⚡ Certified Solar & Heat Pump Hardware Diagnostics • Verified Against 2026 Engineering Specs
VoltFaults
State 105Medium✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Fronius State 105: AC Grid Frequency Too High (Overfrequency Trip)

Affected Models: Fronius Primo, Symo, Eco (SnapINverter) & GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Normal Curtailed Cycles) - $220 (Generator Governor / Microgrid Config)
Warranty may cover parts
Diag / Fix Time
15 - 45 mins
AC Grid Frequency & Microgrid

⚡ Quick Engineering Answer

Fronius • State 105

Fronius State 105 means AC mains frequency climbed above your active Country Setup upper ceiling (typically >50.5–52.0 Hz on 50 Hz grids or >60.5 Hz on 60 Hz networks). It recovers automatically when frequency stabilizes, and frequently appears on off-grid backup generators spinning too fast or during deliberate utility microgrid curtailment.

Recovery Behavior:Auto-clears automatically as soon as utility AC or backup generator frequency returns inside Country Setup tolerances.
SCHEMATIC // Fronius State 105 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 105: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Utility grid or backup generator AC frequency exceeded upper permitted limit, pausing solar feed-in.
Trigger Threshold
Utility/generator AC frequency > configured upper Country Setup ceiling (e.g., >51.5–52.0 Hz or >60.5–62.0 Hz)
Recovery Window
Auto-reconnects within 60–300s after AC frequency drops back inside standard band
Subsystem Affected
Grid Frequency PLL Synchronization Stage
Warranty Outlook
Normal grid/generator frequency regulation or deliberate AC-coupled battery charge cutoff

How Fronius State 105 Triggers

Public electrical networks balance supply and demand tightly around nominal 50.00 Hz or 60.00 Hz. When surplus power floods an isolated feeder or diesel backup generator governors run fast under light loads, system frequency climbs upward. Fronius State 105 (AC frequency too high) disconnects solar generation cleanly to uphold anti-islanding regulations and frequency stability.

Before State 105 hits complete disconnection, newer Fronius units operating under active grid codes perform linear power curtailment (State 560). On properties utilizing off-grid GEN24 backup or standalone microgrids (such as Victron AC-coupling or islanded generators), micro-inverters intentionally raise AC frequency up to 51–53 Hz specifically to trigger controlled shutdown of solar production once batteries approach 100% charge.

🔀 Hardware & Series Differences

Grid-Tied SnapINverter & GEN24
AC frequency exceeded regional utility grid code upper boundary

Usually precedes or follows State 560 over-frequency power reduction during grid transients.

GEN24 Microgrid / AC-Coupled Storage Setups
Normal battery-full curtailment signaling (frequency shifting) by off-grid battery inverter

Confirm Microgrid (MG50 / MG60) setup is applied if running on islanded diesel generator or off-grid battery inverter.

🔍 Observable Symptoms

  • •State 105 appears repeatedly when running a home backup generator alongside solar panels.
  • •Coincides with battery banks reaching 100% full charge on AC-coupled off-grid systems.
  • •Logs briefly alongside State 560 during utility switching transients or stormy grid events.
  • •Resumes export automatically once grid power or battery SoC drops slightly.

⚙️ Ranked Root Causes

Intentional frequency shifting by AC-coupled battery inverter when batteries hit 100% chargeHigh

Off-grid battery inverters deliberately shift AC frequency upward to curb excess solar production safely.

Backup diesel/petrol generator spinning slightly fast under light load (>51.5 Hz)High

Mechanical generator governors overspeed cleanly above tight grid-tied limits without load.

Incorrect Country Setup frequency base (50 Hz profile installed on 60 Hz utility)Medium

Regional preset mismatch creates constant out-of-frequency lockout from first power-on.

Rare regional utility transmission disturbance causing brief grid overfrequency spikesLow

Sudden load shedding across local transmission substations causes momentary frequency overshoot.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Battery Charge State & Generator Status

Verify whether off-grid batteries are full or a standby generator is supplying the property.

2CHECK / VERIFY
Read Grid Frequency (Hz) via Solar.web / Display

Inspect active frequency readout (normal ~50.0 Hz or ~60.0 Hz) without opening hardware.

3SEQUENCE STEP
Allow 5 Minutes Automatic Re-Sync

Once frequency normalizes below cutoff threshold, production restarts automatically.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Whether Standby Generator or Off-Grid Battery Is Active

Homeowner Safe

Check whether your property is operating on a backup generator or off-grid battery bank at full 100% SoC—intentional frequency shifting routinely triggers State 105 cleanly.

✓ Expected ResultExplains intermittent shutdowns on sunny battery-full afternoons.
→ If Fault PersistsMonitor AC frequency graphs on Solar.web when on normal utility mains.
2

Verify Regional 50 Hz / 60 Hz Standard in System Info

Homeowner Safe

View your active Country Setup label on the inverter WebUI or LCD menu (view-only) to confirm 50 Hz regions do not accidentally run 60 Hz profiles or vice versa.

✓ Expected ResultIdentifies instant commissioning grid-code mismatches.
→ If Fault PersistsContact your installer to adjust generator governor speed or Microgrid MG50/MG60 profile.
3

Log Frequency Spikes for Generator / Installer Tuning

Homeowner Safe

Download frequency telemetry charts from Solar.web showing peak Hz during generator or microgrid runs so an off-grid technician can fine-tune generator governor RPM or verify MG50/MG60 droop parameters.

✓ Expected ResultSmooths microgrid curtailment without hard State 105 disconnects.
→ If Fault PersistsNotify utility provider if State 105 persists on grid-tied mains.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 105? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Fronius Solar.web Event Telemetry
  • ✓Inverter LCD / WebUI Display Access
  • ✓Backup Generator Operating Manual (If Off-Grid)

❓ Frequently Asked Questions

Why does Fronius State 105 happen every day around noon on my off-grid battery system?

That is intentional frequency shifting! Once your off-grid battery hits 100% charge, the battery inverter bumps AC frequency above 51.5 Hz so Fronius pauses safely.

Does State 105 indicate damaged solar inverter hardware?

No—it shows the inverter's frequency protection sensors are correctly preventing over-speed energy injection onto unstable utility lines or generators.

Can Fronius run safely on a portable backup generator?

Standard grid profiles frequently reject unstable portable generator Hz; installers must match compatible inverters and apply Microgrid MG50/MG60 settings per off-grid specifications.

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians