Fronius Error Codes & Fix Guides
Austrian engineered premium solar string inverters (Symo, Primo, Galvo, and Gen24 Plus series) renowned for SnapINverter modular architecture. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Fronius Hardware Signal Topology
Fronius Diagnostic Profile (22 Codes)
Fronius State 102: AC Grid Voltage Too High (Overvoltage Trip)
AC grid voltage exceeded upper statutory protection limit, pausing solar feed-in to protect home appliances and grid stability.
Fronius State 103: AC Grid Voltage Too Low (Undervoltage Trip)
AC grid voltage dipped below lower statutory safety threshold, halting export until utility voltage stabilizes.
Fronius State 105: AC Grid Frequency Too High (Overfrequency Trip)
Utility grid or backup generator AC frequency exceeded upper permitted limit, pausing solar feed-in.
Fronius State 107: AC Grid Outside Permissible Limits / No Grid Detected
AC grid missing or combined grid parameters out of bounds while inverter attempts synchronization.
Fronius State 240: DC Arc Detected (AFCI Safety Shutdown)
AFCI safety hardware detected dangerous DC arcing on solar string wiring and locked out production.
Fronius State 301: AC Overcurrent Transient (Brief Feed-In Pause)
Short-term overcurrent transient on the AC side caused a temporary protective pause and automatic restart.
Fronius State 303: DC-AC Power Stage Set Heatsink Over-Temperature
DC-AC power stage heatsink overheated due to restricted airflow, stalled cooling fan, or extreme sun exposure.
Fronius State 304: Internal / DC-DC Board Over-Temperature
Internal cabinet or DC-DC converter board temperature rose above safe threshold due to trapped heat or fan stoppage.
Fronius State 307: DC Low Input Voltage (PV Array Under Start Threshold)
Solar DC string voltage fell below inverter startup minimum—normal at dawn/dusk or signal of OFF DC switch in midday.
Fronius State 401: No Communication with Power Stage Set
Internal digital communication failed between control brain board and power stage set.
Fronius State 443: Intermediate Circuit (DC-Link) Voltage Fault
Internal DC-link intermediate circuit bus voltage dropped too low or became unbalanced between positive and negative legs.
Fronius State 457: Grid Relay Sticking / High Neutral-to-Ground Voltage
Safety grid relay failed open/close self-test or neutral-to-ground voltage exceeded safety threshold.
Fronius State 474: RCMU Sensor Defective (Residual Current Unit Fault)
Internal Residual Current Monitoring Unit (RCMU) safety sensor failed calibration self-test or malfunctioned.
Fronius State 475: Solar Panel Ground Fault (Low Insulation Resistance)
Insulation resistance between DC solar strings and earth dropped below safety floor due to moisture ingress or cable damage.
Fronius State 509: No Solar Feed-In for 24 Hours (Production Pause Alert)
Informational notice stating zero energy has been fed into the AC grid for 24 consecutive hours.
Fronius State 516: Storage Unit Communication Fault / Power Stage Error Limit
Communication error with connected battery storage unit / filter, or SnapINverter daily power-stage logging warning.
Fronius State 517: Power Limitation / Thermal Derating Active
Inverter proactively lowered maximum AC wattage output to prevent overheating under hot conditions or restricted cooling.
Fronius State 558: Functional Incompatibility (Internal PC Board / Firmware Mismatch)
One or more internal inverter PC boards are running incompatible firmware revisions or mismatched hardware versions.
Fronius State 560: Power Reduction Due to Over-Frequency (Grid Support P(f))
Inverter actively curtailed output power to help stabilize grid frequency above standard over-frequency start point.
Fronius State 567: Grid-Voltage Dependent Power Reduction (Volt-Watt Mode)
Inverter scaled back export power under Volt-Watt rules because local grid voltage rose high.
Fronius State 705: Inverter Number Conflict on Solar.Net Ring
Multiple inverters daisy-chained onto a Fronius Solar.Net loop share duplicate device numbers, colliding on monitoring telemetry.
Fronius State 731: USB Flash Drive Initialization / Read Error
USB flash drive plugged into inverter failed initialization during logging or local firmware update.