Master Fault Code Directory

Direct index of every verified diagnostic record on VoltFaults. Filter by keyword, severity, or DIY safety scope, or jump to a manufacturer section below.

DIY Safe: 57 (26%)Pro Service: 160
Auto-Recover: 112 (52%)Latched: 105
Crit 108High 32Warn 65Info 12
217 / 217

Growatt

Solar Inverter

One of the world's most widely installed residential solar inverters (MIN, MIC, SPH, and SPF series).

Open Growatt Hub (30)→
Error 102
DIYCritical

Growatt Error 102: Consistent Fault (Dual-CPU Sampling Mismatch)

Redundant DSP and slave safety microcontrollers measured mismatched voltage or frequency samples during pre-sync check.

Error 111
PROWarning

Growatt Error / Warning 111: Neutral-Earth Fault, Export Comms or IGBT Check

Model-specific fault flagging Neutral-to-Earth voltage deviation, smart-meter export limitation failure, or legacy IGBT gate fault.

Error 117
PROCritical

Growatt Error 117: Internal AC Relay Fault (Grid Switch Failure)

AC grid isolation relay failed self-test feedback check at boot, freezing power export for anti-islanding safety.

Error 120
PROCritical

Growatt Error 120: HCT Internal Current Sensor Fault

Internal Hall-effect output current sensor failed startup zero-current offset calibration check.

Error 121
DIYCritical

Growatt Error 121: Internal Communication / Processor Fault

Internal SPI/UART handshake dropped between main DSP processor and communication/auxiliary control module.

Error 129
DIYWarning

Growatt Error 129: AC Voltage Out of Range / Output Abnormal

Detected utility AC voltage climbed above or sagged below configured regional safety thresholds, pausing grid feed-in.

Error 130
DIYWarning

Growatt Error 130: AC Grid Frequency Out of Range (AC F Outrange)

Utility grid frequency drifted past regional 50 Hz / 60 Hz safety limits, pausing AC generation cleanly.

Warning 201
PROCritical

Growatt Warning / Error 201: Residual Leakage Current Too High (GFCI)

Internal GFCI current transformer sensed hazardous residual earth leakage exceeding safety cutoff.

Warning 202
PROCritical

Growatt Error / Warning 202: PV Voltage High (DC Input Overvoltage)

Combined PV string open-circuit voltage exceeded safe inverter DC maximum limit, locking conversion to protect DC bus capacitors.

Warning 203
PROCritical

Growatt Error / Warning 203: PV Isolation Low (Low Riso Earth Fault)

Low insulation resistance detected between rooftop PV conductors and Protective Earth ground prior to startup synchronization.

Warning 204
PROCritical

Growatt Warning / Error 204: Dry Contact Fault or PV Polarity Reversed

Auxiliary dry-contact control logic anomaly or reversed PV string DC polarity preventing safe array wake-up.

Warning 205
PROCritical

Growatt Warning / Error 205: PV1 or PV2 Boost Converter Broken

Hardware failure inside the DC-DC MPPT boost stage for PV1 or PV2, blocking safe energy lift onto the internal DC bus.

Warning 206
PROWarning

Growatt Warning 206: AC Surge Protection Device (SPD) Abnormal

Thermal disconnect flag on internal/modular AC Surge Protection Device signaled a sacrificial varistor blowout or open feedback loop.

Warning 207
DIYWarning

Growatt Warning 207: USB / U-Disk Over-Current Protection

USB/Datalogger port 5V supply rail tripped electronic over-current fuse protection due to shorted logger or flash drive.

Warning 208
PROCritical

Growatt Warning 208: DC String Fuse Open or Sampling Fault

Blown rooftop string DC gPV fuse detected (or model-specific internal string sampling discrepancy), halving that MPPT input.

Error 300
PROWarning

Growatt Error 300: AC V Outrange (Grid Voltage Out of Range)

AC grid voltage measured outside programmed regional upper or lower safety thresholds, opening grid relays.

Error 301
PROCritical

Growatt Error 301: AC Terminals Reversed (Live / Neutral Polarity Swap)

Swapped AC Line and Neutral wiring polarity detected at the inverter output terminals, locking synchronization.

Error 302
DIYCritical

Growatt Error 302: No AC Connection (Utility Grid or Breaker Loss)

Inverter sees zero incoming utility AC voltage at its grid port due to a utility outage, tripped breaker, or open isolator.

Error 303
PROCritical

Growatt Error 303: NE Abnormal (Neutral-to-Earth Voltage Fault)

Excessive AC voltage difference (>30V) measured between Neutral and Protective Earth conductors, halting output safely.

Warning 401
PROWarning

Growatt Warning 401: Inverter Communicates with Meter Abnormal

Lost RS485 Modbus communication between Growatt inverter and external export/consumption Smart Meter.

Warning 404
PROCritical

Growatt Warning 404: EEPROM Read/Write & Bus Sample Fault

Non-volatile EEPROM checksum corruption or DC bus sampling failure prevented startup calibration verification.

Warning 405
PROCritical

Growatt Warning 405: Relay Fault (Grid Isolation Relay Failure)

Mechanical AC grid isolation relays failed open/close self-diagnostics prior to synchronization, locking output safely.

Error 407
PROWarning

Growatt Error 407: Auto Test Failed (Compliance Self-Test Fault)

Automated utility protection self-test sequence aborted or exceeded trip-time limits under grid-code compliance checks.

Error 409
PROCritical

Growatt Error 409: Bus Overvoltage (Internal DC Link Volt High)

Internal inverter DC bus voltage surged beyond component safety limits during operation or cold solar startup.

Error 411
PROCritical

Growatt Error 411: DSP & M3 Internal Processor Comm Fault

Lost internal serial link between main DSP power processor and slave M3 safety microcontroller.

Warning 412
PROWarning

Growatt Warning 412: Temp Sensor / Internal Connection Abnormal

Internal NTC thermistor telemetry drifted outside physically possible temperature limits or lost harness continuity.

Error 413
PROCritical

Growatt Error 413: IGBT Drive Fault (Power Stage Failure)

High-voltage IGBT switching driver circuit reported desaturation/overcurrent fault, shutting down power conversion.

Error 417
PROCritical

Growatt Error 417: DSP-M3 Protocol Version Mismatch

DSP power controller and M3 safety processor are running incompatible firmware versions after partial update.

Error 418
PROWarning

Growatt Error 418: DSP & COM Controller Firmware Unmatch

Incompatible firmware revisions detected between the main DSP inverter board and the COM communication board.

Warning 420
PROCritical

Growatt Warning 420: GFCI Module Damage (Leakage Sensor Fault)

Internal GFCI/RCD residual current transformer failed its startup self-calibration check, disabling output safely.

SolarEdge

Solar Inverter & Optimizers

Industry-leading DC-optimized inverter systems with HD-Wave technology and power optimizers.

Open SolarEdge Hub (26)→
Error 18x86
PROCritical

SolarEdge Error 18x86: PV Isolation Fault (Earth Ground Leakage)

High-voltage DC string insulation resistance (`Riso`) dropped below safe earth isolation threshold on SetApp single-phase inverters.

Error 8x58
PROCritical

SolarEdge Error 8x58: Three-Phase / Synergy Array Isolation Fault

Three-phase / Synergy inverter detected earth leakage across parallel DC solar strings dropping isolation resistance below 1 MΩ.

Error 18xC
PROCritical

SolarEdge Error 18xC: DC Arc Fault Detected (AFCI Safety Lockout)

AFCI hardware detected electrical sparking on DC solar strings and safely locked out production to prevent fire.

Error 3x11
PROCritical

SolarEdge Error 3x11: Arc Detection Status Interrupt (AFCI Fault)

Platform arc-detection interrupt (`3x11`) locked out solar output after sensing DC electrical arc signatures.

Error 18x8D
PROHigh

SolarEdge Error 18x8D: AFCI Self-Test Failed (Arc Sensor Hardware Check)

Internal AFCI arc-detection circuit failed its morning wake-up self-verification test.

Error 18xB5
PROCritical

SolarEdge Error 18xB5: Internal DC/AC In-Stage Overvoltage (Hardware RMA)

Internal HD-Wave DC/AC in-stage capacitor bus overvoltage fault requiring warranty inverter replacement.

Error 18xB7
PROCritical

SolarEdge Error 18xB7: Internal DC/AC Out-Stage Overvoltage (Hardware Fault)

HD-Wave output conversion stage registered internal overvoltage (`DC/AC out-stage overvoltage`), requiring inverter replacement.

Error 18xA6
PROCritical

SolarEdge Error 18xA6: Tz Over Voltage (Internal Bus Capacitor Voltage Event)

Internal capacitor bank overvoltage (`Tz Over Voltage`) tripped conversion shutdown from capacitor aging or AC surge.

Error 18x75
DIYMedium

SolarEdge Error 18x75: Overtemp (Internal Thermal Protection Shutdown)

Inverter overheated and temporarily suspended or throttled output due to high ambient temperature or obstructed airflow.

Error 18x37
DIYMedium

SolarEdge Error 18x37: V-Line Max (AC Grid Voltage Too High)

AC line voltage exceeded regional Country Setup ceiling (`V-Line Max`), pausing solar production temporarily.

Error 18x38
DIYMedium

SolarEdge Error 18x38: V-Line Min (AC Grid Voltage Too Low / Brownout)

Incoming utility AC line voltage fell below regional Country Setup minimum (`V-Line Min`), halting export.

Error 18x1D
PROHigh

SolarEdge Error 18x1D: AC Line-to-Neutral Voltage Above Threshold (V_LN Max)

Line-to-Neutral AC voltage exceeded safe threshold from utility overvoltage, country mismatch, or loose neutral reference.

Error 18x1E
DIYMedium

SolarEdge Error 18x1E: AC Line-to-Neutral Voltage Below Threshold (V_LN Min)

Line-to-Neutral AC voltage fell below permissible lower threshold due to tripped breakers, brownouts, or poor neutral connection.

Error 18x20
DIYWarning

SolarEdge Error 18x20: AC Grid Voltage Below Country Limit (Vac Low)

AC output voltage fell below regional utility minimum, pausing export safely.

Error 18x21
DIYWarning

SolarEdge Error 18x21: AC Grid Voltage Above Limit (Vac High / Solar Rise)

AC line voltage exceeded regional overvoltage ceiling during export, pausing solar generation.

Error 2x22
DIYWarning

SolarEdge Error 2x22: AC Grid Frequency Above Limit (F_AC High)

AC line frequency exceeded configured utility ceiling, triggering anti-islanding halt.

Error 2x23
DIYWarning

SolarEdge Error 2x23: AC Grid Frequency Below Limit (F_AC Low)

Measured AC utility frequency dropped beneath regional minimum tolerance, pausing export to protect grid stability.

Error 18x1A
PROCritical

SolarEdge Error 18x1A: AC Grid Voltage Surge Transient (Vac Surge)

Instantaneous AC line voltage transient tripped hardware overvoltage protection, flagging potential surge-arrestor or loose-neutral hazard.

Error 18xC7
PROCritical

SolarEdge Error 18xC7: SafeDC Rapid Shutdown Test Failure (>30V DC)

SafeDC string voltage stayed above 30V DC during rapid shutdown verification on Energy Hub / SetApp inverters.

Error 3x6E
PROWarning

SolarEdge Error 3x6E: RS485 Energy Meter Communication Error

Inverter lost Modbus/RS485 telemetry link to the external Energy Meter, halting battery automation and zero-export control.

Error 3x6A
PROCritical

SolarEdge Error 3x6A: Inverter Remotely Locked / Safety Lock Active

Firmware security or critical safety lockout disabled inverter wake-up until authorized digital unlock via SolarEdge Portal / SetApp.

Error 3xB
PROCritical

SolarEdge Error 3xB: No Country or Grid Profile Configured (Error 44)

Required regional utility Grid Code profile is missing or reset to unconfigured default, blocking AC grid connection.

Error 8x4F
PROCritical

SolarEdge Error 8x4F: Wrong Three-Phase AC Wiring / Phase Rotation (Error 112)

Commercial three-phase inverter detected incorrect phase sequence, missing neutral reference, or AC wiring mismatch at startup.

