Fronius State 107: AC Grid Outside Permissible Limits / No Grid Detected

Affected Models: Fronius Primo, Symo, Eco, Galvo & GEN24 / GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Reset Breaker) - $260 (Switch / AC Repair)
Warranty may cover parts
Diag / Fix Time
15 - 60 mins
AC Grid Connection & Anti-Islanding

⚡ Quick Engineering Answer

Fronius • State 107

Fronius State 107 signals that the inverter cannot detect a stable utility AC grid while attempting startup synchronization—most commonly caused by a neighborhood power outage, a tripped Solar Supply Main Switch in the meter box, or an external AC isolator left OFF. Check switchboard breakers first before calling a technician.

Recovery Behavior:Auto-clears once clean AC grid power returns through closed main switchboard breakers and grid timers finish.
SCHEMATIC // Fronius State 107 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 107: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
AC grid missing or combined grid parameters out of bounds while inverter attempts synchronization.
Trigger Threshold
Zero AC utility voltage detected or sustained combined voltage/frequency disturbance during sync check
Recovery Window
Auto-clears 60–180s once steady mains AC power is restored
Subsystem Affected
AC Main Contactor & Utility Detection Input
Warranty Outlook
External breaker trip, utility outage, or loose external AC switch (not hardware failure unless breakers stay ON)

How Fronius State 107 Triggers

Unlike solar off-grid machines, standard Fronius grid-tied systems require a clean incoming utility reference signal to synchronize sine waves safely. Fronius State 107 (AC grid outside permissible limits / No AC Grid detected) logs when AC terminals either read zero voltage completely or register unstable combined voltage/frequency glitches during startup.

This is among the most routine Fronius service calls, frequently resolved cleanly inside the homeowner's electrical distribution board when an RCD/RCBO or dedicated Solar Supply breaker trips quietly during lightning storms or heavy appliance faults—leaving rooftop panels sunlit while no AC feed reaches the inverter.

🔀 Hardware & Series Differences

Fronius SnapINverter (Primo / Symo)
State 107 shown on LCD alongside steady orange LED while awaiting valid AC grid connection

Often simply indicates AC isolator switch or main switchboard solar MCB tripped OFF.

Fronius GEN24 / GEN24 Plus
Event 107 triggered upon utility grid loss; PV Point / Full Backup ports switch to emergency backup if configured

Verify automated transfer switch (ATS / Backup Switch) status on battery backup installations.

🔍 Observable Symptoms

  • •Inverter fan sits idle in bright sunshine displaying State 107 on LCD or Solar.web.
  • •AC circuit breaker labeled 'Solar Main Switch' in meter board found flipped OFF.
  • •Occurs immediately following local utility blackouts or lightning thunderstorms.
  • •Zero watts fed into grid despite strong DC string voltages on diagnostics page.

⚙️ Ranked Root Causes

Dedicated Solar Supply Main Switch (AC breaker) or RCD tripped in switchboardHigh

Lightning surges or damp outdoor AC conduits trip earth-leakage RCDs while keeping house lights on.

Active regional utility outage or blown street pole fuseHigh

Inverter remains safely in anti-islanding lockout until utility power returns.

Exterior weatherproof AC isolator dial rotated OFF accidentallyMedium

Gardener, painter, or maintenance worker switched rotary AC isolator off near inverter.

Loose AC terminal lug or defective internal AC voltage sensing circuitLow

Heat-damaged AC plug inside inverter bottom bay disconnects one phase physically.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Inspect Switchboard Solar MCB / RCD & Exterior AC Isolator

Check meter box for tripped breakers labeled Solar Supply and confirm rotary AC switch reads ON.

2DISCHARGE / WAIT
Confirm Household Grid Power & Wait 5 Minutes

Ensure utility electricity is present inside home outlets and allow startup test timers to finish.

3DISCHARGE / WAIT
Follow Full Cold Reset If Breaker Resets Cleanly

Switch Solar AC off -> DC off -> wait 3 minutes until screen fades -> DC on -> AC on.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Check Main Switchboard Solar Breaker & Rotary AC Switch

Homeowner Safe

Open your home meter box cover safely without touching bare busbars and confirm the labeled Solar Supply MCB/RCD breaker and outdoor AC isolator sit solidly ON.

✓ Expected ResultIdentifies tripped breaker or switched-off rotary isolator immediately.
→ If Fault PersistsIf resetting the switchboard breaker immediately trips it back OFF, leave it OFF and call an electrician.
2

Check Neighborhood Power & Wait Synchronization Window

Homeowner Safe

Verify neighborhood power is completely restored and allow 5 minutes after closing breakers for Fronius startup self-checks to finish cleanly.

✓ Expected ResultInverter status turns solid green and begins feeding power automatically.
→ If Fault PersistsSchedule licensed electrician inspection if State 107 stays active with confirmed incoming mains at switchboard.
3

Safely Execute One Exterior Switch Cycle or Book Electrician

Homeowner Safe

Only if the Solar Supply MCB stayed solid ON and house power works normally, turn Solar AC off, bottom DC switch off for 5 minutes until dark, then DC on and AC on—if State 107 stays locked, contact an electrician.

✓ Expected ResultConfirms external switchboard continuity vs AC isolator/terminal interruption.
→ If Fault PersistsNever open wiring boxes; share breaker behavior and LCD voltage readout with installer.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 107? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Switchboard Circuit Breaker Visual Access
  • ✓Fronius Solar.web Portal Access
  • ✓Inverter Serial Number Label

❓ Frequently Asked Questions

Why does my Fronius show State 107 when my kitchen lights are working normally?

The dedicated Solar Supply breaker or AC isolator serving only the inverter likely tripped independently—or on three-phase homes, one single street fuse blew affecting the inverter without knocking out indoor lights.

What if my Solar AC breaker immediately trips back OFF when I push it up?

Do NOT force it back ON! An instant breaker trip indicates an active short circuit or moisture earth fault in AC conduits requiring immediate electrician testing.

Does State 107 hurt my solar panels while production is stopped?

No—solar panels sit safely at open-circuit idle while the inverter waits cleanly for utility AC grid restoration.

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).