SMA Event 6701: Communication Processor Disturbed (CPU Fault)

Affected Models: SMA Sunny Boy (SB 3.0–6.0 / -US) & Sunny Tripower (STP 5.0–25TL / X)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 - $420 USD
Warranty may cover parts
Diag / Fix Time
30 - 90 mins
Internal Communication Controller

⚡ Quick Engineering Answer

SMA Sunny Boy • Error 6701

SMA Event 6701 (Communication disturbed / Processor disturbed) flags an internal reset or memory stall in the inverter's Communication CPU handling WebUI, Speedwire/Ethernet, Modbus, and Sunny Portal logging. Usually solar output resumes once the watchdog reboots; chronic Event 6701 requires firmware updates or SMA comms-board replacement.

Recovery Behavior:Often auto-clears following an internal watchdog restart or one complete AC/DC power reset; chronic repeats indicate corrupted firmware or communication-board hardware failure.
SCHEMATIC // SMA Sunny Boy Error 6701 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
SMA Sunny Boy Error 6701: Smart Meter, BMS/RS485 & Portal Link System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Smart Meter, BMS/RS485 & Portal Link
Signal / Power Path
Telemetry Bus, CT Clamp / RS485 & Gateway Module
Safety Access Line
Sealed Chassis — Communication CPU, Speedwire/Wi-Fi Module & Flash Storage

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Internal inverter communication processor experienced a watchdog reset or fault while managing portal and network tasks.
Trigger Threshold
Communication processor heartbeat watchdog expires or throws kernel fault
Recovery Window
Typically self-restarts within 2–5 minutes; persistent faults lock WebUI access
Subsystem Affected
Communication CPU, Speedwire/Wi-Fi Module & Flash Storage
Warranty Outlook
High—defective internal comms assemblies qualify under SMA 5–10 year factory product warranty

How SMA Sunny Boy Error 6701 Triggers

Modern SMA Sunny Boy and Sunny Tripower inverters split grid-power DSP execution from an auxiliary Communication Controller (BFS/Comms CPU) hosting the WebUI dashboard, Wi-Fi/Ethernet interfaces, and Sunny Portal uploads.

Telemetry Dropout vs. Generation Impact: When memory corruption, network packet storms, or lightning-induced EMI freeze that communication controller, Event 6701 records as its hardware watchdog restarts the comms subsystem. Occasional isolated 6701 events clear seamlessly without interrupting solar production; however, persistent daily Event 6701 alongside frozen WebUI dashboards points to aging flash memory or defective comms assemblies requiring SMA service.

🔀 Hardware & Series Differences

SMA Sunny Boy & Sunny Tripower (-40/-41 WebUI Series)
Event 6701 (Communication processor disturbed — internal OS watchdog reboot or Comms CPU hang)

Verify SMA WebUI remains responsive and check latest firmware version under Device Parameters.

Legacy Sunny Boy TL-20 / TL-21 With Webconnect / Piggy-Back
Piggy-back communication module failure or intermittent backplane seat

Test rebooting inverter completely and verify Ethernet/Speedwire switch isn't flooding network packets.

🔍 Observable Symptoms

  • •Event 6701 logged in Sunny Portal or local WebUI Device Logbook.
  • •SMA Energy App / Sunny Portal reporting stalls for gaps while green LED often keeps generating power.
  • •Local browser WebUI (https://sma...) becomes sluggish or drops TCP connections unexpectedly.

⚙️ Ranked Root Causes

Transient communication OS watchdog reboot triggered by Wi-Fi/router packet storms or brownoutsHigh

Broadcast traffic or corrupted flash reads stall network daemon threads momentarily.

Outdated firmware containing known memory-leak or Webconnect TLS bugsMedium

Older firmware packages accumulate memory leaks over weeks before resetting via Event 6701.

Degrading internal NAND/flash sector or solder fatigue on SMA communication boardMedium

Heat stress causes repeated processor exceptions even with network cables unplugged.

Unshielded or damaged outdoor Ethernet run injecting EMI onto Speedwire PHY (low)Low

Induced spikes along long outdoor Ethernet cables disrupt communication transceiver stability.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Turn Solar AC Breaker OFF First

Disconnect external AC grid power safely at main distribution panel.

2DISCHARGE / WAIT
Turn Integrated DC Load-Break Switch to 0 (OFF)

Wait 5 full minutes until status LEDs and display extinguish completely.

3RESTORE & BOOT
Restore DC First, Then AC Breaker

Observe WebUI and Sunny Portal reconnection over the following 10 minutes.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Verify Whether Green Power Production Continues

Homeowner Safe

Check the external green operation LED on your SMA unit and power-cycle your home Wi-Fi router alongside one clean 5-minute AC/DC inverter reboot.

✓ Expected ResultConfirms whether Event 6701 was a harmless transient network watchdog reset.
→ If Fault PersistsIf Sunny Portal stays offline or Event 6701 repeats weekly, contact your SMA installer.
2

Disconnect External LAN Cable Briefly (If Hardwired)

Homeowner Safe

If connected via external outdoor Ethernet cable to a faulty home switch (accessible externally without opening covers), unplug/replug gently at the router side.

✓ Expected ResultIsolates router broadcast loops or port failures from internal SMA hardware.
→ If Fault PersistsPhotograph serial plate and export Event Logbook screenshots for SMA Online Service Center.
3

Update Firmware Package via Sunny Portal or Local WebUI

Licensed Technician

Verify active SMA firmware against current official releases on SMA.de and apply updates cleanly under steady daylight AC/DC stability.

✓ Expected ResultPatches known communication memory leaks causing periodic 6701 reboots.
→ If Fault PersistsRun isolated test with Ethernet disconnected and Wi-Fi off to confirm internal board fault.
4

Replace Communication Assembly or Process SMA Warranty Swap

Licensed Technician

With zero energy verified strictly per SMA Service Manual (5-min discharge + DC probe verification), replace failing comms module or process unit RMA.

✓ Expected ResultRestores uninterrupted Sunny Portal telemetry and eliminates Event 6701 resets.
→ If Fault PersistsUpdate Sunny Portal device serial registration smoothly after swap.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 6701? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •SMA Installer Access / Grid Guard
  • •Calibrated True-RMS Multimeter
  • •Ethernet Cable Tester
⚠️
Warning Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with SMA Sunny Boy Error 6701

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Does SMA Event 6701 stop my solar panels from making electricity?

Often no—Event 6701 tracks the auxiliary communications processor rather than the main power stage, though frequent processor hangs require checking production logs and updating firmware.

What does 'Processor disturbed' mean in Sunny Portal?

It logs an unexpected watchdog reset on the microprocessor running network, Webconnect, and Sunny Portal uploads, similar to restarting a frozen smart module.

Can outdated SMA firmware trigger Event 6701 repeatedly?

Yes. Enabling automatic updates or letting your installer push current SMA firmware clears several known WebUI/TLS communication reset bugs.

Related SMA Sunny Boy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026