Error 8x2B
PROCritical

SolarEdge Error 8x2B: Three-Phase Ground / RCD Current Surge Fault

Residual Current Monitoring Unit detected an acute AC/DC earth-leakage spike during live generation, halting inverter output.

Error 2x1A
PROCritical

SolarEdge Error 2x1A: Internal AC Relay Failure (Error 26 / Grid Switch Fault)

Mechanical AC grid isolation relay failed startup self-check (welded shut or failing to latch), halting export safely.

Error 33xD
DIYWarning

SolarEdge Error 33xD: Internal Cooling Fan Failure (Fan Fault)

Cooling fan tachometer reported stalled RPM or open circuit under PWM drive, reducing midday thermal capacity.

Enphase

Microinverters

World leader in microinverter technology (IQ7, IQ8 series) and Envoy communication gateways.

Open Enphase Hub (22)→
Alert: Not Reporting
DIYWarning

Enphase Microinverter Not Reporting (PLC Signal or Breaker Drop)

Enphase IQ Gateway stopped receiving powerline telemetry packets from one or more rooftop microinverters.

Alert: AC Voltage Range
PROWarning

Enphase AC Voltage Out of Range (Grid Overvoltage / Undervoltage)

Microinverter AC output terminals measured grid voltage above or below regional Grid Profile safety bounds.

Alert: AC Frequency Range
PROWarning

Enphase AC Frequency Out of Range (Grid Instability / Battery Shift)

Microinverter sensed AC frequency outside Grid Profile boundaries, or IQ Battery raised frequency during off-grid curtailment.

Error: DC Resistance Low
PROCritical

Enphase DC Resistance Low — Power Off (Latched GFDI Fault)

Latched rooftop DC ground-fault protection permanently disabled an individual microinverter due to insulation leakage.

Alert: Grid Disconnected
DIYCritical

Enphase Grid Disconnected (AC Breaker Open or Utility Outage)

Zero AC utility presence detected at solar branch circuits due to a power outage, open disconnect, or tripped breaker.

Alert: Envoy Offline
DIYInfo

Enphase Envoy / IQ Gateway Not Reporting (Offline From Enlighten)

Enphase IQ Gateway lost internet connection to Enlighten Cloud, halting monitoring telemetry while solar keeps running.

Error: Production Meter
PROWarning

Enphase Production Meter Disconnected (`CT Error / 0W Telemetry`)

Production Current Transformer telemetry failed to match active microinverter generation, causing metering discrepancies.

Error: Consumption Meter
PROWarning

Enphase Consumption Meter Disconnected (`CT Fault / Mirror Graphs`)

Main panel split-core Consumption CTs failed validation, froze home load telemetry, or showed mirrored solar generation.

Error: Hardware Failure
PROCritical

Enphase Microinverter Hardware Failure (Permanent 0W Fault)

An individual rooftop microinverter suffered an unrecoverable internal semiconductor or relay fault and shut down safely.

Alert: Phase Imbalance
PROWarning

Enphase Phase Imbalance Detected (`Voltage or Phase Loss`)

Asymmetrical AC line voltage or current phase loss detected across multi-phase Q-Cable or IQ Gateway sensing rails.

Alert: IQ Battery Comm
PROWarning

Enphase IQ Battery Communication Lost (`Zigbee vs CAN 5P Fault`)

IQ Gateway lost active Zigbee wireless or hardwired CAN Control telemetry link to one or more Enphase IQ Batteries.

Error: System Controller
PROCritical

Enphase IQ System Controller Fault (MID Relay / Microgrid Failure)

Enphase IQ System Controller reported a MID isolation relay, NFT transformer, or control-bus fault.

Alert: Over-Temperature
DIYWarning

Enphase Over-Temperature Shutdown (Thermal Derating / Cutout)

High rooftop or wall-cabinet temperatures drove Enphase microinverters or IQ Gateways into thermal protection.

Alert: AC Frequency Instab
PROWarning

Enphase AC Frequency Instability (`RoCoF / Microgrid Wobble`)

Microinverter anti-islanding algorithms detected rapid AC phase-angle jumps or Rate-of-Change-of-Frequency swings.

Alert: DC Voltage Too Low
PROWarning

Enphase DC Voltage Too Low (`Panel Shading / Sleep / DC Drop`)

Microinverter PV input fell below operational minimum DC start threshold during daytime sunlight.

Error: DC Voltage Too High
PROCritical

Enphase DC Voltage Too High (`PV Voc Exceeded Microinverter Max`)

Rooftop solar module DC voltage exceeded the microinverter's maximum safe input rating, locking operation.

Alert: PLC Interference
DIYInfo

Enphase PLC Noise Interference (Powerline Telemetry Signal Drops)

High-frequency appliance EMI noise interfered with Enphase powerline packets traveling from roof panels to Envoy.

Error: Grid Profile Mismatch
PROCritical

Enphase Grid Profile Mismatch (Wrong Utility Standard Locked)

Microinverter Grid Profile differs from local utility mandate or Envoy site policy, blocking synchronization.

Alert: Rapid Shutdown
PROCritical

Enphase Rapid Shutdown Activated (`NEC 690.12 / RSD Switch Open`)

Rapid Shutdown safety interlock turned off all Enphase solar conversion and lowered conductor voltage to safe levels.

Alert: Cellular Offline
DIYInfo

Enphase IQ Gateway Cellular Failure (LTE-M Modem Offline)

Enphase Envoy USB cellular modem lost carrier connection or lacks active LTE-M signal for cloud uploads.

Alert: Zigbee Interference
DIYWarning

Enphase Zigbee Wireless Interference (`2.4 GHz RSSI / 3T-10T Drop`)

2.4 GHz RF crowding or structural wall attenuation disrupted wireless Zigbee link between IQ Gateway and batteries.

Error: Neutral Lost Fault
PROCritical

Enphase Neutral Lost Fault (`Grid N Open / High N-PE Voltage`)

Critical AC Neutral discontinuity or asymmetrical voltage split detected on Enphase Combiner / IQ Gateway circuits.

Deye

Hybrid Solar Inverter

Global manufacturer of high-efficiency hybrid inverters, low-voltage battery storage, and microinverters.

