SMA Sunny Boy Error Codes & Fix Guides

German-engineered high-reliability residential and commercial string inverters. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.

SMA Sunny Boy Hardware Signal Topology

Solar Inverter
HV DCACPV Array StringsMPPT • AFCI • RisoDC Isolator & SPDSMA Sunny Boy CoreMPPT Boost • IGBT BridgeDual-CPU • RCMU • RelaysGrid & BreakerPLL Voltage / FreqRS485 CT & MainsComms & Smart MeterCAN / RS485 / Wi-FiPE Earth & Riso ⏚GFCI / Leakage Sensing

SMA Sunny Boy Diagnostic Profile (24 Codes)

DIY Safe (External): 7 (29%)Pro Only: 17
Auto-Recovering: 12 (50%)Latched: 12
Severity Distribution
● Crit 12● Warn/Med 11● Info/Low 1
OEM Manual Coverage: 100%OEM Portal ↗
Showing 24 / 24
Error 101
DIY SafeWarning

SMA Event 101: Grid Fault — High Grid Voltage / Line-Neutral Peak

Instantaneous AC phase voltage exceeded regional grid-code upper threshold, disconnecting feed-in safely.

Est. Cost: $0 - $240Fix Guide →
Error 102
DIY SafeWarning

SMA Event 102: Grid Fault — Upper Grid Voltage / Impedance Limit

Secondary upper AC grid threshold or rapid utility impedance shift tripped grid-protection disconnect.

Est. Cost: $0 - $240Fix Guide →
Error 202
DIY SafeWarning

SMA Event 202: Grid Fault — Low Grid Voltage or AC Disconnected

AC grid voltage dropped beneath regional lower limit or vanished completely due to open AC breaker or utility outage.

Est. Cost: $0 - $210Fix Guide →
Error 301
DIY SafeWarning

SMA Event 301: 10-Minute Rolling Mean Grid Voltage Exceeded

Ten-minute moving average utility grid voltage exceeded 110% regional statutory limit (~253V), triggering soft disconnection.

Est. Cost: $0 - $260Fix Guide →
Error 3501
Pro OnlyCritical

SMA Event 3501: Insulation Failure (PV Array Earth Ground Fault)

Measured DC string insulation resistance (`Riso`) dropped below safe safety margin before closing onto utility lines.

Est. Cost: $180 - $540Fix Guide →
Error 3601
Pro OnlyWarning

SMA Event 3601: High Discharge / Capacitive Leakage Current

Elevated capacitive earth-leakage current exceeded smooth steady thresholds during humid/rainy PV operation.

Est. Cost: $160 - $440Fix Guide →
Error 3701
Pro OnlyCritical

SMA Event 3701: Residual Current Too High (RCMU Fault Step)

Residual Current Monitoring Unit detected an acute earth-leakage step surge (`>=30 mA`) during live solar operation.

Est. Cost: $180 - $540Fix Guide →
Error 3801
Pro OnlyCritical

SMA Event 3801: DC Overcurrent Protection (Input A / B Surge)

PV string current exceeded maximum safe MPPT input rating, forcing boost stage protection cutoff.

Est. Cost: $180 - $520Fix Guide →
Error 3901
DIY SafeInfo

SMA Event 3901: Waiting for DC Start Conditions (Low Solar / ESS Off)

Informational status indicating rooftop PV DC voltage or available solar power sits below inverter startup wake threshold.

Est. Cost: $0 - $210Fix Guide →
Error 6400
Pro OnlyCritical

SMA Event 6400: Self-Diagnosis — Internal Device Disturbance

Internal firmware self-diagnostic check flagged a persistent hardware interference or power-stage anomaly.

Est. Cost: $0 - $520Fix Guide →
Error 6501
DIY SafeWarning

SMA Event 6501: Overtemperature Interior (Thermal Derating / Shutdown)

Internal chassis temperature exceeded maximum thermal ceiling, causing power derating or protective cooling pause.

Est. Cost: $0 - $180Fix Guide →
Error 6601
Pro OnlyCritical

SMA Event 6601: Self-Diagnosis — Overload / Software Overcurrent

Output stage software or hardware current monitoring tripped overload cutoff following utility step changes or DC-AC imbalance.

Est. Cost: $160 - $480Fix Guide →
Error 6701
Pro OnlyWarning

SMA Event 6701: Communication Processor Disturbed (CPU Fault)

Internal inverter communication processor experienced a watchdog reset or fault while managing portal and network tasks.

Est. Cost: $0 - $420Fix Guide →
Error 6801
Pro OnlyCritical

SMA Event 6801: Self-Diagnosis Input A Defective (DC Stage)

Startup self-diagnostics detected a hardware defect on PV String Input A boost or current-sensing stage.

Est. Cost: $0 - $520Fix Guide →
Error 6901
Pro OnlyCritical

SMA Event 6901: Self-Diagnosis Input B Defective (DC Stage)

Startup self-diagnosis detected an internal hardware defect on PV String Input B boost converter or current sensor.

Est. Cost: $0 - $520Fix Guide →
Error 7001
Pro OnlyWarning

SMA Event 7001: Interior Temp / Fan Sensor Fault (NTC Error)

Internal cabinet or fan NTC temperature probe reported an open/shorted signal outside calibrated limits.

Est. Cost: $0 - $340Fix Guide →
Error 7101
Pro OnlyWarning

SMA Event 7101: SD Card or Parameter File Defective

Corrupted FAT32 SD card or unreadable parameter/update file blocked local data logging or firmware loading.

Est. Cost: $80 - $220Fix Guide →
Error 7201
Pro OnlyCritical

SMA Event 7201: Internal Data Storage Error (EEPROM Fault)

On-board EEPROM or flash memory failed internal write verification or checksum reads for inverter parameters.

Est. Cost: $0 - $480Fix Guide →
Error 7301
Pro OnlyWarning

SMA Event 7301: Sub-Module Firmware Update Failed

Multi-stage firmware update failed to flash a sub-module inside the inverter cleanly.

Est. Cost: $0 - $190Fix Guide →
Error 7401
Pro OnlyCritical

SMA Event 7401: Varistor / DC Surge Protector Defective

Internal thermally monitored DC varistor surge suppressor opened safely after absorbing a rooftop overvoltage transient.

Est. Cost: $140 - $380Fix Guide →
Error 7501
DIY SafeWarning

SMA Event 7501: Interior Cooling Fan Failure or Blocked Airflow

Cooling fan tachometer reported stalled blades or zero RPM under PWM drive, reducing midday heat tolerance.

Est. Cost: $0 - $240Fix Guide →
Error 7601
Pro OnlyCritical

SMA Event 7601: Internal IPC Communication Error

Failed internal IPC serial messaging between main power DSP and supervisory control boards halted system coordination.

Est. Cost: $0 - $480Fix Guide →
Error 7701
Pro OnlyCritical

SMA Event 7701: Self-Diagnosis Power Device Malfunction

Core power-stage hardware failed morning internal self-diagnosis, locking inverter synchronization safely offline.

Est. Cost: $0 - $540Fix Guide →
Error 7801
Pro OnlyCritical

SMA Event 7801: DC Surge Arrestor Fault (Type II SPD Tripped)

Internal Type II DC Surge Protection Device cartridge sacrificed safely during an overvoltage surge and requires replacement.

Est. Cost: $150 - $380Fix Guide →