SMA Event 6801: Self-Diagnosis Input A Defective (DC Stage)
Affected Models: SMA Sunny Boy (SB 3.0–6.0 / -US) & Sunny Tripower (STP 5.0–25TL)
⚡ Quick Engineering Answer
SMA Sunny Boy • Error 6801SMA Event 6801 (Self-diagnosis: Input A defective) means the inverter's morning hardware self-test caught a defective DC boost converter, current sensor, or diode on String Input A. While testing a string swap onto Input B helps installers confirm array health, hardware Event 6801 requires certified SMA repair or unit RMA replacement.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- Startup self-diagnostics detected a hardware defect on PV String Input A boost or current-sensing stage.
- Trigger Threshold
- Input A current sensor offset, boost test voltage, or switch continuity fails startup check
- Recovery Window
- Hardware lockout—requires certified SMA warranty swap or power-stage repair
- Subsystem Affected
- MPPT Input A Boost MOSFET/IGBT, Freewheeling Diode & Current Sensor
- Warranty Outlook
- High—internal DC power-stage defects fall squarely under SMA 5–10 year hardware warranty
How SMA Sunny Boy Error 6801 Triggers
On multi-tracker SMA Sunny Boy and Sunny Tripower inverters, Input A and Input B each drive dedicated DC-DC boost MOSFET/IGBT stages and Hall-effect current sensors before feeding the shared DC bus. Every sunrise, startup software checks zero-current offsets, diode integrity, and boost switching response.
Hardware Stage Failure vs. String Test: If internal boost semiconductors short, an input Hall current sensor drifts far from zero at rest, or gate drivers fail, Event 6801 permanently disconnects Input A (or halts the inverter) to avoid board burns. Event 6801 mirrors Event 6901 cleanly for Input B and normally ends in SMA RMA exchange.
🔀 Hardware & Series Differences
Self-diagnosis: Input A defective — DC boost A switch or current Hall sensor failed)Compare telemetry against Event 6901 (Input B defective); never run without technician check.
Occasionally triggered if parallel strings on Input A exceeded rated short-circuit Isc limits.
🔍 Observable Symptoms
- •Red LED illuminates cleanly alongside
Self-diagnosis: Input A defective (6801)in Event Logbook. - •Zero watts generated from String A (or entire inverter shuts off safely at sunrise).
- •Occasionally appears right alongside DC boost overcurrent alarms after heavy summer heat.
⚙️ Ranked Root Causes
Boost stage aging or lightning transients destroy silicon switches feeding Input A.
Zero-offset checks fail every morning prior to closing DC boost path.
Exceeding max rated Idc max thermally stresses Input A components faster than Input B.
Miswired MC4 plugs force fault currents through Input A shunt components.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightIsolate utility AC at the distribution switchboard safely.
0 (OFF)Wait 10 minutes until capacitors bleed dry and status LEDs go dead.
Restore DC then AC once; persistent Event 6801 confirms hardware failure needing RMA.
High-Voltage / Refrigerant Safety Boundary: Pro Service Split
Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.
🔧 Interactive Step-by-Step Diagnostic Checklist
Run One Clean 10-Minute AC/DC Power Cycle
Isolate AC breaker then turn the black/red DC load-break switch to 0 for 10 full minutes, then power up cleanly once to verify.
Note Input A Voltage & Array Layout Details
Look at live WebUI telemetry (if accessible externally) to see whether DC Voltage A reads strangely compared to DC Voltage B.
Verify String A Open-Circuit Voltage, Polarity & Isc Specs
Isolate AC/DC safely, wait 5+ minutes per manual, disconnect Input A DC strings, and measure Voc, polarity, and short-circuit limits against nameplate max.
open) to confirm Event 6801 originates strictly inside chassis.Process SMA Factory RMA Replacement
Upload isolated string test measurements, Vpv/Ipv telemetry, and Event 6801 logbook exports to SMA Online Service Center for unit exchange.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing Error 6801? Copy this structured engineering summary for your installer or OEM RMA ticket.
🧰 Field Reference: What Your Technician Will Inspect
For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:
- •1000V CAT III Multimeter
- •DC Clamp Ammeter
- •Sunclix / MC4 Disconnect Tool
Don't Risk High-Voltage Shock with SMA Sunny Boy Error 6801
This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:
❓ Frequently Asked Questions
Can my installer move Solar String A over to Input B temporarily?
Only a licensed technician should verify Input B's maximum current/voltage rating (Idc max) before temporarily testing single-tracker operation; if the whole inverter locks on Event 6801, factory RMA replacement is mandatory.
How is Event 6801 different from Event 6901?
They represent identical DC boost/sensor self-test faults on different MPPT channels: Event 6801 flags Input A, whereas Event 6901 flags Input B.
Is SMA Event 6801 covered by factory warranty?
Yes, assuming rooftop string Voc and parallel string currents didn't exceed nameplate limits, DC input-stage hardware failures are covered under SMA's factory warranty.
Related SMA Sunny Boy Fault Codes
Startup self-diagnosis detected an internal hardware defect on PV String Input B boost converter or current sensor.
Core power-stage hardware failed morning internal self-diagnosis, locking inverter synchronization safely offline.
Measured DC string insulation resistance (Riso) dropped below safe safety margin before closing onto utility lines.
Elevated capacitive earth-leakage current exceeded smooth steady thresholds during humid/rainy PV operation.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).