Open Deye Hub (26)→
Error F01
PROCritical

Deye Error F01: DC Input Polarity Reverse Fault

Inverted positive and negative DC polarity detected across one or more PV MPPT string inputs.

Error F08
PROCritical

Deye Error F08: GFDI Relay Failure / Ground Start Fault

Inverter failed startup GFDI ground-relay verification or detected mismatched grid/neutral earthing configuration.

Error F13
DIYLow

Deye Error F13: Working Mode / Grid Type Change Transition

Inverter paused momentarily to re-initialize power relays after changing Battery, Grid Type, or Operating Mode settings.

Error F14
PROCritical

Deye Error F14: Software DC Overcurrent Fault

DC input current from solar PV strings or DC converter stage exceeded software current limits.

Error F16
PROCritical

Deye Error F16: GFCI / AC Leakage Current Fault (>300mA)

Inverter internal GFCI sensor measured excessive continuous leakage current to ground (>300mA safety limit).

Error F18
PROCritical

Deye Error F18: Hardware AC Overcurrent Fault

Hardware protection circuit detected sudden excessive AC output or grid port current past transistor ratings.

Error F20
PROCritical

Deye Error F20: Hardware DC Overcurrent Fault

Fast analog hardware protection tripped due to excessive DC current surge on the PV or battery converter stage.

Error F22
PROHigh

Deye Error F22: Emergency Stop / Remote Shutdown (Hybrid)

Inverter received an active Emergency Stop / Rapid Shutdown signal on hybrids, or phase/leakage alert on string units.

Error F23
PROHigh

Deye Error F23: GFCI Transient Leakage Current Fault

Internal GFCI/RCMU protection caught a sharp instantaneous step spike in AC/DC earth leakage current.

Error F24
PROCritical

Deye Error F24: DC Insulation Impedance Failure (Riso Fault)

Pre-startup insulation resistance test failed between rooftop PV array conductors and Protective Earth ground.

Error F26
PROCritical

Deye Error F26: DC Busbar Unbalanced (Half-Bus Voltage Fault)

Asymmetry exceeded safety tolerance between upper (+Bus) and lower (-Bus) internal high-voltage DC bus capacitors.

Error F29
PROCritical

Deye Error F29: Parallel CAN Bus Communication Fault

Parallel inverter cluster lost CAN communication synchronization across RJ45 parallel interconnect ports.

Error F30
PROCritical

Deye Error F30: AC Main Contactor / Grid Relay Fault

Internal AC grid transfer relay or contactor failed self-test verification prior to grid synchronization.

Error F33
PROHigh

Deye Error F33: Temperature Sensor Fault / AC Overcurrent (Series Diff)

Internal NTC temperature sensor reading out of bounds on Deye hybrids, or AC overcurrent trip on grid-tied string models.

Error F34
PROHigh

Deye Error F34: AC Overcurrent / Backup Overload Fault

AC output load on the Backup/UPS port exceeded continuous current ratings (or internal comms timeout on select string models).

Error F35
DIYMedium

Deye Error F35: No Utility Grid Detected (AC Loss / Outage)

Inverter sensed complete loss of external AC utility voltage on its Grid input terminals.

Error F41
PROCritical

Deye Error F41: Parallel System Stop (Cascaded Cluster Halt)

Cascade protection stopped parallel-connected hybrid inverters after a sibling inverter faulted (or High Grid Voltage on single string models).

Error F42
PROHigh

Deye Error F42: AC Line Low Voltage (Phase W-U / Undervoltage)

AC utility grid voltage (specifically Line W-U on 3-phase systems) dropped below the configured lower grid protection ceiling.

Error F44
PROHigh

Deye Error F44: AC Line Low Voltage (V-W) / PV Polarity (String Diff)

AC line-to-line voltage across phases V–W fell beneath grid code limits (or PV polarity warning on specific string units).

Error F46
PROHigh

Deye Error F46: Backup Battery Fault / AC Line U-V Low (Series Diff)

Backup battery startup/voltage check error on LV hybrids, MPPT self-check error, or AC Line U-V undervoltage on three-phase units.

Error F47
DIYHigh

Deye Error F47: AC Grid Overfrequency Protection Trip

AC grid or generator port frequency exceeded upper permitted Grid Code ceiling (or EEPROM mismatch on legacy string units).

Error F48
DIYHigh

Deye Error F48: AC Grid Underfrequency Protection Trip

Utility grid or backup generator AC frequency dropped below minimum permissible synchronization floor.

Error F56
PROHigh

Deye Error F56: DC Busbar Voltage Too Low (Hybrid) / Phase Loss (String)

Internal DC bus voltage collapsed below minimum conversion threshold from battery cutoff or dusk solar fade.

Error F58
PROHigh

Deye Error F58: BMS Communication Fault (CAN / RS485)

Hybrid inverter lost closed-loop CAN or RS485 communication with the lithium battery Management System (BMS).

Error F63
PROCritical

Deye Error F63: DC Arc Fault Detection (AFCI) / MCU Safety Fault

AFCI sensor detected high-frequency electrical sparking noise on solar DC strings (or MCU safety/thermal fault on non-AFCI series).

Error F64
PROHigh

Deye Error F64: IGBT Heat Sink High Temperature Fault

Internal IGBT power-stage heatsink exceeded safe operating temperature, triggering thermal shutdown.

SMA Sunny Boy

Solar Inverter

German-engineered high-reliability residential and commercial string inverters.

Open SMA Sunny Boy Hub (24)→
Error 101
DIYWarning

SMA Event 101: Grid Fault — High Grid Voltage / Line-Neutral Peak

Instantaneous AC phase voltage exceeded regional grid-code upper threshold, disconnecting feed-in safely.

Error 102
DIYWarning

SMA Event 102: Grid Fault — Upper Grid Voltage / Impedance Limit

Secondary upper AC grid threshold or rapid utility impedance shift tripped grid-protection disconnect.

Error 202
DIYWarning

SMA Event 202: Grid Fault — Low Grid Voltage or AC Disconnected

AC grid voltage dropped beneath regional lower limit or vanished completely due to open AC breaker or utility outage.

