Error 3901Info✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

SMA Event 3901: Waiting for DC Start Conditions (Low Solar / ESS Off)

Affected Models: SMA Sunny Boy (SB 1.5–6.0 / US) & Sunny Tripower (STP 3.0–25000TL / Core1)

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 - $210 USD
Warranty may cover parts
Diag / Fix Time
5 - 30 mins
DC Startup Threshold & Array Shading

⚡ Quick Engineering Answer

SMA Sunny Boy • Error 3901

SMA Event 3901 means Waiting for DC Start Conditions (Start conditions not met)—not an Input B overcurrent fault. DC string voltage or irradiance is below the minimum wake threshold (~100V–175V DC). Normal at dawn, dusk, or under snow; if frozen during sunny noon, inspect the bottom black SMA ESS handle and wall DC switch.

Recovery Behavior:Normal operational waiting state that auto-clears once morning sunlight raises PV voltage past startup minimums (~125V–175V) or roof snow melts.
SCHEMATIC // SMA Sunny Boy Error 3901 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
SMA Sunny Boy Error 3901: PV Array, AFCI & DC Boost Stage System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PV Array, AFCI & DC Boost Stage
Signal / Power Path
Roof Strings / MC4 / Optimizers -> DC Isolator & MPPT
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Informational status indicating rooftop PV DC voltage or available solar power sits below inverter startup wake threshold.
Trigger Threshold
PV input voltage < startup threshold (~100V–175V DC) OR zero startup watts during cloudy/dusk conditions
Recovery Window
Auto-starts automatically within seconds once sunny irradiance builds above start floor or ESS switch closes
Subsystem Affected
PV String Voltage, External DC Rotary Switch & SMA ESS Grip
Warranty Outlook
Normal dusk/dawn notice costs $0; tripped rooftop fuses or cut animal string cables fall under array maintenance

How SMA Sunny Boy Error 3901 Triggers

Official SMA manuals classify Event 3901 (Waiting for DC start conditions) as a normal standby operational message rather than a hardware error. At twilight and sunrise, Sunny Boy and Sunny Tripower inverters pause here while array voltage sits under ~100V–175V DC or irradiance fails startup checks.

Seeing Event 3901 around sunrise or sunset requires zero action. Remaining stuck in 3901 under clear midday sun means DC power is disconnected—usually an open bottom ESS handle, turned-off wall DC rotary isolator, or open string fuse.

🔀 Hardware & Series Differences

SMA Sunny Boy & Sunny Tripower With ESS Handle
Event 3901 (Waiting for DC — insufficient morning light OR bottom black ESS DC handle pulled out)

Ensure bottom black plastic ESS grip sits clicked firmly home and wall DC switch sits at ON.

Battery / Sunny Boy Storage Systems
Low battery DC link voltage or solar string waiting for wake threshold

Inspect battery SOC and DC breaker status if coupled storage remains stuck in standby.

🔍 Observable Symptoms

  • •Green indicator blinks gently (Wait) paired with informational Event 3901 inside Sunny Portal event logs.
  • •Logs harmlessly every single dawn, dusk, and during heavy snowstorms burying panels.
  • •Concern only arises when Event 3901 stays frozen past 10:00 AM under full sun (0W production).
  • •WebUI displays DC Voltage = 0V during daytime when external DC isolator or ESS grip was left OFF.

⚙️ Ranked Root Causes

Normal dawn, dusk, deep overcast storms, or snow covering solar panels cleanlyHigh

Zero sunlight drops array voltage and wattage beneath startup minimum automatically.

Outdoor wall DC rotary isolator turned OFF or bottom SMA ESS black plug slightly unseatedHigh

Disconnects rooftop array completely, holding DC terminals at zero volts even at bright noon.

Broken series string connection, open combiner fuse, or chewed MC4 loop reducing DC input to 0VMedium

One open rooftop connector breaks continuity across the whole string circuit.

Excessively short solar string (<4–5 panels) unable to climb past minimum 125V–175V wake-up floorLow

Heavy afternoon shade drops voltage on borderline short strings right underneath wake bounds.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Sky Clarity, Heavy Snow & Time of Day First

If dawn, dusk, or heavy roof snow exists, take zero action—Event 3901 clears naturally.

2DC / BATT OFF
Check External Wall DC Rotary Isolator & SMA ESS Handle Position

Confirm exterior DC disconnect sits firmly ON and bottom black ESS plug rests fully seated.

3CHECK / VERIFY
Inspect WebUI Vpv String Voltages During Clear Noon

If wall switches sit ON at bright noon yet WebUI reads 0V, call an electrician for string repair.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Whether Event 3901 Occurred at Dawn/Dusk vs Bright Noon

Homeowner Safe

Check Sunny Portal timestamps. If Event 3901 strictly shows up around sunrise, sunset, or snow-covered overcast hours, it is a 100% normal standby status message—no service needed.

✓ Expected ResultAvoids needless service visits for routine twilight startup statuses.
→ If Fault PersistsMove to Step 2 ONLY if stuck all through cloudless sunny noon hours.
2

Check Exterior DC Switch & Black Bottom ESS Plug Seating

Homeowner Safe

Walk safely to the inverter and inspect only the outside rotary DC switch (must face ON) and check visually that the big bottom black SMA ESS grip isn't hanging unplugged or bumped loose (never pull ESS out under heavy noon load—only verify visually or push fully flush after switching AC OFF).

✓ Expected ResultFinds accidentally bumped DC switches or loose ESS grips safely from ground level.
→ If Fault PersistsCheck live WebUI DC Voltage in Step 3.
3

Read Sunny Portal / WebUI String Voltage & Contact Technician If 0V

Homeowner Safe

View DC Voltage Input A/B inside WebUI or Energy App during full noon sunshine. Screenshot 0V or abnormally low values and contact your installer to check for chewed rooftop string wires or popped combiner fuses.

✓ Expected ResultRestores broken rooftop series circuit or blown DC isolator continuity promptly.
→ If Fault PersistsSolar electrician inspects roof MC4 connectors and string fuses cleanly under lockout.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 3901? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓SMA Energy App / Sunny Portal
  • ✓Visual Check of External DC Isolator Switch

❓ Frequently Asked Questions

Should I be worried if Sunny Portal logs Event 3901 every morning and evening?

Not at all! Event 3901 (Waiting for DC start conditions) simply records the everyday moment at sunrise and sunset when roof sunlight is slightly too weak to wake the inverter.

Why does Event 3901 stay on all day at 12:00 PM in full sunshine?

When Event 3901 stays stuck past mid-morning on a sunny day, DC power is interrupted before reaching the inverter—check whether an outdoor DC switch got turned off or a rooftop string wire came loose.

Does Event 3901 mean my DC Input B has overcurrent?

No—that's a widespread misprint on older third-party websites. In official SMA manuals, 3801 handles DC overcurrent while 3901 simply indicates low DC voltage waiting to start.

Related SMA Sunny Boy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026