Fronius State 107: AC Grid Outside Permissible Limits / No Grid Detected
Affected Models: Fronius Primo, Symo, Eco, Galvo & GEN24 / GEN24 Plus
⚡ Quick Engineering Answer
Fronius • State 107Fronius State 107 signals that the inverter cannot detect a stable utility AC grid while attempting startup synchronization—most commonly caused by a neighborhood power outage, a tripped Solar Supply Main Switch in the meter box, or an external AC isolator left OFF. Check switchboard breakers first before calling a technician.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- AC grid missing or combined grid parameters out of bounds while inverter attempts synchronization.
- Trigger Threshold
- Zero AC utility voltage detected or sustained combined voltage/frequency disturbance during sync check
- Recovery Window
- Auto-clears 60–180s once steady mains AC power is restored
- Subsystem Affected
- AC Main Contactor & Utility Detection Input
- Warranty Outlook
- External breaker trip, utility outage, or loose external AC switch (not hardware failure unless breakers stay ON)
How Fronius State 107 Triggers
Unlike solar off-grid machines, standard Fronius grid-tied systems require a clean incoming utility reference signal to synchronize sine waves safely. Fronius State 107 (AC grid outside permissible limits / No AC Grid detected) logs when AC terminals either read zero voltage completely or register unstable combined voltage/frequency glitches during startup.
This is among the most routine Fronius service calls, frequently resolved cleanly inside the homeowner's electrical distribution board when an RCD/RCBO or dedicated Solar Supply breaker trips quietly during lightning storms or heavy appliance faults—leaving rooftop panels sunlit while no AC feed reaches the inverter.
🔀 Hardware & Series Differences
Often simply indicates AC isolator switch or main switchboard solar MCB tripped OFF.
Verify automated transfer switch (ATS / Backup Switch) status on battery backup installations.
🔍 Observable Symptoms
- •Inverter fan sits idle in bright sunshine displaying State 107 on LCD or Solar.web.
- •AC circuit breaker labeled 'Solar Main Switch' in meter board found flipped OFF.
- •Occurs immediately following local utility blackouts or lightning thunderstorms.
- •Zero watts fed into grid despite strong DC string voltages on diagnostics page.
⚙️ Ranked Root Causes
Lightning surges or damp outdoor AC conduits trip earth-leakage RCDs while keeping house lights on.
Inverter remains safely in anti-islanding lockout until utility power returns.
Gardener, painter, or maintenance worker switched rotary AC isolator off near inverter.
Heat-damaged AC plug inside inverter bottom bay disconnects one phase physically.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightCheck meter box for tripped breakers labeled Solar Supply and confirm rotary AC switch reads ON.
Ensure utility electricity is present inside home outlets and allow startup test timers to finish.
Switch Solar AC off -> DC off -> wait 3 minutes until screen fades -> DC on -> AC on.
Safe External Scope: Do Not Open Covers or Probe Terminals
All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.
🔧 Interactive Step-by-Step Diagnostic Checklist
Check Main Switchboard Solar Breaker & Rotary AC Switch
Open your home meter box cover safely without touching bare busbars and confirm the labeled Solar Supply MCB/RCD breaker and outdoor AC isolator sit solidly ON.
Check Neighborhood Power & Wait Synchronization Window
Verify neighborhood power is completely restored and allow 5 minutes after closing breakers for Fronius startup self-checks to finish cleanly.
Safely Execute One Exterior Switch Cycle or Book Electrician
Only if the Solar Supply MCB stayed solid ON and house power works normally, turn Solar AC off, bottom DC switch off for 5 minutes until dark, then DC on and AC on—if State 107 stays locked, contact an electrician.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing State 107? Copy this structured engineering summary for your installer or OEM RMA ticket.
📋 Homeowner Preparation & Read-Only Access Needed
No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:
- ✓Switchboard Circuit Breaker Visual Access
- ✓Fronius Solar.web Portal Access
- ✓Inverter Serial Number Label
❓ Frequently Asked Questions
Why does my Fronius show State 107 when my kitchen lights are working normally?
The dedicated Solar Supply breaker or AC isolator serving only the inverter likely tripped independently—or on three-phase homes, one single street fuse blew affecting the inverter without knocking out indoor lights.
What if my Solar AC breaker immediately trips back OFF when I push it up?
Do NOT force it back ON! An instant breaker trip indicates an active short circuit or moisture earth fault in AC conduits requiring immediate electrician testing.
Does State 107 hurt my solar panels while production is stopped?
No—solar panels sit safely at open-circuit idle while the inverter waits cleanly for utility AC grid restoration.
Related Fronius Fault Codes
AC grid voltage exceeded upper statutory protection limit, pausing solar feed-in to protect home appliances and grid stability.
AC grid voltage dipped below lower statutory safety threshold, halting export until utility voltage stabilizes.
Utility grid or backup generator AC frequency exceeded upper permitted limit, pausing solar feed-in.
Safety grid relay failed open/close self-test or neutral-to-ground voltage exceeded safety threshold.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).