Error 301
DIYWarning

SMA Event 301: 10-Minute Rolling Mean Grid Voltage Exceeded

Ten-minute moving average utility grid voltage exceeded 110% regional statutory limit (~253V), triggering soft disconnection.

Error 3501
PROCritical

SMA Event 3501: Insulation Failure (PV Array Earth Ground Fault)

Measured DC string insulation resistance (`Riso`) dropped below safe safety margin before closing onto utility lines.

Error 3601
PROWarning

SMA Event 3601: High Discharge / Capacitive Leakage Current

Elevated capacitive earth-leakage current exceeded smooth steady thresholds during humid/rainy PV operation.

Error 3701
PROCritical

SMA Event 3701: Residual Current Too High (RCMU Fault Step)

Residual Current Monitoring Unit detected an acute earth-leakage step surge (`>=30 mA`) during live solar operation.

Error 3801
PROCritical

SMA Event 3801: DC Overcurrent Protection (Input A / B Surge)

PV string current exceeded maximum safe MPPT input rating, forcing boost stage protection cutoff.

Error 3901
DIYInfo

SMA Event 3901: Waiting for DC Start Conditions (Low Solar / ESS Off)

Informational status indicating rooftop PV DC voltage or available solar power sits below inverter startup wake threshold.

Error 6400
PROCritical

SMA Event 6400: Self-Diagnosis — Internal Device Disturbance

Internal firmware self-diagnostic check flagged a persistent hardware interference or power-stage anomaly.

Error 6501
DIYWarning

SMA Event 6501: Overtemperature Interior (Thermal Derating / Shutdown)

Internal chassis temperature exceeded maximum thermal ceiling, causing power derating or protective cooling pause.

Error 6601
PROCritical

SMA Event 6601: Self-Diagnosis — Overload / Software Overcurrent

Output stage software or hardware current monitoring tripped overload cutoff following utility step changes or DC-AC imbalance.

Error 6701
PROWarning

SMA Event 6701: Communication Processor Disturbed (CPU Fault)

Internal inverter communication processor experienced a watchdog reset or fault while managing portal and network tasks.

Error 6801
PROCritical

SMA Event 6801: Self-Diagnosis Input A Defective (DC Stage)

Startup self-diagnostics detected a hardware defect on PV String Input A boost or current-sensing stage.

Error 6901
PROCritical

SMA Event 6901: Self-Diagnosis Input B Defective (DC Stage)

Startup self-diagnosis detected an internal hardware defect on PV String Input B boost converter or current sensor.

Error 7001
PROWarning

SMA Event 7001: Interior Temp / Fan Sensor Fault (NTC Error)

Internal cabinet or fan NTC temperature probe reported an open/shorted signal outside calibrated limits.

Error 7101
PROWarning

SMA Event 7101: SD Card or Parameter File Defective

Corrupted FAT32 SD card or unreadable parameter/update file blocked local data logging or firmware loading.

Error 7201
PROCritical

SMA Event 7201: Internal Data Storage Error (EEPROM Fault)

On-board EEPROM or flash memory failed internal write verification or checksum reads for inverter parameters.

Error 7301
PROWarning

SMA Event 7301: Sub-Module Firmware Update Failed

Multi-stage firmware update failed to flash a sub-module inside the inverter cleanly.

Error 7401
PROCritical

SMA Event 7401: Varistor / DC Surge Protector Defective

Internal thermally monitored DC varistor surge suppressor opened safely after absorbing a rooftop overvoltage transient.

Error 7501
DIYWarning

SMA Event 7501: Interior Cooling Fan Failure or Blocked Airflow

Cooling fan tachometer reported stalled blades or zero RPM under PWM drive, reducing midday heat tolerance.

Error 7601
PROCritical

SMA Event 7601: Internal IPC Communication Error

Failed internal IPC serial messaging between main power DSP and supervisory control boards halted system coordination.

Error 7701
PROCritical

SMA Event 7701: Self-Diagnosis Power Device Malfunction

Core power-stage hardware failed morning internal self-diagnosis, locking inverter synchronization safely offline.

Error 7801
PROCritical

SMA Event 7801: DC Surge Arrestor Fault (Type II SPD Tripped)

Internal Type II DC Surge Protection Device cartridge sacrificed safely during an overvoltage surge and requires replacement.

Daikin Altherma

Air-to-Water Heat Pump

Europe's leading domestic heating and heat pump systems.

Open Daikin Altherma Hub (24)→
Fault A1
PROCritical

Daikin Altherma Fault A1: Indoor Unit PCB / EEPROM Failure

Indoor Hydrobox or indoor fan-coil control PCB failed internal EEPROM checksum verification or logic diagnostics.

Fault A6
PROCritical

Daikin Fault A6: Indoor Fan Motor Lock / Blower Overload

Indoor blower fan motor locked or failed RPM feedback diagnostics, halting airflow and heating/cooling output.

Fault C4
PROWarning

Daikin Altherma Fault C4: Heat Exchanger Thermistor Abnormality

Indoor plate/evaporator heat exchanger thermistor (`R2T`) reported out-of-range open or shorted resistance.

Fault C9
PROWarning

Daikin Fault C9: Suction / Return Air Thermistor Failure

Indoor return/suction air thermistor (`R1T`) drifted outside valid resistance range, disabling temperature control.

Fault E1
PROCritical

Daikin Altherma Fault E1: Outdoor Unit PCB Defect / EEPROM Error

Outdoor inverter control PCB failed EEPROM checksum or internal microprocessor health diagnostics.

Fault E3
PROCritical

Daikin Altherma Fault E3: High Pressure Switch Actuated (HPS Trip)

Refrigerant discharge pressure exceeded critical safety cut-off threshold, opening high-pressure protection.

Fault E4
PROCritical

Daikin Altherma Fault E4: Low Pressure Protection Actuated

Suction refrigerant pressure dropped below protective threshold due to low refrigerant charge, frozen outdoor coil, or blocked EEV.

Fault E7
PROCritical

Daikin Altherma Fault E7: Outdoor Fan Motor Lock / Failure

Outdoor unit brushless DC condenser fan locked mechanically or tripped overcurrent sensing.

