Fronius State 102: AC Grid Voltage Too High (Overvoltage Trip)

Affected Models: Fronius Primo, Symo, Eco, Galvo (SnapINverter) & Primo/Symo GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Utility Review) - $280 (AC Cable Upgrade / Audit)
Warranty may cover parts
Diag / Fix Time
15 - 60 mins
AC Grid Voltage Protection

⚡ Quick Engineering Answer

Fronius • State 102

Fronius State 102 indicates that the AC utility grid voltage measured at the inverter output has exceeded the maximum statutory limit defined in your Country Setup (often >253V–264V single-phase). It clears automatically when neighborhood grid voltage drops, though recurring midday trips typically signal street transformer tap issues or high AC cable voltage rise.

Recovery Behavior:Auto-clears automatically once utility AC grid voltage settles back below the upper Country Setup limit and synchronization timers elapse.
SCHEMATIC // Fronius State 102 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 102: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
AC grid voltage exceeded upper statutory protection limit, pausing solar feed-in to protect home appliances and grid stability.
Trigger Threshold
AC grid voltage > configured Country Setup upper ceiling (typically +10% to +15% nominal, e.g., >253V–264V)
Recovery Window
Auto-reconnects 60–300s after AC voltage drops back inside permissible range
Subsystem Affected
AC Grid Monitoring & Anti-Islanding Relays
Warranty Outlook
External utility voltage or AC cable voltage-rise issue (not a hardware defect)

How Fronius State 102 Triggers

As roof solar penetration surges during sunny midday hours, back-feeding power onto local neighborhood distribution lines causes street transformer voltages to float upward. Fronius State 102 (AC voltage too high) activates whenever grid voltage measured at the inverter AC terminals climbs past the configured grid-code trip ceiling (e.g., >253V–264V RMS in 230V regions, or >264V across 240V split-phase markets).

Both SnapINverter (Primo, Symo, Galvo) and GEN24 / GEN24 Plus units treat State 102 as a safety grid-monitoring pause rather than an internal defect: internal grid relays stay open until utility voltage returns safely inside tolerance for the mandated reconnection window (typically 60–300 seconds). Note that long, undersized AC wiring runs between the inverter and main switchboard artificially inflate inverter-terminal voltage ('voltage rise') even when street supply sits within normal limits.

🔀 Hardware & Series Differences

Fronius SnapINverter (Primo / Symo / Eco)
State 102 displayed on front LCD during AC grid overvoltage cutoff

Compare Solar.web L1/L2/L3 AC voltage graphs during peak noon generation to identify which phase trips.

Fronius GEN24 / GEN24 Plus
Event 102 logged in Solar.web and local WebUI when grid RMS voltage exceeds regional grid profile

Hybrid GEN24 units can continue PV-to-battery DC charging even while AC export relays remain paused.

🔍 Observable Symptoms

  • •State 102 appears reliably between 10:30 AM and 2:30 PM on clear, sunny, mild days when neighborhood consumption is low.
  • •Inverter orange/red status LED flashes and AC output drops to 0W before restarting 5–10 minutes later.
  • •Often preceded by State 567 (Grid-Voltage Dependent Power Reduction / Volt-Watt derating) right before complete cutoff.
  • •Solar production runs steadily on overcast days or early mornings without errors.

⚙️ Ranked Root Causes

High neighborhood utility grid voltage during peak solar feed-in hoursHigh

Local utility substation transformers sit above nominal 230V/240V when surrounding rooftop arrays export simultaneously.

Voltage rise across undersized or overly long AC feeder cable to main switchboardHigh

Exporting high current over thin AC wire adds 5V–10V specifically at inverter terminals.

Incorrect Country Setup grid code selected during commissioningMedium

Tighter European/Australian profiles trip sooner than regional utility operating envelopes.

Loose or corroded AC breaker lug creating resistive heating and voltage spikesLow

High-resistance termination adds voltage drop/rise distortion during heavy export.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Real-Time AC Grid Voltage in Solar.web or Display

Log peak AC grid voltage shown right before State 102 triggered (e.g., 258V–265V).

2DISCHARGE / WAIT
Wait 5 Minutes for Grid Stabilization

Avoid forcing manual reboots; relays re-close automatically as soon as utility voltage drops.

3CHECK / VERIFY
Acknowledge Notice & Monitor Midday Graphs

Press Enter on SnapINverter display or inspect Solar.web Daily Power Curve for saw-tooth dropouts.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Review Peak AC Voltage Curves in Fronius Solar.web

Homeowner Safe

Open Fronius Solar.web (or press display buttons safely on SnapINverter) to record exact AC voltage values on L1/L2/L3 during peak midday State 102 dropouts.

✓ Expected ResultConfirms whether voltage consistently crosses 253V–260V during bright sun.
→ If Fault PersistsExport daily AC voltage screenshots to support a utility voltage complaint.
2

Observe Companion State 567 & Appliance Timing

Homeowner Safe

Notice whether State 567 (Volt-Watt derating) logs just before State 102, and shift heavy flexible appliances (hot water heater, pool pump, EV) toward midday hours to absorb surplus export safely.

✓ Expected ResultDrops local service-main voltage slightly and often eliminates nuisance shutdowns.
→ If Fault PersistsMonitor whether State 102 still strikes even when zero clouds or appliances run.
3

Collect Timestamped Voltage Logs & Contact Utility / Installer

Homeowner Safe

Save 3–5 days of Solar.web AC voltage screenshots and notify your electricity distributor or solar installer so a licensed electrician can audit switchboard voltage drop and approved Q(U) reactive power settings.

✓ Expected ResultEstablishes clear evidence for free street transformer tap lowering or AC cable upsizing.
→ If Fault PersistsAsk your installer to review Volt-Var grid response compliance with your power utility.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 102? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Fronius Solar.web Mobile App
  • ✓Fronius SnapINverter LCD / WebUI Display
  • ✓Utility Meter Reference Number

❓ Frequently Asked Questions

Does Fronius State 102 mean my inverter is broken?

No—99% of State 102 events indicate your inverter is functioning properly as a safety guard because neighborhood utility voltage climbed above local grid limits.

Why does State 102 happen mostly around noon on sunny spring or winter days?

Cooler sunny weather produces peak solar generation across neighborhood roofs while household A/C usage is low, pushing local distribution voltage above 253V–260V.

Can my installer raise the overvoltage limit inside Fronius settings?

Only within strict utility distributor rules; however, technicians can enable Volt-Var reactive power or shorten/thicken AC feeder cables to stop nuisance voltage rise.

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).