Error 202Warning✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

SMA Event 202: Grid Fault — Low Grid Voltage or AC Disconnected

Affected Models: SMA Sunny Boy (SB 1.5–6.0 / US) & Sunny Tripower (STP 3.0–25000TL / Core1)

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 - $210 USD
Warranty may cover parts
Diag / Fix Time
15 - 45 mins
AC Grid Loss & Undervoltage

⚡ Quick Engineering Answer

SMA Sunny Boy • Error 202

SMA Event 202 means Grid Fault — Low Grid Voltage or Utility Disconnection (do not confuse with frequency faults!). Triggered whenever utility lines brown out below ~195V–207V, a main Solar AC breaker trips, or someone switches off the external AC rotary isolator, Event 202 halts export cleanly. Check your main panel AC breaker status safely before waiting for utility recovery.

Recovery Behavior:Auto-clears automatically within 60–300 seconds once tripped AC breakers are restored or utility voltage climbs back above the lower grid cutoff.
SCHEMATIC // SMA Sunny Boy Error 202 — Grid-Tied String Inverter Architecture
PERIMETER: EXTERNAL CHECK
SMA Sunny Boy Error 202: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
AC grid voltage dropped beneath regional lower limit or vanished completely due to open AC breaker or utility outage.
Trigger Threshold
Utility AC line drops below configured undervoltage limit (<~195–207V) or 0V AC disconnect
Recovery Window
Auto-restarts 60–300 seconds once normal AC grid voltage stabilizes at terminals
Subsystem Affected
Main Solar AC Breaker, Outdoor AC Isolator & Utility Supply
Warranty Outlook
Tripped wall breakers or utility brownouts are external events; internal relay open fault covered if voltage confirmed outside

How SMA Sunny Boy Error 202 Triggers

Contrary to mislabeled charts online calling 202 an over-frequency alert, official SMA sunny-boy/tripower documentation designates Event 202 (and 203–206) as Grid Fault — Voltage Too Low / Grid Interruption. Whenever utility distribution voltage dips underneath configured minimums (~195V–207V on 230V systems) or the dedicated solar circuit breaker opens, the inverter immediately halts feed-in to uphold anti-islanding rules.

Utility Blackout vs. Tripped Solar Breaker: Notice when Event 202 strikes during sunny calm afternoons while all household lights and TVs keep working normally inside—your neighborhood utility grid is live, pointing directly to a tripped dedicated Solar AC breaker, bumped outdoor AC isolator, or loose external AC cable feeding just the inverter!

🔀 Hardware & Series Differences

SMA Sunny Boy Single-Phase
Event 202 (Grid voltage too low / Grid disconnected — AC V < minimum limit or 0V)

Verify main house Solar AC breaker & outdoor rotary AC isolator sit cleanly at ON.

SMA Sunny Tripower Three-Phase
Single-phase AC leg drop (0V blown fuse) or full building utility undervoltage

Inspect WebUI phase status—missing 1 of 3 phases typically flags a blown cartridge fuse in commercial disconnects.

🔍 Observable Symptoms

  • •Alternating red fault LED or Event 202 message in SMA Energy App alongside 0W solar export.
  • •Strikes instantly whenever neighborhood grid power flickers out or storms cause brownouts.
  • •House indoor outlets stay powered normally while inverter reads zero AC grid if dedicated solar breaker tripped.
  • •Resumes normal green solid light automatically moments after AC circuit restoration.

⚙️ Ranked Root Causes

Tripped dedicated Solar AC breaker in main distribution board or bumped exterior AC isolator switchHigh

Cuts incoming AC supply to zero volts cleanly while daytime panels keep control screen alive.

Utility substation brownout, blackout, or rural voltage dip during severe weatherHigh

External neighborhood distribution sags underneath lower SMA grid thresholds.

Blown single-phase fuse inside commercial 3-phase disconnect or loose AC plugMedium

Dropping one line drops inverter grid sensing immediately on Tripower units.

Heavy residential motor loads dragging long undersized subpanel feeder voltage temporarily lowLow

Large air compressors pull weak shared circuits under minimum trip volts.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Check Household Solar AC Breaker & Exterior AC Rotary Switch

Ensure the breaker labeled PV/Solar sits firmly ON and outdoor AC isolator is turned ON.

2DISCHARGE / WAIT
Verify Utility Outage Map & House Power Stability

Wait 15 minutes if neighborhood streetlights or local grid brownouts are occurring.

3DISCHARGE / WAIT
Run Clean AC-Then-DC Restart If Breaker Reset Holds

Wait 5 minutes after closing AC breaker so SMA completes standard anti-islanding check.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Check Dedicated Solar AC Breaker & Outdoor AC Switch

Homeowner Safe

Look at your home's electrical panel (without opening dead-front metal shields) to confirm the Solar / PV Inverter breaker isn't tripped midway/OFF, and check outdoors that any rotary AC isolator switch sits firmly at ON.

✓ Expected ResultFlipping a cleanly bumped or tripped breaker back ON restores grid power within 60–300 seconds.
→ If Fault PersistsIf the AC breaker snaps right back OFF immediately, leave it OFF and call an electrician right away!
2

Check Neighborhood Outage Alerts & Dimming Home Lights

Homeowner Safe

Confirm whether neighbors experienced utility blackouts, brownouts, or flickering lights around Event 202 timestamps inside Sunny Portal.

✓ Expected ResultUtility drops recover seamlessly on their own once utility crews restore clean power.
→ If Fault PersistsMove to Step 3 if street power stays solid while SMA Event 202 stays locked.
3

Cycle Inverter Once & Book Electrician Panel/Plug Audit

Homeowner Safe

Run one clean reboot (AC breaker OFF, DC switch OFF 5 minutes, turn DC ON then AC breaker ON). If Event 202 returns while lights in your home stay normal, book a licensed electrician to test terminal AC supply and check for blown commercial fuses.

✓ Expected ResultEliminates loose wall isolator connections or blown AC fuses cleanly.
→ If Fault PersistsElectrician verifies AC supply directly at SMA SUNCLIX plug and checks internal AC board via SMA Service.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 202? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓SMA Energy App / Sunny Portal
  • ✓Utility Outage Notification Portal

❓ Frequently Asked Questions

Why does my SMA inverter still light up with Event 202 even when my AC breaker is tripped?

During daylight, solar DC strings on your roof keep the SMA inverter screen, indicator LEDs, and WebUI awake—so it detects 0V at the AC terminals and faithfully displays Event 202: Grid disconnected.

My SMA AC breaker keeps tripping right back off when I flip it ON—what should I do?

Stop flipping it! Immediate breaker trips indicate an active short circuit, ground fault, or overcurrent event on the AC side. Leave the breaker OFF and summon a licensed solar electrician promptly.

How long does SMA wait to restart after Event 202 clears?

Depending on your regional Country Data Set (UL 1741, VDE, G98), SMA enforces a mandatory 60-to-300-second observation countdown before re-closing AC relays safely.

Related SMA Sunny Boy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians