SMA Event 3601: High Discharge / Capacitive Leakage Current

Affected Models: SMA Sunny Boy (SB 3.0–6.0) & Sunny Tripower (STP 5.0–25000TL / Core1)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$160 - $440 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Capacitive Array Earth Discharge (RCMU)

⚡ Quick Engineering Answer

SMA Sunny Boy • Error 3601

SMA Event 3601 (High discharge current) indicates Elevated Capacitive / Earth Discharge Current flowing across your transformerless solar array to ground (PE) during damp conditions or cloud transients. Large wet PV glass arrays naturally act as large capacitors against metal frames; check rain correlation first, then have a technician inspect array bonding and external 100–300 mA AC RCD selection.

Recovery Behavior:Normally clears autonomously in 60–300 seconds once wet glass panel capacitance stabilizes or drying weather reduces transient earth discharge.
SCHEMATIC // SMA Sunny Boy Error 3601 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
SMA Sunny Boy Error 3601: PE Ground Bond, RCMU & Array Riso System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PE Ground Bond, RCMU & Array Riso
Signal / Power Path
Rooftop Moisture Path, Differential Toroid & PE Earth
Safety Access Line
Sealed Chassis — Array Surface Capacitance, RCMU Toroid & Protective Earth Bond

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Elevated capacitive earth-leakage current exceeded smooth steady thresholds during humid/rainy PV operation.
Trigger Threshold
Measured steady capacitive / residual discharge current approaches upper RCMU continuous curve
Recovery Window
Auto-restarts in 60–300 seconds once heavy storm sheets drain off wet glass modules
Subsystem Affected
Array Surface Capacitance, RCMU Toroid & Protective Earth Bond
Warranty Outlook
Wet module capacitance / external wiring are site environmental conditions; defective RCMU CT is warranty

How SMA Sunny Boy Error 3601 Triggers

Transformerless SMA Sunny Boy and Sunny Tripower topologies directly couple fluctuating PV module capacitance against AC grid frequency. On dry sunny days, stray glass-to-frame array capacitance stays mild—but when rainstorms soak large arrays (especially frameless, dual-glass, or thin-film modules), water sheets enlarge the conductive surface area, pushing capacitive discharge current past Event 3601 thresholds.

Normal Wet Capacitance vs. Damaged Wire Insulation: While occasional Event 3601 pauses during torrential downpours clear safely once rainfall slows, repeated daily Event 3601 trips on gentle mornings warrant checking protective earth bonding (PE) alongside string insulation resistance (3501) and ensuring external wall AC RCD breakers aren't undersized at 30 mA.

🔀 Hardware & Series Differences

SMA Sunny Boy & Tripower Standard Crystalline Arrays
Event 3601 (High discharge current — steady/capacitive leakage surge across RCMU)

Verify weather/rain pattern and check Sunny Portal for paired 3501 (Riso) or 3701 (RCD step) logs.

Large Commercial / Glass-Glass / Frameless Bifacial Arrays
Natural wet surface capacitance spikes during storms or high-voltage switching

Requires solid array frame earthing and external AC RCCB rating >= 100–300 mA Type A/B (never 30 mA).

🔍 Observable Symptoms

  • •Amber warning or Event 3601 notifications trigger specifically during heavy rainstorms or intense coastal mist.
  • •Coincides sometimes with momentary dropouts lasting 1–5 minutes before self-reconnecting.
  • •Often accompanied by physical 30 mA external AC breaker trips if wrong wall RCD rating was installed.
  • •Zero faults during dry sunny afternoons.

⚙️ Ranked Root Causes

Rainwater coating large glass solar panels increasing capacitive leakage toward metal rackingHigh

Wet panel surfaces couple AC ripple voltage capacitively across array frames to PE earth.

Minor compromised string insulation or damp outdoor MC4 boots starting to weep current (pre-3501)High

Early water ingress adds resistive leakage atop normal rainy capacitance.

Loose or corroded PV array frame grounding (PE) bonding lugs creating discharge voltage driftMedium

Poor array earth continuity causes erratic common-mode leakage return pulses.

Hypersensitive external 30 mA wall AC RCD or faulty internal RCMU sensor bias (low)Low

Undersized AC RCCBs nuisance-trip simultaneously with minor RCMU capacitance pulses.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Verify Rainstorm / Dew Correlation Inside Energy App

Check if Event 3601 clears automatically once rain stops and panels dry off.

2SEQUENCE STEP
Confirm External AC Distribution Breaker Rating Visually

Note whether main solar breaker / wall RCD tripped off physically during rain.

3SEQUENCE STEP
Book Solar O&M Inspection If Events Occur on Dry Days

Dry-day 3601 trips require string Megger testing and array frame bonding verification.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Compare Rainfall Timing Against Sunny Portal Event Logs

Homeowner Safe

Review Sunny Portal fault timestamps to notice whether Event 3601 happens exclusively during downpours or heavy wet morning fog versus dry blue-sky hours.

✓ Expected ResultDistinguishes harmless heavy-rain capacitance spikes from chronic wiring degradation.
→ If Fault PersistsMove to Step 2 check for paired faults (3501 / 3701) and breaker behavior.
2

Audit Concurrent 3501/3701 Alerts & Wall Breaker Trips

Homeowner Safe

Check Sunny Portal history for paired Event 3501 (Insulation failure) or Event 3701 (Residual current), and check visually whether your external solar wall RCD snapped OFF.

✓ Expected ResultConfirms whether dry string testing or external wall RCD sizing needs technician attention.
→ If Fault PersistsSchedule Step 3 certified rooftop insulation and earth-bonding test.
3

Megger Test Isolated Strings, Check Array PE Bond & Audit AC RCD

Licensed Technician

Under complete AC/DC lockout, run 1000V DC Megger sweeps across individual solar strings (>1 MΩ required cleanly), inspect module/rail Protective Earth (PE) continuity back to main earth bar, check rooftop MC4 joints for early moisture entry, and confirm any external AC RCCB is sized per SMA spec (>=100–300 mA Type A/B, not 30 mA).

✓ Expected ResultSolid PE bonding, dry MC4 seals, and compliant external RCD end recurring rain cutouts.
→ If Fault PersistsInspect internal RCMU differential sensor via SMA Service if dry isolated strings still trigger 3601.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 3601? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Sunny Portal / Weather Timestamp Correlation
  • •1000V DC Megger & Earth Continuity Tester (Technician only)
⚠️
Warning Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with SMA Sunny Boy Error 3601

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Is Event 3601 normal during a heavy thunderstorm on my SMA inverter?

Occasional Event 3601 momentary drops during torrential downpours can occur on large wet glass arrays because water sheets increase natural capacitive discharge—though frequent trips on light morning dew warrant inspecting MC4 connectors.

Why does my wall GFCI/RCD breaker trip every time it rains with SMA Event 3601?

An electrician may have mistakenly wired a sensitive 30 mA residential bathroom-grade RCCB on the solar circuit instead of the SMA-specified 100 mA or 300 mA AC residual breaker.

How is Event 3601 related to Event 3501 and 3701?

All three guard against earth leakage: 3501 fails static morning Riso resistance, 3601 catches high steady wet capacitance/discharge, and 3701 reacts in milliseconds to dangerous sudden residual current jumps.

Related SMA Sunny Boy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026