Fronius State 307: DC Low Input Voltage (PV Array Under Start Threshold)

Affected Models: Fronius Primo, Symo, Eco, Galvo & GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Normal Dawn/Switch) - $250 (String Connector Service)
Warranty may cover parts
Diag / Fix Time
5 - 60 mins
DC Solar Array Input & Startup

⚡ Quick Engineering Answer

Fronius • State 307

Fronius State 307 indicates that incoming DC voltage from your solar panels is below the minimum start/operation threshold (typically ~80V–200V DC depending on model). This is completely normal every morning at dawn, dusk, or under thick snow—it only signals a DC isolator OFF switch or disconnected string if seen continuously at bright midday.

Recovery Behavior:Normal overnight/twilight behavior that clears automatically every morning once sunlight raises solar string voltage.
SCHEMATIC // Fronius State 307 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 307: PV Array, AFCI & DC Boost Stage System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PV Array, AFCI & DC Boost Stage
Signal / Power Path
Roof Strings / MC4 / Optimizers -> DC Isolator & MPPT
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Solar DC string voltage fell below inverter startup minimum—normal at dawn/dusk or signal of OFF DC switch in midday.
Trigger Threshold
PV DC string voltage < minimum startup ceiling (~80V–200V depending on platform)
Recovery Window
Auto-clears smoothly within seconds once morning sunshine or DC switch closure restores string voltage
Subsystem Affected
PV DC Array Input & MPPT Startup Stage
Warranty Outlook
Normal twilight status / external DC switch OFF / panel string issue (rarely hardware failure)

How Fronius State 307 Triggers

Grid-tied and hybrid Fronius inverters shut their DC-AC conversion bridge down every evening when twilight irradiance stops sustaining minimum operating voltage (U_dc_start), saving standby energy overnight. Fronius State 307 (Low PV voltage / DC voltage too low) is purely an informational operating state printed whenever PV string voltage sits under that start threshold.

Consequently, spotting State 307 at 6:00 AM, dusk, during thick fog, or under heavy rooftop snow means your inverter is working 100% normally. Diagnosis is needed ONLY if State 307 locks the inverter in standby through bright midday sunshine, pointing directly to a turned-off bottom DC rotary disconnector, heavy panel shading, snow cover, or a disconnected/open rooftop MC4 string loop.

🔀 Hardware & Series Differences

Fronius Primo & GEN24 Single-Phase
DC PV input sitting under ~80V startup voltage (completely normal in dark/twilight)

Often accompanied by State 509 if DC rotary disconnector stayed OFF past 24 hours.

Fronius Symo & Eco Three-Phase
PV input voltage below ~200V start voltage threshold on three-phase bus

Higher three-phase DC link requires higher startup Voc than single-phase models during winter dawn.

🔍 Observable Symptoms

  • •State 307 displays cleanly every early morning at sunrise and late evening around sunset (100% normal).
  • •Appears at noon exclusively under heavy winter snow accumulation covering solar panels.
  • •If seen continuously in clear midday sun: 0W output and rotary black DC switch found in OFF (0) position.
  • •Paired with State 509 ('No feed-in for 24h') if DC isolation stayed off all day.

⚙️ Ranked Root Causes

Normal dawn, dusk, storm clouds, or rooftop snow accumulation covering modulesHigh

Panels naturally drop beneath 80V–200V minimum starting voltage in darkness or heavy shade.

Bottom black DC Disconnector dial on inverter or rooftop DC switch switched to OFF (0)High

Leaves inverter AC-powered while disconnecting incoming PV array completely.

Open string connection, blown DC string fuse, or severely under-sized series panel countMedium

One unlatched rooftop MC4 connector drops string Voc cleanly to 0V during bright sun.

Dead internal DC input voltage sensor or rapid shutdown transmitter stuck OFFLow

Third-party rapid shutdown (RSD) stays tripped open if AC transmitter lost power.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Time of Day & Weather Outside

Early morning, dusk, heavy storms, or snow on panels make State 307 completely expected.

2CHECK / VERIFY
Verify Bottom Black DC Disconnector Dial Reads ON (I)

Confirm the integrated rotary DC switch under the Fronius housing and external wall DC isolators sit cleanly ON.

3CHECK / VERIFY
Check Udc (DC Volts) on LCD Info / WebUI During Sun

Read reported DC voltage on MPPT1 and MPPT2 safely from screen/app during sunny noon.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Time of Day, Snow Cover & DC Switch Position

Homeowner Safe

Rule out normal dawn/dusk light levels or snow-covered roof arrays first; if shining full sun at noon, look under the inverter and verify the black rotary DC switch sits firmly at ON (I).

✓ Expected ResultImmediately identifies normal low-light states or accidentally switched-off DC isolators.
→ If Fault PersistsCheck Fronius WebUI or front LCD Info menu for exact Udc1/Udc2 voltage numbers.
2

Inspect Rapid Shutdown Transmitter Status & String Readout

Homeowner Safe

If Udc reads near 0V despite bright noon sun and ON switches, note whether external rapid-shutdown (RSD) power supplies in the garage appear lit (North America) and book a solar electrician.

✓ Expected ResultSeparates tripped external RSD controllers from open roof strings cleanly.
→ If Fault PersistsNever open DC junction boxes or climb roofs; call a certified solar technician.
3

Document Daylight DC Voltages for String Testing

Homeowner Safe

Capture a clear photo of Udc1/Udc2 measurements on screen around sunny midday along with panel layout details before calling your installer for rooftop fuse or connector repairs.

✓ Expected ResultLets technicians immediately determine whether one string or the entire array opened.
→ If Fault PersistsTurn bottom DC switch OFF only if electrical damage or odor is noticed.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 307? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Fronius LCD / Solar.web MPPT Voltage View
  • ✓External DC Switch Access
🧰

Recommended Diagnostic Tools & Replacement Parts

Recommended external inspection gear for Fronius State 307

DIY Safe Gear
🔧 Physical Tool / Supply
Ground-Level Binoculars (Safe Snow/Shade Inspection)
Verified physical tools only (no apps or portal items linked).External Amazon search links open in a new tab.

❓ Frequently Asked Questions

Why does my Fronius email me State 307 every morning and evening?

You can mute informational low-light warnings in Solar.web—State 307 simply logs every sunrise and sunset as array sunlight crosses startup voltage cleanly.

State 307 is still showing at 12:30 PM on a cloudless sunny day—what should I check?

First look beneath the inverter to verify the black DC rotary isolator hasn't been turned OFF (0); if it is ON, a rooftop string fuse, MC4 plug, or isolator contact likely opened.

Will snow on solar panels cause State 307?

Yes—opaque snow blocks light from reaching solar cells, holding array voltage near zero until melting exposes modules.

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians