error F16: GFCI / AC Leakage Current Fault (>300mA)

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SUN-SG05LP1 & SUN-G03 String Inverters

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$160 - $480 USD
Warranty may cover parts
Diag / Fix Time
60 - 150 mins
Residual Leakage Current & GFCI

⚡ Quick Engineering Answer

Deye • Error F16

Deye Error F16 indicates sustained residual AC/DC leakage current to Protective Earth exceeding statutory GFCI thresholds (typically >300mA RMS)—posing a genuine shock hazard if damp rooftop PV cables or pinched MC4 plugs leak voltage onto aluminum mounting rails. Safely turn off PV DC isolator when wet; insulation testing requires an electrician.

Recovery Behavior:Auto-retries briefly after fault clears; persistent leakage (>300mA RCD trip) locks system due to electrocution risk until insulation is repaired.
SCHEMATIC // Deye Error F16 — Hybrid PV + Storage Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Deye Error F16: PE Ground Bond, RCMU & Array Riso System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PE Ground Bond, RCMU & Array Riso
Signal / Power Path
Rooftop Moisture Path, Differential Toroid & PE Earth
Safety Access Line
Sealed Chassis — Internal GFCI / RCMU Toroid Sensor & PV Array Earth

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter internal GFCI sensor measured excessive continuous leakage current to ground (>300mA safety limit).
Trigger Threshold
Steady residual leakage current exceeds ~300 mA continuous statutory safety limit
Recovery Window
May auto-restart once insulation dries; recurring fault latches until array leak repairs
Subsystem Affected
Internal GFCI / RCMU Toroid Sensor & PV Array Earth
Warranty Outlook
Internal sensor fault covered under warranty; wet roof wiring / animal damage excluded

How Deye Error F16 Triggers

Transformerless solar and hybrid inverters connect the utility AC grid dynamically to rooftop PV arrays through high-frequency switching stages, meaning defective solar module insulation can transmit dangerous shock currents directly down grounded frames. To prevent electrocution and electrical fires, Deye embeds precision Residual Current Monitoring (RCMU / GFCI) toroids that trigger Error F16 whenever steady leakage current climbs above 300 mA.

Crucially, F16 differs from transient spikes (F23) by representing sustained average leakage—most noticeably in humid early mornings, heavy rainstorms soaking deteriorated roof MC4 splices, or compromised inverter PE earthing. While some moisture errors vanish temporarily once rooftops dry at noon, never dismiss recurring F16 warnings.

🔀 Hardware & Series Differences

Deye Hybrid Inverters (SG04LP1 / LP3)
Continuous average leakage current >300mA detected by internal GFCI toroid

Frequently strikes first thing after rainy nights due to pooled water inside roof trays or wet junction boxes.

Large Commercial Rooftop String Arrays
Higher natural panel capacitive earth leakage across damp glass plus degraded wiring

Verify proper PE earthing cable size and split suspect arrays systematically during megger insulation testing.

🔍 Observable Symptoms

  • •Inverter disconnects grid export and flags Error F16 right during morning dew or rain.
  • •Touchscreen alarm clears spontaneously around midday heat only to return next rainstorm.
  • •House external RCD/GFCI circuit breaker may trip simultaneously.
  • •Occurs continuously if an internal GFCI toroid coil failed.

⚙️ Ranked Root Causes

Rainwater ingress inside cracked rooftop MC4 plugs, junction boxes, or DC conduitHigh

Pooled water inside upside-down or non-watertight splices bridges high DC voltage to aluminum framing.

Pinched or rodent-chewed PV cable insulation touching grounded roof rackingHigh

UV-brittle or abraded solar cable leaks steady earth current whenever moisture condenses.

Missing or loose inverter PE Protective Earth terminal connectionMedium

Poor reference ground confuses differential current sensing across internal filter capacitors.

Damaged internal GFCI sensing transformer or auxiliary relayLow

Defective toroid reports >300mA even with external PV isolators open.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1SEQUENCE STEP
Correlate Timing Against Morning Rain / Humidity

Note whether F16 triggers specifically during damp weather before resetting switches.

2DC / BATT OFF
Do Not Touch Metal Racking While Fault Active

Treat active ground-leakage warnings respectfully; rotate external PV isolator OFF safely.

3RESTORE & BOOT
Run 1-Min External Power Cycle Once Dry

Turn PV -> Battery -> AC OFF for 60s and restore; book rooftop megger test if fault returns.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Check Rain Timing & Isolate PV Safely If Active

Homeowner Safe

Check whether Error F16 appears exclusively during rainfall or early-morning dew; if actively locked on, switch the external PV DC isolator OFF for safety and photograph timestamps in Solarman.

✓ Expected ResultCorrelates leakage strongly to damp rooftop splices while neutralizing shock risk.
→ If Fault PersistsAvoid touching roof racking or metal conduits until an electrician clears ground faults.
2

Verify Fault Clears or Persists With PV Switch OFF

Homeowner Safe

Restart Battery and AC breakers with external PV switch STILL OFF (no solar generation). Note if F16 vanishes or persists immediately.

✓ Expected ResultZero F16 with PV disconnected proves external array insulation leakage rather than internal inverter failure.
→ If Fault PersistsImmediate F16 with zero PV attached signals an AC/earth issue or defective internal GFCI toroid.
3

Isolate Strings & Perform 500V/1000V Megger Insulation Test

Licensed Technician

Disconnect strings safely from inverter, test positive-to-earth and negative-to-earth insulation resistance across each string individually, and locate damp or low-resistance strings (<1 MΩ).

✓ Expected ResultIsolates the single leaking rooftop string cleanly without stripping every panel.
→ If Fault PersistsVerify PE protective earth bonding tightness on inverter chassis and backup circuits.
4

Replace Compromised Connectors / Cabling or Service GFCI Sensor

Licensed Technician

Inspect damaged MC4 pairs and pinched conduits under the compromised string, replace moisture-compromised sections with IP68 rated fittings mounted off roof surfaces, or replace faulty GFCI PCB.

✓ Expected ResultInsulation resistance tests >100 MΩ dry/damp and F16 clears permanently.
→ If Fault PersistsVerify capacitive panel leakage thresholds on large ungrounded arrays.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F16? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •500V/1000V DC Insulation Tester (Megger)
  • •True-RMS Earth Leakage Clamp Meter
  • •Waterproof IP68 MC4 Spanners & Cable
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Deye Error F16

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Why does Deye F16 go away by itself every afternoon?

Morning condensation and rainwater dry out under warm afternoon sunlight, temporarily raising rooftop string resistance back over 300mA cutoff until the next damp morning—meaning a cracked connector still needs repair!

Is Error F16 a faulty GFCI sensor inside the inverter?

Rarely. In over 85% of real-world cases F16 detects genuine damp rooftop MC4 splicing or abraded solar cable insulation, though F16 locking with PV unplugged confirms sensor failure.

What is the difference between Deye F16 and F23?

F16 measures continuous average ground leakage exceeding ~300 mA RMS, whereas F23 trips on sudden instantaneous leakage jumps (>30 mA/60 mA step shifts).

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026