Fault H9
PROWarning

Daikin Altherma Fault H9: Outdoor Ambient Air Thermistor Fault

Outdoor ambient air NTC thermistor (`R1T`) mounted behind rear condenser fins failed out of valid ohmic range.

Fault J3
PROCritical

Daikin Altherma Fault J3: Discharge Pipe Thermistor Abnormality

Outdoor compressor discharge pipe thermistor failed high-temperature insulation or continuity checks.

Fault J6
PROWarning

Daikin Altherma Fault J6: Outdoor Heat Exchanger Coil Sensor Fault

Outdoor condenser/evaporator coil thermistor (`R4T`) failed out of ohmic limits, disrupting winter defrost sensing.

Fault L4
PROCritical

Daikin Altherma Fault L4: Inverter Heatsink Overheating (`>93°C`)

Outdoor inverter power-module aluminum heatsink overheated past safe ceiling, shutting down compressor output.

Fault L5
PROCritical

Daikin Altherma Fault L5: Instantaneous Compressor Overcurrent

Outdoor inverter IPM bridge sensed severe compressor output overcurrent, halting drive immediately.

Fault P4
PROCritical

Daikin Altherma Fault P4: Inverter Radiator Fin Thermistor Fault

Outdoor inverter heatsink temperature sensor failed electrical continuity/range diagnostics on control board.

Fault U0
PROCritical

Daikin Altherma Fault U0: Insufficient Refrigerant / Gas Shortage

Thermodynamic temperature and pressure spreads detected insufficient R32/R410A refrigerant charge.

Fault U2
PROCritical

Daikin Altherma Fault U2: Power Supply / DC Bus Voltage Fault

Abnormal AC supply voltage, phase imbalance, or failed internal high-voltage DC link capacitor charge detected.

Fault U4
PROCritical

Daikin Altherma Fault U4: Indoor-to-Outdoor Comms Fault

Indoor Hydrobox controller failed to receive communication replies from the outdoor condensing unit.

Fault U5
PROWarning

Daikin Altherma Fault U5: User Controller Transmission Fault

Broken serial communication or address conflict between indoor unit main PCB and wired remote wall thermostat.

Fault UA
PROCritical

Daikin Altherma Fault UA: Indoor/Outdoor Combination Mismatch

Indoor and outdoor unit series, capacity ratings, or spare PCB jumper configurations are mismatched.

Fault 7H
PROCritical

Daikin Altherma Fault 7H: Water Flow Problem / Blocked Circulation

Insufficient heating water circulation flow measured through Hydrobox plate heat exchanger, halting heating.

Fault 8H
PROCritical

Daikin Altherma Fault 8H: High Outlet Water Temp / Heater Cutout

Hydrobox outlet water overheated beyond safe thermal limits or tripped electric backup heater thermal safety switch.

Fault 80
PROWarning

Daikin Altherma Fault 80: Entering Water Thermistor (`R4T/R2T`) Fault

Hydrobox Entering (Return) Water NTC thermistor reported invalid open or shorted resistance telemetry.

Fault 81
PROWarning

Daikin Altherma Fault 81: Leaving Water Thermistor (`R1T/Outlet`) Fault

Hydrobox Leaving (Flow) Water NTC thermistor reported out-of-range open or shorted resistance telemetry.

Fault 89
PROCritical

Daikin Altherma Fault 89: Plate Heat Exchanger Freeze Protection

Indoor brazed-plate heat exchanger temperature dropped toward freezing point, halting system to prevent plate rupture.

Fronius

Solar Inverter

Austrian engineered premium solar string inverters (Symo, Primo, Galvo, and Gen24 Plus series) renowned for SnapINverter modular architecture.

Open Fronius Hub (22)→
State 102
DIYMedium

Fronius State 102: AC Grid Voltage Too High (Overvoltage Trip)

AC grid voltage exceeded upper statutory protection limit, pausing solar feed-in to protect home appliances and grid stability.

State 103
DIYMedium

Fronius State 103: AC Grid Voltage Too Low (Undervoltage Trip)

AC grid voltage dipped below lower statutory safety threshold, halting export until utility voltage stabilizes.

State 105
DIYMedium

Fronius State 105: AC Grid Frequency Too High (Overfrequency Trip)

Utility grid or backup generator AC frequency exceeded upper permitted limit, pausing solar feed-in.

State 107
DIYMedium

Fronius State 107: AC Grid Outside Permissible Limits / No Grid Detected

AC grid missing or combined grid parameters out of bounds while inverter attempts synchronization.

State 240
PROCritical

Fronius State 240: DC Arc Detected (AFCI Safety Shutdown)

AFCI safety hardware detected dangerous DC arcing on solar string wiring and locked out production.

State 301
DIYLow

Fronius State 301: AC Overcurrent Transient (Brief Feed-In Pause)

Short-term overcurrent transient on the AC side caused a temporary protective pause and automatic restart.

State 303
DIYMedium

Fronius State 303: DC-AC Power Stage Set Heatsink Over-Temperature

DC-AC power stage heatsink overheated due to restricted airflow, stalled cooling fan, or extreme sun exposure.

State 304
DIYMedium

Fronius State 304: Internal / DC-DC Board Over-Temperature

Internal cabinet or DC-DC converter board temperature rose above safe threshold due to trapped heat or fan stoppage.

State 307
DIYLow

Fronius State 307: DC Low Input Voltage (PV Array Under Start Threshold)

Solar DC string voltage fell below inverter startup minimum—normal at dawn/dusk or signal of OFF DC switch in midday.

State 401
PROHigh

Fronius State 401: No Communication with Power Stage Set

Internal digital communication failed between control brain board and power stage set.

State 443
PROHigh

Fronius State 443: Intermediate Circuit (DC-Link) Voltage Fault

Internal DC-link intermediate circuit bus voltage dropped too low or became unbalanced between positive and negative legs.

State 457
PROCritical

Fronius State 457: Grid Relay Sticking / High Neutral-to-Ground Voltage

Safety grid relay failed open/close self-test or neutral-to-ground voltage exceeded safety threshold.

State 474
PROCritical

Fronius State 474: RCMU Sensor Defective (Residual Current Unit Fault)

Internal Residual Current Monitoring Unit (RCMU) safety sensor failed calibration self-test or malfunctioned.

State 475
PROCritical

Fronius State 475: Solar Panel Ground Fault (Low Insulation Resistance)

Insulation resistance between DC solar strings and earth dropped below safety floor due to moisture ingress or cable damage.

State 509
DIYLow

Fronius State 509: No Solar Feed-In for 24 Hours (Production Pause Alert)

Informational notice stating zero energy has been fed into the AC grid for 24 consecutive hours.

State 516
PROMedium

Fronius State 516: Storage Unit Communication Fault / Power Stage Error Limit

Communication error with connected battery storage unit / filter, or SnapINverter daily power-stage logging warning.

State 517
DIYLow

Fronius State 517: Power Limitation / Thermal Derating Active

Inverter proactively lowered maximum AC wattage output to prevent overheating under hot conditions or restricted cooling.

State 558
PROMedium

Fronius State 558: Functional Incompatibility (Internal PC Board / Firmware Mismatch)

One or more internal inverter PC boards are running incompatible firmware revisions or mismatched hardware versions.

State 560
DIYLow

Fronius State 560: Power Reduction Due to Over-Frequency (Grid Support P(f))

Inverter actively curtailed output power to help stabilize grid frequency above standard over-frequency start point.

State 567
DIYLow

Fronius State 567: Grid-Voltage Dependent Power Reduction (Volt-Watt Mode)

Inverter scaled back export power under Volt-Watt rules because local grid voltage rose high.

State 705
PROMedium

Fronius State 705: Inverter Number Conflict on Solar.Net Ring

Multiple inverters daisy-chained onto a Fronius Solar.Net loop share duplicate device numbers, colliding on monitoring telemetry.

State 731
DIYLow

Fronius State 731: USB Flash Drive Initialization / Read Error

USB flash drive plugged into inverter failed initialization during logging or local firmware update.

Victron Energy

Off-Grid & Battery Inverters

Dutch manufacturer of professional off-grid power, marine, and mobile battery inverter/chargers (MultiPlus, Quattro, SmartSolar MPPT, Cerbo GX).

Open Victron Energy Hub (12)→
Error #20
DIYMedium

Victron SmartSolar Error #20: Maximum Bulk Time Exceeded

MPPT controller stayed inside the Bulk charge stage past its legacy 10-hour timer threshold without attaining absorption target voltage.

Error #21
PROHigh

Victron SmartSolar Error #21: Internal Current Sensor Issue

MPPT controller measured impossible zero-offset or out-of-range internal DC current calibration values.

Error #26
PROCritical

Victron SmartSolar Error #26: Terminal Overheated

MPPT power terminal temperature sensor detected dangerous overheating at the PV or battery terminal connections.

Error #27
PROCritical

Victron SmartSolar Error #27: Charger Output Short Circuit

MPPT detected a short circuit or massive surge current spike on its battery output terminals.

Error #34
PROCritical

Victron SmartSolar Error #34: PV Input Over-Current Shutdown

Solar PV input current exceeded the controller's maximum allowed input threshold or triggered an internal input fault.

Error #38
PROCritical

Victron SmartSolar Error #38: PV Input Shutdown (Battery Over-Voltage)

MPPT latched its PV input shutdown circuit after detecting excessive battery over-voltage or sudden load/BMS disconnect overshoot.

Error #68
DIYMedium

Victron SmartSolar Error #68: Network Misconfigured

MPPT controller received conflicting battery/temperature data from multiple Victron network protocols simultaneously.

Error #116
PROCritical

Victron MPPT Error #116: Factory Calibration Data Lost

Internal non-volatile calibration data corrupted or missing inside the MPPT microcontroller.

VE.Bus Error 2
PROCritical

Victron MultiPlus VE.Bus Error 2: Mixed Old & New MK2 Protocols

Mixed old and new MK2 communication protocols detected across interconnected MultiPlus, Quattro, or VE.Bus interface devices.

VE.Bus Error 8
PROCritical

Victron MultiPlus VE.Bus Error 8: Ground Relay Test Failed

Inverter/charger failed its internal safety ground relay self-test on startup or grid connection.

Low Battery Alarm
DIYHigh

Victron MultiPlus: Low Battery Pre-Alarm & Dynamic Cutoff

DC terminal voltage at the MultiPlus dropped below the low-battery pre-alarm or dynamic shutdown threshold.

Overload Alarm
DIYHigh

Victron MultiPlus: Inverter Overload Pre-Alarm & Shutdown

AC output load on AC-Out-1 exceeded the MultiPlus/Quattro continuous power rating or peak surge duration.

Sungrow

Hybrid Solar Inverter

World-leading manufacturer of high-efficiency utility, commercial, and residential hybrid solar inverters (SG and SH series).

Open Sungrow Hub (16)→
Fault 003
DIYHigh

Sungrow Fault 003: Grid Transient Overvoltage Protection Trip

Instantaneous AC grid overvoltage exceeded Sungrow Stage I protection limits, forcing a protective grid relay disconnect until line voltage drops back within statutory range.

Fault 008
DIYHigh

Sungrow Fault 008: AC Grid Over-Frequency Protection Trip

AC grid frequency exceeded the permissible upper safety limit, causing the Sungrow inverter to disconnect export power until grid frequency stabilizes.

Fault 011
PROCritical

Sungrow Fault 011: DC Current Injection High on AC Output

Excessive DC current component was detected on the inverter AC output lines, indicating asymmetric bridge switching, current-sensor drift, or internal IGBT stress.

Fault 012
PROCritical

Sungrow Fault 012: Excess Leakage Current (Residual Current Fault)

Differential current leakage to earth exceeded IEC 62109-2 safety thresholds, disconnecting the Sungrow inverter to prevent electric shock and rooftop fire hazards.

Fault 014
DIYHigh

Sungrow Fault 014: 10-Minute Average Grid Overvoltage Trip

The rolling 10-minute average AC voltage at the Sungrow grid terminals exceeded regulatory limits, forcing a temporary grid export pause.

