SolarEdge Error Codes & Fix Guides

Industry-leading DC-optimized inverter systems with HD-Wave technology and power optimizers. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.

SolarEdge Hardware Signal Topology

Solar Inverter & Optimizers
HV DCACPV + OptimizersSafeDC • 1V/OptDC Isolator & SPDSolarEdge CoreHD-Wave Cap StageDual-CPU • RCMU • RelaysGrid & BreakerPLL Voltage / FreqRS485 CT & MainsComms & Smart MeterCAN / RS485 / Wi-FiPE Earth & Riso ⏚GFCI / Leakage Sensing

SolarEdge Diagnostic Profile (26 Codes)

DIY Safe (External): 9 (35%)Pro Only: 17
Auto-Recovering: 12 (46%)Latched: 14
Severity Distribution
● Crit 14● High 2● Warn/Med 10
OEM Manual Coverage: 100%OEM Portal ↗
Showing 26 / 26
Error 18x86
Pro OnlyCritical

SolarEdge Error 18x86: PV Isolation Fault (Earth Ground Leakage)

High-voltage DC string insulation resistance (`Riso`) dropped below safe earth isolation threshold on SetApp single-phase inverters.

Est. Cost: $180 - $520Fix Guide →
Error 8x58
Pro OnlyCritical

SolarEdge Error 8x58: Three-Phase / Synergy Array Isolation Fault

Three-phase / Synergy inverter detected earth leakage across parallel DC solar strings dropping isolation resistance below 1 MΩ.

Est. Cost: $240 - $680Fix Guide →
Error 18xC
Pro OnlyCritical

SolarEdge Error 18xC: DC Arc Fault Detected (AFCI Safety Lockout)

AFCI hardware detected electrical sparking on DC solar strings and safely locked out production to prevent fire.

Est. Cost: $200 - $560Fix Guide →
Error 3x11
Pro OnlyCritical

SolarEdge Error 3x11: Arc Detection Status Interrupt (AFCI Fault)

Platform arc-detection interrupt (`3x11`) locked out solar output after sensing DC electrical arc signatures.

Est. Cost: $200 - $550Fix Guide →
Error 18x8D
Pro OnlyHigh

SolarEdge Error 18x8D: AFCI Self-Test Failed (Arc Sensor Hardware Check)

Internal AFCI arc-detection circuit failed its morning wake-up self-verification test.

Est. Cost: $150 - $580Fix Guide →
Error 18xB5
Pro OnlyCritical

SolarEdge Error 18xB5: Internal DC/AC In-Stage Overvoltage (Hardware RMA)

Internal HD-Wave DC/AC in-stage capacitor bus overvoltage fault requiring warranty inverter replacement.

Est. Cost: $0 - $650Fix Guide →
Error 18xB7
Pro OnlyCritical

SolarEdge Error 18xB7: Internal DC/AC Out-Stage Overvoltage (Hardware Fault)

HD-Wave output conversion stage registered internal overvoltage (`DC/AC out-stage overvoltage`), requiring inverter replacement.

Est. Cost: $0 - $650Fix Guide →
Error 18xA6
Pro OnlyCritical

SolarEdge Error 18xA6: Tz Over Voltage (Internal Bus Capacitor Voltage Event)

Internal capacitor bank overvoltage (`Tz Over Voltage`) tripped conversion shutdown from capacitor aging or AC surge.

Est. Cost: $0 - $620Fix Guide →
Error 18x75
DIY SafeMedium

SolarEdge Error 18x75: Overtemp (Internal Thermal Protection Shutdown)

Inverter overheated and temporarily suspended or throttled output due to high ambient temperature or obstructed airflow.

Est. Cost: $0 - $240Fix Guide →
Error 18x37
DIY SafeMedium

SolarEdge Error 18x37: V-Line Max (AC Grid Voltage Too High)

AC line voltage exceeded regional Country Setup ceiling (`V-Line Max`), pausing solar production temporarily.

Est. Cost: $0 - $280Fix Guide →
Error 18x38
DIY SafeMedium

SolarEdge Error 18x38: V-Line Min (AC Grid Voltage Too Low / Brownout)

Incoming utility AC line voltage fell below regional Country Setup minimum (`V-Line Min`), halting export.

