⚡ Quick Engineering Answer

SMA Sunny Boy • Error 6801

SMA Event 6801 (Self-diagnosis: Input A defective) means the inverter's morning hardware self-test caught a defective DC boost converter, current sensor, or diode on String Input A. While testing a string swap onto Input B helps installers confirm array health, hardware Event 6801 requires certified SMA repair or unit RMA replacement.

Recovery Behavior:Locks MPPT Input A or whole inverter off safely once startup boost/current-sensor diagnostics fail; normally requires SMA warranty inverter replacement.
SCHEMATIC // SMA Sunny Boy Error 6801 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
SMA Sunny Boy Error 6801: PV Array, AFCI & DC Boost Stage System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PV Array, AFCI & DC Boost Stage
Signal / Power Path
Roof Strings / MC4 / Optimizers -> DC Isolator & MPPT
Safety Access Line
Sealed Chassis — MPPT Input A Boost MOSFET/IGBT, Freewheeling Diode & Current Sensor

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Startup self-diagnostics detected a hardware defect on PV String Input A boost or current-sensing stage.
Trigger Threshold
Input A current sensor offset, boost test voltage, or switch continuity fails startup check
Recovery Window
Hardware lockout—requires certified SMA warranty swap or power-stage repair
Subsystem Affected
MPPT Input A Boost MOSFET/IGBT, Freewheeling Diode & Current Sensor
Warranty Outlook
High—internal DC power-stage defects fall squarely under SMA 5–10 year hardware warranty

How SMA Sunny Boy Error 6801 Triggers

On multi-tracker SMA Sunny Boy and Sunny Tripower inverters, Input A and Input B each drive dedicated DC-DC boost MOSFET/IGBT stages and Hall-effect current sensors before feeding the shared DC bus. Every sunrise, startup software checks zero-current offsets, diode integrity, and boost switching response.

Hardware Stage Failure vs. String Test: If internal boost semiconductors short, an input Hall current sensor drifts far from zero at rest, or gate drivers fail, Event 6801 permanently disconnects Input A (or halts the inverter) to avoid board burns. Event 6801 mirrors Event 6901 cleanly for Input B and normally ends in SMA RMA exchange.

🔀 Hardware & Series Differences

SMA Sunny Boy Single-Phase Dual-MPPT
Event 6801 (Self-diagnosis: Input A defective — DC boost A switch or current Hall sensor failed)

Compare telemetry against Event 6901 (Input B defective); never run without technician check.

SMA Sunny Tripower Three-Phase
Tracker A boost chopper failure or reverse-current sensor defect

Occasionally triggered if parallel strings on Input A exceeded rated short-circuit Isc limits.

🔍 Observable Symptoms

  • •Red LED illuminates cleanly alongside Self-diagnosis: Input A defective (6801) in Event Logbook.
  • •Zero watts generated from String A (or entire inverter shuts off safely at sunrise).
  • •Occasionally appears right alongside DC boost overcurrent alarms after heavy summer heat.

⚙️ Ranked Root Causes

Shorted or open DC boost switching semiconductor / freewheeling diode inside Input A stageHigh

Boost stage aging or lightning transients destroy silicon switches feeding Input A.

Drifted Hall-effect DC current sensor reporting false current at zero load on Input AHigh

Zero-offset checks fail every morning prior to closing DC boost path.

Over-current array design paralleling too many strings directly onto Input AMedium

Exceeding max rated Idc max thermally stresses Input A components faster than Input B.

Reverse DC polarity strike bypassing protection diode (low)Low

Miswired MC4 plugs force fault currents through Input A shunt components.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Switch Solar AC Breaker OFF

Isolate utility AC at the distribution switchboard safely.

2DC / BATT OFF
Rotate Integrated DC Load-Break Switch to 0 (OFF)

Wait 10 minutes until capacitors bleed dry and status LEDs go dead.

3RESTORE & BOOT
Test One Clean Restart; Contact Installer If 6801 Returns

Restore DC then AC once; persistent Event 6801 confirms hardware failure needing RMA.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Run One Clean 10-Minute AC/DC Power Cycle

Homeowner Safe

Isolate AC breaker then turn the black/red DC load-break switch to 0 for 10 full minutes, then power up cleanly once to verify.

✓ Expected ResultEliminates any rare transient offset error caused by sudden twilight voltage swings.
→ If Fault PersistsIf Event 6801 repeats immediately, stop resetting and photograph the Event Logbook details.
2

Note Input A Voltage & Array Layout Details

Homeowner Safe

Look at live WebUI telemetry (if accessible externally) to see whether DC Voltage A reads strangely compared to DC Voltage B.

✓ Expected ResultGives SMA installer valuable evidence separating internal fault from roof strings.
→ If Fault PersistsSubmit serial number and Event 6801 screenshot to your SMA certified technician.
3

Verify String A Open-Circuit Voltage, Polarity & Isc Specs

Licensed Technician

Isolate AC/DC safely, wait 5+ minutes per manual, disconnect Input A DC strings, and measure Voc, polarity, and short-circuit limits against nameplate max.

✓ Expected ResultProves external PV wiring and string current fall strictly inside SMA specs before testing hardware.
→ If Fault PersistsTest clean inverter startup with Input A physically unplugged (open) to confirm Event 6801 originates strictly inside chassis.
4

Process SMA Factory RMA Replacement

Licensed Technician

Upload isolated string test measurements, Vpv/Ipv telemetry, and Event 6801 logbook exports to SMA Online Service Center for unit exchange.

✓ Expected ResultSMA supplies verified replacement inverter because DC boost power stages require factory rework.
→ If Fault PersistsInspect MC4 crimps and string currents before landing strings onto the replacement inverter.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 6801? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •1000V CAT III Multimeter
  • •DC Clamp Ammeter
  • •Sunclix / MC4 Disconnect Tool
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with SMA Sunny Boy Error 6801

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Can my installer move Solar String A over to Input B temporarily?

Only a licensed technician should verify Input B's maximum current/voltage rating (Idc max) before temporarily testing single-tracker operation; if the whole inverter locks on Event 6801, factory RMA replacement is mandatory.

How is Event 6801 different from Event 6901?

They represent identical DC boost/sensor self-test faults on different MPPT channels: Event 6801 flags Input A, whereas Event 6901 flags Input B.

Is SMA Event 6801 covered by factory warranty?

Yes, assuming rooftop string Voc and parallel string currents didn't exceed nameplate limits, DC input-stage hardware failures are covered under SMA's factory warranty.

Related SMA Sunny Boy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).