Fault 015
DIYHigh

Sungrow Fault 015: High Grid Overvoltage (Stage II Trip)

Grid AC voltage breached the higher Stage II overvoltage protection ceiling, prompting immediate safety disconnection to protect connected appliances and power electronics.

Fault 023
PROCritical

Sungrow Fault 023: PV3 Input Overcurrent / PV Configuration Mode Fault

Abnormal DC input current on PV string channel 3 or an incompatible PV input configuration mode change forced a protective MPPT shutdown.

Fault 024
PROCritical

Sungrow Fault 024: PV4 Input Overcurrent / Neutral Point Voltage Deviation

Fault 024 flags abnormal current on PV string 4 or an internal neutral-point voltage asymmetry across the DC/AC power bridge.

Fault 036
DIYMedium

Sungrow Fault 036: Radiator (Heatsink) Over-Temperature Protection

Excessive heat buildup on the inverter's rear cooling radiator triggered thermal derating or temporary shutdown until heatsink temperatures decline.

Fault 037
DIYMedium

Sungrow Fault 037: Inverter Internal Over-Temperature Protection

Internal compartment temperature exceeded Sungrow hardware limits due to poor ambient ventilation, direct heat exposure, or blocked external air circulation.

Fault 039
PROCritical

Sungrow Fault 039: Low System Insulation Resistance (ISO Fault)

Pre-startup insulation testing measured DC PV-to-earth resistance below minimum IEC safety limits, locking out grid connection to prevent shock or arc fires.

Fault 071
PROHigh

Sungrow Fault 071: AC-Side Surge Protection Device (SPD) Alarm

The AC-side surge arrester (SPD) monitoring circuit detected a tripped, degraded, or disconnected varistor cartridge following a transient voltage spike.

Fault 072
PROHigh

Sungrow Fault 072: DC-Side Surge Protection Device (SPD) Alarm

The PV DC-side surge protection module tripped after absorbing a voltage surge, or internal DC bus voltage exceeded RMS hardware bounds.

Fault 073
PROCritical

Sungrow Fault 073: String DC Fuse Blown / Internal Bus Instantaneous Overvoltage

An internal string DC fuse ruptured due to string overcurrent/shorting, or internal DC bus voltage spiked past instantaneous protection limits.

Fault 090
PROCritical

Sungrow Fault 090: Parallel Synchronous Signal / Control Board Fault

Parallel inverter synchronization timing failed or an internal auxiliary control voltage rail dropped out of tolerance, halting operation.

Fault 105
PROHigh

Sungrow Fault 105: SPI Auto-Test / Grid Protection Self-Check Failure

The automated pre-connection grid protection relay and trip-time verification routine timed out or failed, blocking utility grid export.

Mitsubishi Electric Ecodan

Air-to-Water Heat Pump

Market-leading Japanese air-source and water-source residential heat pumps featuring Zubadan flash-injection technology.

Open Mitsubishi Electric Ecodan Hub (15)→
Fault Code L5
PROHigh

Mitsubishi Ecodan Fault L5: Water Thermistor Open or Short

FTC control board measured an out-of-range voltage, unplugged harness, or short on a THW water thermistor.

Fault Code L6
PROCritical

Mitsubishi Ecodan Fault L6: Circulation Water Freeze Protection

Primary heating water temperature inside the plate heat exchanger dropped toward freezing due to stalled or restricted circulation.

Fault Code L8
PROHigh

Mitsubishi Ecodan Fault L8: Heating Error (No Water Temperature Rise)

FTC detected negligible water temperature gain between THW1 flow and THW2 return despite sustained heating demand.

Fault Code L9
PROHigh

Mitsubishi Ecodan Fault L9: Low Primary Circuit Water Flow

Inline flow sensor measured heating loop circulation below safe minimum volume across the plate heat exchanger.

Fault Code U1
PROCritical

Mitsubishi Ecodan Fault U1: High Pressure Switch Tripped (63H)

Refrigerant discharge pressure exceeded high-pressure safety switch 63H limits, stopping the outdoor compressor.

Fault Code U2
PROCritical

Mitsubishi Ecodan Fault U2: Abnormal Compressor Discharge Temp

Discharge thermistor TH4 detected overheating compressor outlet gas above safe thermal limits.

Fault Code U5
PROCritical

Mitsubishi Ecodan Fault U5: Inverter Heat Sink Overheat Protection

Outdoor inverter heatsink thermistor (TH8) exceeded safe operating heat, tripping power-module thermal protection.

Fault Code P2
PROHigh

Mitsubishi Ecodan Fault P2: Liquid Refrigerant Thermistor (TH2)

Indoor liquid refrigerant pipe thermistor TH2 measured an electrical open or short circuit.

Fault Code P8
PROHigh

Mitsubishi Ecodan Fault P8: Plate Heat Exchanger Temp / Pipe Error

Refrigerant pipe temperature failed expected change across the plate heat exchanger during active heating or defrost.

Fault Code E0
PROMedium

Mitsubishi Ecodan Fault E0: Wired Remote Controller Transmission Error

Wired remote controller transmission failed across the two-wire communication link to the indoor FTC board.

Fault Code E1
PROCritical

Mitsubishi Ecodan Fault E1: Controller Board / Main PCB Fault

Internal remote controller PCB or FTC logic board failed electronic self-diagnostics or reception loopbacks.

Fault Code E6
PROCritical

Mitsubishi Ecodan Fault E6: Indoor / Outdoor Communication Error

Indoor unit failed to receive valid data packets from the outdoor unit across the S1-S2-S3 communication link.

Fault Code E9
PROCritical

Mitsubishi Ecodan Fault E9: Indoor / Outdoor Transmission Failure

Outdoor unit failed to transmit valid replies back to indoor FTC across S1-S2-S3 interconnecting wiring.

Fault Code J0
PROHigh

Mitsubishi Ecodan Fault J0: FTC & Wireless Receiver Comm Fault

FTC main control board stopped receiving wired communication frames from the wireless receiver box (PAR-WR51R) for over 1 minute.

Fault Code J5
DIYMedium

Mitsubishi Ecodan Fault J5: Wireless Thermostat Communication Fault

Wireless receiver lost RF radio link from the battery-powered wireless thermostat assigned to zone address 5.