SMA Sunny Boy Error Codes & Fix Guides
German-engineered high-reliability residential and commercial string inverters. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
SMA Sunny Boy Hardware Signal Topology
SMA Sunny Boy Diagnostic Profile (24 Codes)
SMA Event 101: Grid Fault — High Grid Voltage / Line-Neutral Peak
Instantaneous AC phase voltage exceeded regional grid-code upper threshold, disconnecting feed-in safely.
SMA Event 102: Grid Fault — Upper Grid Voltage / Impedance Limit
Secondary upper AC grid threshold or rapid utility impedance shift tripped grid-protection disconnect.
SMA Event 202: Grid Fault — Low Grid Voltage or AC Disconnected
AC grid voltage dropped beneath regional lower limit or vanished completely due to open AC breaker or utility outage.
SMA Event 301: 10-Minute Rolling Mean Grid Voltage Exceeded
Ten-minute moving average utility grid voltage exceeded 110% regional statutory limit (~253V), triggering soft disconnection.
SMA Event 3501: Insulation Failure (PV Array Earth Ground Fault)
Measured DC string insulation resistance (`Riso`) dropped below safe safety margin before closing onto utility lines.
SMA Event 3601: High Discharge / Capacitive Leakage Current
Elevated capacitive earth-leakage current exceeded smooth steady thresholds during humid/rainy PV operation.
SMA Event 3701: Residual Current Too High (RCMU Fault Step)
Residual Current Monitoring Unit detected an acute earth-leakage step surge (`>=30 mA`) during live solar operation.
SMA Event 3801: DC Overcurrent Protection (Input A / B Surge)
PV string current exceeded maximum safe MPPT input rating, forcing boost stage protection cutoff.
SMA Event 3901: Waiting for DC Start Conditions (Low Solar / ESS Off)
Informational status indicating rooftop PV DC voltage or available solar power sits below inverter startup wake threshold.
SMA Event 6400: Self-Diagnosis — Internal Device Disturbance
Internal firmware self-diagnostic check flagged a persistent hardware interference or power-stage anomaly.
SMA Event 6501: Overtemperature Interior (Thermal Derating / Shutdown)
Internal chassis temperature exceeded maximum thermal ceiling, causing power derating or protective cooling pause.
SMA Event 6601: Self-Diagnosis — Overload / Software Overcurrent
Output stage software or hardware current monitoring tripped overload cutoff following utility step changes or DC-AC imbalance.
SMA Event 6701: Communication Processor Disturbed (CPU Fault)
Internal inverter communication processor experienced a watchdog reset or fault while managing portal and network tasks.
SMA Event 6801: Self-Diagnosis Input A Defective (DC Stage)
Startup self-diagnostics detected a hardware defect on PV String Input A boost or current-sensing stage.
SMA Event 6901: Self-Diagnosis Input B Defective (DC Stage)
Startup self-diagnosis detected an internal hardware defect on PV String Input B boost converter or current sensor.
SMA Event 7001: Interior Temp / Fan Sensor Fault (NTC Error)
Internal cabinet or fan NTC temperature probe reported an open/shorted signal outside calibrated limits.
SMA Event 7101: SD Card or Parameter File Defective
Corrupted FAT32 SD card or unreadable parameter/update file blocked local data logging or firmware loading.
SMA Event 7201: Internal Data Storage Error (EEPROM Fault)
On-board EEPROM or flash memory failed internal write verification or checksum reads for inverter parameters.
SMA Event 7301: Sub-Module Firmware Update Failed
Multi-stage firmware update failed to flash a sub-module inside the inverter cleanly.
SMA Event 7401: Varistor / DC Surge Protector Defective
Internal thermally monitored DC varistor surge suppressor opened safely after absorbing a rooftop overvoltage transient.
SMA Event 7501: Interior Cooling Fan Failure or Blocked Airflow
Cooling fan tachometer reported stalled blades or zero RPM under PWM drive, reducing midday heat tolerance.
SMA Event 7601: Internal IPC Communication Error
Failed internal IPC serial messaging between main power DSP and supervisory control boards halted system coordination.
SMA Event 7701: Self-Diagnosis Power Device Malfunction
Core power-stage hardware failed morning internal self-diagnosis, locking inverter synchronization safely offline.
SMA Event 7801: DC Surge Arrestor Fault (Type II SPD Tripped)
Internal Type II DC Surge Protection Device cartridge sacrificed safely during an overvoltage surge and requires replacement.
No fault codes match the active filter combination.