Est. Cost: $0 - $240Fix Guide →
Error 18x1D
Pro OnlyHigh

SolarEdge Error 18x1D: AC Line-to-Neutral Voltage Above Threshold (V_LN Max)

Line-to-Neutral AC voltage exceeded safe threshold from utility overvoltage, country mismatch, or loose neutral reference.

Est. Cost: $120 - $320Fix Guide →
Error 18x1E
DIY SafeMedium

SolarEdge Error 18x1E: AC Line-to-Neutral Voltage Below Threshold (V_LN Min)

Line-to-Neutral AC voltage fell below permissible lower threshold due to tripped breakers, brownouts, or poor neutral connection.

Est. Cost: $0 - $240Fix Guide →
Error 18x20
DIY SafeWarning

SolarEdge Error 18x20: AC Grid Voltage Below Country Limit (Vac Low)

AC output voltage fell below regional utility minimum, pausing export safely.

Est. Cost: $0 - $210Fix Guide →
Error 18x21
DIY SafeWarning

SolarEdge Error 18x21: AC Grid Voltage Above Limit (Vac High / Solar Rise)

AC line voltage exceeded regional overvoltage ceiling during export, pausing solar generation.

Est. Cost: $0 - $280Fix Guide →
Error 2x22
DIY SafeWarning

SolarEdge Error 2x22: AC Grid Frequency Above Limit (F_AC High)

AC line frequency exceeded configured utility ceiling, triggering anti-islanding halt.

Est. Cost: $0 - $190Fix Guide →
Error 2x23
DIY SafeWarning

SolarEdge Error 2x23: AC Grid Frequency Below Limit (F_AC Low)

Measured AC utility frequency dropped beneath regional minimum tolerance, pausing export to protect grid stability.

Est. Cost: $0 - $190Fix Guide →
Error 18x1A
Pro OnlyCritical

SolarEdge Error 18x1A: AC Grid Voltage Surge Transient (Vac Surge)

Instantaneous AC line voltage transient tripped hardware overvoltage protection, flagging potential surge-arrestor or loose-neutral hazard.

Est. Cost: $180 - $650Fix Guide →
Error 18xC7
Pro OnlyCritical

SolarEdge Error 18xC7: SafeDC Rapid Shutdown Test Failure (>30V DC)

SafeDC string voltage stayed above 30V DC during rapid shutdown verification on Energy Hub / SetApp inverters.

Est. Cost: $220 - $580Fix Guide →
Error 3x6E
Pro OnlyWarning

SolarEdge Error 3x6E: RS485 Energy Meter Communication Error

Inverter lost Modbus/RS485 telemetry link to the external Energy Meter, halting battery automation and zero-export control.

Est. Cost: $140 - $360Fix Guide →
Error 3x6A
Pro OnlyCritical

SolarEdge Error 3x6A: Inverter Remotely Locked / Safety Lock Active

Firmware security or critical safety lockout disabled inverter wake-up until authorized digital unlock via SolarEdge Portal / SetApp.

Est. Cost: $0 - $220Fix Guide →
Error 3xB
Pro OnlyCritical

SolarEdge Error 3xB: No Country or Grid Profile Configured (Error 44)

Required regional utility Grid Code profile is missing or reset to unconfigured default, blocking AC grid connection.

Est. Cost: $120 - $260Fix Guide →
Error 8x4F
Pro OnlyCritical

SolarEdge Error 8x4F: Wrong Three-Phase AC Wiring / Phase Rotation (Error 112)

Commercial three-phase inverter detected incorrect phase sequence, missing neutral reference, or AC wiring mismatch at startup.

Est. Cost: $180 - $480Fix Guide →
Error 8x2B
Pro OnlyCritical

SolarEdge Error 8x2B: Three-Phase Ground / RCD Current Surge Fault

Residual Current Monitoring Unit detected an acute AC/DC earth-leakage spike during live generation, halting inverter output.

Est. Cost: $220 - $590Fix Guide →
Error 2x1A
Pro OnlyCritical

SolarEdge Error 2x1A: Internal AC Relay Failure (Error 26 / Grid Switch Fault)

Mechanical AC grid isolation relay failed startup self-check (welded shut or failing to latch), halting export safely.

Est. Cost: $0 - $500Fix Guide →
Error 33xD
DIY SafeWarning

SolarEdge Error 33xD: Internal Cooling Fan Failure (Fan Fault)

Cooling fan tachometer reported stalled RPM or open circuit under PWM drive, reducing midday thermal capacity.

Est. Cost: $0 - $240Fix Guide →