State 567Low✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Fronius State 567: Grid-Voltage Dependent Power Reduction (Volt-Watt Mode)

Affected Models: Fronius Primo, Symo, Eco & GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Shift Loads) - $280 (AC Cable Upgrade)
Warranty may cover parts
Diag / Fix Time
15 - 60 mins
Volt-Watt Grid Support Derating

⚡ Quick Engineering Answer

Fronius • State 567

Fronius State 567 signals Grid-Voltage Dependent Power Reduction (Volt-Watt Mode)—NOT an emergency backup overload! When afternoon solar exports push street AC voltage high (commonly above ~250V–255V in Australia/Europe), Fronius smoothly reduces export power to prevent complete overvoltage cutoffs (State 102). Review midday AC voltage curves and shift heavy loads to solar noon.

Recovery Behavior:Recovers full output automatically as soon as midday neighborhood grid voltage dips back beneath Volt-Watt derating ceiling (typically ~250V–255V).
SCHEMATIC // Fronius State 567 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 567: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter scaled back export power under Volt-Watt rules because local grid voltage rose high.
Trigger Threshold
AC voltage enters Volt-Watt droop band (~250V–255V on 230V/240V lines)
Recovery Window
Full kW output resumes automatically as street AC voltage dips back down
Subsystem Affected
Volt-Watt Grid Voltage Management
Warranty Outlook
Mandatory grid compliance response; external utility/AC wire sizing issue

How Fronius State 567 Triggers

Modern smart grid rules require Volt-Watt Power Quality Response so dense solar suburbs do not spike street voltage to dangerous levels. Instead of switching off suddenly at upper limits (State 102), Fronius State 567 (Grid-Voltage Dependent Power Reduction) trims export kW gently once terminal voltage climbs past regional start points (commonly >250V–255V).

Practical Tip: Running a pool pump, electric vehicle charger, or water heater during sunny midday consumes surplus power locally, lowering household voltage and erasing State 567 losses immediately. Chronic daily clipping typically reflects high street transformer taps or thin AC cables.

🔀 Hardware & Series Differences

Fronius SnapINverter & GEN24 (AS4777 / VDE / UL1741)
Active Volt-Watt power curtailment guarding utility voltage ceilings

Compare L1/L2/L3 AC voltage graphs during clear 11 AM – 2 PM windows.

GEN24 Plus Hybrid Storage Installations
Grid export throttles cleanly while solar surplus redirects into DC battery charging

Delaying battery charging until midday soaks solar peaks without lifting street voltage.

🔍 Observable Symptoms

  • •Solar.web alerts log State 567 daily between 11 AM and 2:30 PM on sunny days.
  • •Afternoon output plateaus flat without dropping completely to zero (State 102).
  • •AC voltage chart stays around ~252V–258V during curtailed midday windows.
  • •Curtailment disappears briefly when A/C, water heaters, or EV chargers turn on.

⚙️ Ranked Root Causes

High neighborhood solar export lifting street distribution voltage above 250VHigh

Utility transformers tuned high at 245V idle get pushed over 253V across sunny suburbs.

Thin or lengthy AC cable between inverter and main meter creating voltage riseHigh

Small feeder wires lose 6V+ between switchboard and inverter terminals under full export.

Early morning battery charging filling storage by 10 AM and dumping full noon PVMedium

Missed opportunity to charge battery at peak voltage noon hours.

Regional Volt-Watt grid code working as legally requiredLow

Prevents harsh repeated total overvoltage disconnects.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Verify Midday AC Voltage Curve in Solar.web

Confirm whether phase AC voltages sit near 250V–258V precisely during flat output plateaus.

2SEQUENCE STEP
Shift High Home Loads & Battery Charge Window Toward Solar Noon

Run hot-water timers, pool pumps, or delay battery charging until 11 AM–2 PM to soak voltage safely.

3SEQUENCE STEP
Contact Utility / Electrician If Nighttime Voltage Exceeds 245V

Share Solar.web voltage screenshots with your power distributor to request transformer tap lowering.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Midday AC Voltage Readings & Test Heavy Load Shifting

Homeowner Safe

Review AC voltage charts inside Solar.web between 11 AM and 2 PM safely, and schedule hot-water elements, pool filtration, or EV charging inside midday peaks to lower household grid voltage naturally.

✓ Expected ResultConverts curtailed excess power straight into free household usage while erasing 567 losses.
→ If Fault PersistsCheck battery time-of-use charge delays so home storage absorbs noon solar peaks.
2

Collect Voltage Proof If Night/Idle Voltage Already Runs High

Homeowner Safe

Check midnight or dawn grid voltage on Solar.web—if street voltage already sits around 245V+ even at midnight with zero solar exporting, submit a formal High Voltage notification to your utility provider.

✓ Expected ResultUtility line crews lower street transformer taps cleanly at no charge to homeowners.
→ If Fault PersistsAsk a licensed solar electrician to check switchboard-to-inverter AC wire sizing.
3

Request Electrician Volt-Var & AC Feeder Check If Street Voltage Is Normal

Homeowner Safe

If midnight street grid voltage sits cleanly around 230V–238V yet inverter terminals spike past 254V at noon, hire a licensed electrician to verify switchboard AC cable gauge and utility-approved Volt-Var (Q(U)) mode.

✓ Expected ResultEliminates local AC cable voltage rise cleanly while boosting net daily kWh yield.
→ If Fault PersistsProvide full exported voltage charts to utility network engineering team.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 567? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Fronius Solar.web AC Voltage History Logs
  • ✓Appliance / Pool Timer Scheduling
  • ✓GEN24 / Smart Meter Monitoring View

❓ Frequently Asked Questions

Is Fronius State 567 caused by an overload on my GEN24 emergency backup output?

NO! Officially State 567 stands for Grid-Voltage Dependent Power Reduction (Volt-Watt compliance mode)—not emergency backup overload. It means utility street voltage climbed high (~250V+) so Fronius throttled export to comply with grid codes.

Should I get my installer to disable State 567 Volt-Watt mode?

No—disabling mandated Volt-Watt protection violates utility interconnection contracts and actually triggers harsh complete shutdowns (State 102) costing you even more total energy!

How can I save wasted energy lost during daily State 567 throttling?

Schedule heavy home loads (hot water, EV, pool pump, battery noon-charging windows) between 11 AM and 2 PM—consuming solar before it raises AC street voltage!

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians