Fronius State 307: DC Low Input Voltage (PV Array Under Start Threshold)
Affected Models: Fronius Primo, Symo, Eco, Galvo & GEN24 Plus
⚡ Quick Engineering Answer
Fronius • State 307Fronius State 307 indicates that incoming DC voltage from your solar panels is below the minimum start/operation threshold (typically ~80V–200V DC depending on model). This is completely normal every morning at dawn, dusk, or under thick snow—it only signals a DC isolator OFF switch or disconnected string if seen continuously at bright midday.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- Solar DC string voltage fell below inverter startup minimum—normal at dawn/dusk or signal of OFF DC switch in midday.
- Trigger Threshold
- PV DC string voltage < minimum startup ceiling (~80V–200V depending on platform)
- Recovery Window
- Auto-clears smoothly within seconds once morning sunshine or DC switch closure restores string voltage
- Subsystem Affected
- PV DC Array Input & MPPT Startup Stage
- Warranty Outlook
- Normal twilight status / external DC switch OFF / panel string issue (rarely hardware failure)
How Fronius State 307 Triggers
Grid-tied and hybrid Fronius inverters shut their DC-AC conversion bridge down every evening when twilight irradiance stops sustaining minimum operating voltage (U_dc_start), saving standby energy overnight. Fronius State 307 (Low PV voltage / DC voltage too low) is purely an informational operating state printed whenever PV string voltage sits under that start threshold.
Consequently, spotting State 307 at 6:00 AM, dusk, during thick fog, or under heavy rooftop snow means your inverter is working 100% normally. Diagnosis is needed ONLY if State 307 locks the inverter in standby through bright midday sunshine, pointing directly to a turned-off bottom DC rotary disconnector, heavy panel shading, snow cover, or a disconnected/open rooftop MC4 string loop.
🔀 Hardware & Series Differences
Often accompanied by State 509 if DC rotary disconnector stayed OFF past 24 hours.
Higher three-phase DC link requires higher startup Voc than single-phase models during winter dawn.
🔍 Observable Symptoms
- •State 307 displays cleanly every early morning at sunrise and late evening around sunset (100% normal).
- •Appears at noon exclusively under heavy winter snow accumulation covering solar panels.
- •If seen continuously in clear midday sun: 0W output and rotary black DC switch found in OFF (0) position.
- •Paired with State 509 ('No feed-in for 24h') if DC isolation stayed off all day.
⚙️ Ranked Root Causes
Panels naturally drop beneath 80V–200V minimum starting voltage in darkness or heavy shade.
Leaves inverter AC-powered while disconnecting incoming PV array completely.
One unlatched rooftop MC4 connector drops string Voc cleanly to 0V during bright sun.
Third-party rapid shutdown (RSD) stays tripped open if AC transmitter lost power.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightEarly morning, dusk, heavy storms, or snow on panels make State 307 completely expected.
Confirm the integrated rotary DC switch under the Fronius housing and external wall DC isolators sit cleanly ON.
Read reported DC voltage on MPPT1 and MPPT2 safely from screen/app during sunny noon.
Safe External Scope: Do Not Open Covers or Probe Terminals
All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.
🔧 Interactive Step-by-Step Diagnostic Checklist
Confirm Time of Day, Snow Cover & DC Switch Position
Rule out normal dawn/dusk light levels or snow-covered roof arrays first; if shining full sun at noon, look under the inverter and verify the black rotary DC switch sits firmly at ON (I).
Inspect Rapid Shutdown Transmitter Status & String Readout
If Udc reads near 0V despite bright noon sun and ON switches, note whether external rapid-shutdown (RSD) power supplies in the garage appear lit (North America) and book a solar electrician.
Document Daylight DC Voltages for String Testing
Capture a clear photo of Udc1/Udc2 measurements on screen around sunny midday along with panel layout details before calling your installer for rooftop fuse or connector repairs.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing State 307? Copy this structured engineering summary for your installer or OEM RMA ticket.
📋 Homeowner Preparation & Read-Only Access Needed
No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:
- ✓Fronius LCD / Solar.web MPPT Voltage View
- ✓External DC Switch Access
Recommended Diagnostic Tools & Replacement Parts
Recommended external inspection gear for Fronius State 307
❓ Frequently Asked Questions
Why does my Fronius email me State 307 every morning and evening?
You can mute informational low-light warnings in Solar.web—State 307 simply logs every sunrise and sunset as array sunlight crosses startup voltage cleanly.
State 307 is still showing at 12:30 PM on a cloudless sunny day—what should I check?
First look beneath the inverter to verify the black DC rotary isolator hasn't been turned OFF (0); if it is ON, a rooftop string fuse, MC4 plug, or isolator contact likely opened.
Will snow on solar panels cause State 307?
Yes—opaque snow blocks light from reaching solar cells, holding array voltage near zero until melting exposes modules.
Related Fronius Fault Codes
Informational notice stating zero energy has been fed into the AC grid for 24 consecutive hours.
AC grid missing or combined grid parameters out of bounds while inverter attempts synchronization.
Insulation resistance between DC solar strings and earth dropped below safety floor due to moisture ingress or cable damage.
AFCI safety hardware detected dangerous DC arcing on solar string wiring and locked out production.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).