Fronius State 560: Power Reduction Due to Over-Frequency (Grid Support P(f))

Affected Models: Fronius Primo, Symo, Eco & GEN24 Plus

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Normal Function) - $180 (MG50 Off-Grid Tune)
Warranty may cover parts
Diag / Fix Time
5 - 30 mins
Grid Compliance & Frequency Derating

⚡ Quick Engineering Answer

Fronius • State 560

Fronius State 560 means active Power Reduction Due to Over-Frequency (P(f) grid support mode)—NOT a SolarNet loop defect! When neighborhood grid or backup microgrid AC frequency creeps past regional standards (commonly >50.2 Hz or >60.5 Hz), Fronius smoothly ramps wattage down rather than tripping abruptly offline. It self-clears automatically once AC frequency normalizes.

Recovery Behavior:Auto-clears smoothly as utility or microgrid AC frequency returns below the grid-code P(f) curtailment knee (e.g., <50.2 Hz).
SCHEMATIC // Fronius State 560 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
Fronius State 560: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter actively curtailed output power to help stabilize grid frequency above standard over-frequency start point.
Trigger Threshold
Utility or microgrid AC frequency enters regional P(f) droop band (typically 50.2–51.5 Hz or 60.2–61.5 Hz)
Recovery Window
Auto-clears immediately once frequency settles safely back inside nominal band (50.0 / 60.0 Hz)
Subsystem Affected
Active Power Regulation P(f) & PLL Frequency Loop
Warranty Outlook
100% normal compliant behavior (0% inverter fault unless Country Setup wrong)

How Fronius State 560 Triggers

Under modern grid codes (VDE-AR-N 4105, EN50549, AS4777, IEEE 1547-2018), solar inverters help utilities stabilize electrical grid frequency smoothly instead of tripping offline suddenly. Whenever surplus solar or load drops push local utility frequency gently past 50.2 Hz (or 60.5 Hz), Fronius State 560 (Derating caused by over-frequency) proportionally reduces AC output power (P(f) droop curve).

Microgrid / Off-Grid Battery Bonus: On homes combining Fronius PV inverters AC-coupled onto Victron/off-grid battery inverters or diesel backup generators, State 560 is critical and completely normal! Once off-grid batteries approach 95%–100% full charge, the battery inverter bumps AC frequency deliberately up to 50.3–51.5 Hz so Fronius throttles smoothly with State 560—matching PV generation exactly to house load before jumping to full cutoff (State 105).

🔀 Hardware & Series Differences

Grid-Tied SnapINverter & GEN24
Active grid-compliance frequency-watt (P(f)) power throttling above utility start point (e.g., >50.2 Hz)

Compare cleanly with State 567 (over-voltage throttling) and State 105 (complete over-frequency trip).

AC-Coupled Off-Grid / Victron Microgrid
Intentional proportional curtailment matching battery absorption ceiling

Requires MG50/MG60 microgrid frequency-response setup for buttery-smooth battery charge control without frequent full disconnects.

🔍 Observable Symptoms

  • •State 560 logs repeatedly in Solar.web notifications on off-grid battery systems during sunny afternoon fullness.
  • •Output power drops softly toward household consumption wattage right after batteries reach ~98% SoC.
  • •Pressing Enter dismisses notice temporarily without affecting active generation.
  • •Occasional State 560 flashes on utility grids during national emergency frequency-stabilization events.

⚙️ Ranked Root Causes

Intentional frequency shifting by AC-coupled off-grid battery inverter as batteries hit full SoCHigh

Victron MultiPlus/Quattro and off-grid inverters bump Hz slightly from 50.2 to 51.0 Hz to signal smooth curtailment.

Backup diesel/gas generator running slightly above nominal 50.2 Hz / 60.2 Hz under light loadHigh

Slightly fast generator mechanical speed activates smooth P(f) curtailment immediately.

Regional utility over-frequency stabilization event on grid-tied networksMedium

Local grid over-generation triggers coordinated droop curtailment across connected smart inverters.

Wrong Country Setup selected (e.g., tighter 50.1 Hz threshold profile vs national utility code)Low

Overly strict country droop starts throttling under minor everyday grid swings.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Active AC Frequency (Hz) & Battery Charge State

View real-time Hz in Solar.web/LCD and verify whether batteries hit 98%–100% on off-grid/AC-coupled sites.

2SEQUENCE STEP
Understand Normal Grid-Code Compliance—No Hardware Action Needed

Output recovers automatically when battery draws load or utility Hz settles back toward 50.0 / 60.0 Hz.

3CHECK / VERIFY
Verify Microgrid MG50/MG60 Profile Only If Running Generator/Off-Grid

Ask your off-grid installer to disable redundant State 560 alert emails if cycling daily as intended.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Utility Grid vs Off-Grid Battery Curtailment Context

Homeowner Safe

Check whether batteries sit nearly full on an AC-coupled off-grid home or if standby generators run when State 560 logs—if so, State 560 confirms smooth solar power throttling is working perfectly.

✓ Expected ResultConfirms zero repair is required for healthy microgrid curtailment.
→ If Fault PersistsInspect Solar.web Frequency graph if State 560 occurs on normal utility power with empty loads.
2

Compare Active Country Profile & Grid Frequency Telemetry

Homeowner Safe

View System Info > Country Setup safely on LCD/WebUI to verify your correct country code is displayed and check logged Hz spikes right when power dropped.

✓ Expected ResultIdentifies accidental foreign grid code setups or fast-running standby generators.
→ If Fault PersistsHave an installer review P(f) curve settings or generator speed governor.
3

Request Off-Grid / MG50 Fine-Tuning If Curtailment Cycles Harshly

Homeowner Safe

If State 560 cycles harshly on off-grid battery setups or backup generators, share Solar.web frequency graphs with your installer so they can apply Fronius MG50/MG60 tuning or calibrate generator speed.

✓ Expected ResultEnsures silent seamless solar tapering and lets you mute redundant informational email alerts.
→ If Fault PersistsMonitor utility stability if seen frequently while strictly grid-connected.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing State 560? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Fronius Solar.web Service Message Log
  • ✓Inverter System Info Menu (View-Only)
  • ✓Off-Grid Battery / Generator User Guide

❓ Frequently Asked Questions

Does Fronius State 560 mean my SolarNet data cable broke?

NO! That is a common internet myth. Officially across Fronius SnapINverter and GEN24 manuals, State 560 specifically indicates over-frequency active power reduction (P(f)).

Why do I get State 560 every sunny afternoon with my Victron battery system?

Your battery inverter purposefully shifts grid frequency up slightly (~50.3–51.0 Hz) once batteries approach 100% so your Fronius throttles smoothly without overcharging cells—100% normal!

Will clearing State 560 give me more free daytime power on grid-tie?

No—once local neighborhood grid frequency settles safely back down to 50.0/60.0 Hz, full solar output restores automatically on its own.

Related Fronius Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians