SMA Event 3901: Waiting for DC Start Conditions (Low Solar / ESS Off)
Affected Models: SMA Sunny Boy (SB 1.5–6.0 / US) & Sunny Tripower (STP 3.0–25000TL / Core1)
⚡ Quick Engineering Answer
SMA Sunny Boy • Error 3901SMA Event 3901 means Waiting for DC Start Conditions (Start conditions not met)—not an Input B overcurrent fault. DC string voltage or irradiance is below the minimum wake threshold (~100V–175V DC). Normal at dawn, dusk, or under snow; if frozen during sunny noon, inspect the bottom black SMA ESS handle and wall DC switch.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- Informational status indicating rooftop PV DC voltage or available solar power sits below inverter startup wake threshold.
- Trigger Threshold
- PV input voltage < startup threshold (~100V–175V DC) OR zero startup watts during cloudy/dusk conditions
- Recovery Window
- Auto-starts automatically within seconds once sunny irradiance builds above start floor or ESS switch closes
- Subsystem Affected
- PV String Voltage, External DC Rotary Switch & SMA ESS Grip
- Warranty Outlook
- Normal dusk/dawn notice costs $0; tripped rooftop fuses or cut animal string cables fall under array maintenance
How SMA Sunny Boy Error 3901 Triggers
Official SMA manuals classify Event 3901 (Waiting for DC start conditions) as a normal standby operational message rather than a hardware error. At twilight and sunrise, Sunny Boy and Sunny Tripower inverters pause here while array voltage sits under ~100V–175V DC or irradiance fails startup checks.
Seeing Event 3901 around sunrise or sunset requires zero action. Remaining stuck in 3901 under clear midday sun means DC power is disconnected—usually an open bottom ESS handle, turned-off wall DC rotary isolator, or open string fuse.
🔀 Hardware & Series Differences
Waiting for DC — insufficient morning light OR bottom black ESS DC handle pulled out)Ensure bottom black plastic ESS grip sits clicked firmly home and wall DC switch sits at ON.
Inspect battery SOC and DC breaker status if coupled storage remains stuck in standby.
🔍 Observable Symptoms
- •Green indicator blinks gently (
Wait) paired with informational Event 3901 inside Sunny Portal event logs. - •Logs harmlessly every single dawn, dusk, and during heavy snowstorms burying panels.
- •Concern only arises when Event 3901 stays frozen past 10:00 AM under full sun (
0Wproduction). - •WebUI displays
DC Voltage = 0Vduring daytime when external DC isolator or ESS grip was left OFF.
⚙️ Ranked Root Causes
Zero sunlight drops array voltage and wattage beneath startup minimum automatically.
ESS black plug slightly unseatedHighDisconnects rooftop array completely, holding DC terminals at zero volts even at bright noon.
One open rooftop connector breaks continuity across the whole string circuit.
<4–5 panels) unable to climb past minimum 125V–175V wake-up floorLowHeavy afternoon shade drops voltage on borderline short strings right underneath wake bounds.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightIf dawn, dusk, or heavy roof snow exists, take zero action—Event 3901 clears naturally.
Confirm exterior DC disconnect sits firmly ON and bottom black ESS plug rests fully seated.
Vpv String Voltages During Clear NoonIf wall switches sit ON at bright noon yet WebUI reads 0V, call an electrician for string repair.
Safe External Scope: Do Not Open Covers or Probe Terminals
All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.
🔧 Interactive Step-by-Step Diagnostic Checklist
Confirm Whether Event 3901 Occurred at Dawn/Dusk vs Bright Noon
Check Sunny Portal timestamps. If Event 3901 strictly shows up around sunrise, sunset, or snow-covered overcast hours, it is a 100% normal standby status message—no service needed.
Check Exterior DC Switch & Black Bottom ESS Plug Seating
Walk safely to the inverter and inspect only the outside rotary DC switch (must face ON) and check visually that the big bottom black SMA ESS grip isn't hanging unplugged or bumped loose (never pull ESS out under heavy noon load—only verify visually or push fully flush after switching AC OFF).
DC Voltage in Step 3.Read Sunny Portal / WebUI String Voltage & Contact Technician If 0V
View DC Voltage Input A/B inside WebUI or Energy App during full noon sunshine. Screenshot 0V or abnormally low values and contact your installer to check for chewed rooftop string wires or popped combiner fuses.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing Error 3901? Copy this structured engineering summary for your installer or OEM RMA ticket.
📋 Homeowner Preparation & Read-Only Access Needed
No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:
- ✓SMA Energy App / Sunny Portal
- ✓Visual Check of External DC Isolator Switch
❓ Frequently Asked Questions
Should I be worried if Sunny Portal logs Event 3901 every morning and evening?
Not at all! Event 3901 (Waiting for DC start conditions) simply records the everyday moment at sunrise and sunset when roof sunlight is slightly too weak to wake the inverter.
Why does Event 3901 stay on all day at 12:00 PM in full sunshine?
When Event 3901 stays stuck past mid-morning on a sunny day, DC power is interrupted before reaching the inverter—check whether an outdoor DC switch got turned off or a rooftop string wire came loose.
Does Event 3901 mean my DC Input B has overcurrent?
No—that's a widespread misprint on older third-party websites. In official SMA manuals, 3801 handles DC overcurrent while 3901 simply indicates low DC voltage waiting to start.
Related SMA Sunny Boy Fault Codes
PV string current exceeded maximum safe MPPT input rating, forcing boost stage protection cutoff.
AC grid voltage dropped beneath regional lower limit or vanished completely due to open AC breaker or utility outage.
Measured DC string insulation resistance (Riso) dropped below safe safety margin before closing onto utility lines.
Internal firmware self-diagnostic check flagged a persistent hardware interference or power-stage anomaly.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).