Error 18xA6Critical⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

SolarEdge Error 18xA6: Tz Over Voltage (Internal Bus Capacitor Voltage Event)

Affected Models: SolarEdge Single-Phase HD-Wave, SetApp & Energy Hub Inverters

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$0 (Warranty RMA) - $620 (Out-of-Warranty Swap)
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Internal Capacitor Bank Supervision

⚡ Quick Engineering Answer

SolarEdge • Error 18xA6

SolarEdge Error 18xA6 (Tz Over Voltage) triggers when internal sensors detect excessive voltage across internal DC/AC bus capacitors (Cap 1 / Cap 2 / Cap 3), caused either by failing internal capacitor hardware, severe AC utility voltage spikes, or an incorrect Country/Grid profile. Check Country settings cleanly via SetApp once; persistent 18xA6 requires warranty RMA replacement.

Recovery Behavior:Usually marks permanent internal bus capacitor overvoltage or severe AC surge/country-code mismatch requiring service verification.
SCHEMATIC // SolarEdge Error 18xA6 — DC-Optimized String Inverter (SafeDC)
PERIMETER: SEALED ENCLOSURE
SolarEdge Error 18xA6: Internal Power Bridge, Capacitors & DSP System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDOptimizers / SafeDCMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Internal Power Bridge, Capacitors & DSP
Signal / Power Path
IGBT Bridge, DC-Link Capacitors, EEPROM & Dual-CPU
Safety Access Line
Sealed Chassis — Internal Multi-Level Capacitor Bank (Cap 1-3)

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Internal capacitor bank overvoltage (Tz Over Voltage) tripped conversion shutdown from capacitor aging or AC surge.
Trigger Threshold
Internal Cap 1 / Cap 2 / Cap 3 capacitor bus rail exceeds upper safety voltage limit
Recovery Window
Clears if caused strictly by transient grid spike/wrong grid code; hardware cap fault remains locked
Subsystem Affected
Internal Multi-Level Capacitor Bank (Cap 1-3)
Warranty Outlook
Covered under SolarEdge product warranty unless caused by extreme un-protected lightning surge

How SolarEdge Error 18xA6 Triggers

Inside SolarEdge's multi-stage power conversion stage, tri-stage internal capacitor groups (Cap 1, Cap 2, Cap 3) balance stepped DC link voltages continuously before AC synthesis. Error 18xA6 (Tz Over Voltage) flags immediately if voltage across any one capacitor bank climbs past safety limits—either due to asymmetrical capacitance loss inside the inverter or extreme AC line voltage spikes entering through wrong Country Grid configurations.

Official Triage Path: SolarEdge documentation splits diagnosis into two clear steps: verify first that SetApp Country/Grid Code settings match your true utility standard and inspect incoming utility AC lines for wild high spikes; if utility voltages read clean yet 18xA6 stays locked across a cold reboot, internal bus capacitor degradation demands warranty replacement.

🔀 Hardware & Series Differences

SolarEdge SetApp Single-Phase / HD-Wave
Tz Over Voltage across Cap 1/2/3 internal bus capacitor banks

Verify Country Code preset and AC terminal grid spikes first before submitting RMA.

Paired Hardware Progression (18xA6 -> 18xB5/18xB7)
Capacitor imbalance often escalates alongside in-stage/out-stage overvoltage alerts

Export complete fault history screenshots via SetApp for triage warranty approval.

🔍 Observable Symptoms

  • •Red LED illuminates continuously while inverter stops exporting solar kW.
  • •SetApp reports Error 18xA6: Tz Over Voltage in active faults.
  • •May coincide with local utility switching surges, lightning storms, or neighbor generator transients.
  • •Frequently accompanies intermittent 18x37 / 18x1A AC overvoltage events.

⚙️ Ranked Root Causes

Internal DC/AC bus capacitor imbalance or failing switching power componentHigh

Heat-aged capacitors drift in ESR/capacitance, sending asymmetrical voltage peaks across Cap 1/2/3.

Irregular high AC utility voltage surges or loose switchboard neutral spiking grid linesMedium

Utility transformer tap swings or dropped neutral elevate one leg's peak sine wave into internal bus.

Incorrect Country / Grid Standard preset configured during commissioningMedium

Applying a 208V commercial grid standard onto a 240V split-phase feed shifts bus operating ratios.

Internal voltage-sensing resistor drift on control DSPLow

Calibration failure reports spurious capacitor overshoot while true bus rests normal.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Flip Bottom Red P/1/0 Switch OFF, Then Solar AC Breaker OFF

Shut down conversion safely before turning utility breaker off.

2DC / BATT OFF
Turn DC Safety Switch OFF & Wait 5 Minutes Cleanly

Allow all Cap 1/2/3 internal bus banks to discharge completely.

3DC / BATT OFF
Turn DC ON, AC ON, Red Switch ON Once & Check Country Setting

If 18xA6 returns right away with verified clean AC mains, turn OFF for technician RMA.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Execute One 5-Minute Power Cycle & Note Recent Storms

Homeowner Safe

Turn bottom red toggle OFF (0), switch panel Solar AC OFF, switch DC Safety OFF for 5 full minutes, then power back up in reverse order and log whether lightning storms preceded the trip.

✓ Expected ResultSeparates rare transient grid spikes from permanent internal capacitor damage.
→ If Fault PersistsTurn inverter toggle OFF cleanly and call a SolarEdge certified technician.
2

Check Monitoring Voltage Logs & Serial Label

Homeowner Safe

Inspect mySolarEdge Monitoring graphs for suspicious high AC voltage spikes (>260V) right before 18xA6 logged, and photograph the inverter serial label for fast service filing.

✓ Expected ResultAlerts electrician right away if house utility voltage or neutral problems exist alongside inverter faults.
→ If Fault PersistsKeep unit turned OFF if household lights flicker unusually until electrician verifies mains.
3

Audit Country Grid Profile & Measure Mains L1/L2/N/PE Voltage

Licensed Technician

Test incoming AC supply lines, neutral-to-earth bonding, and switchboard terminal torque first; connect via SetApp to verify Country Code matches true local grid nominal voltage (120/240V, 208V, 230/400V).

✓ Expected ResultRules out external floating-neutral spikes or mis-configured regional presets.
→ If Fault PersistsVerify internal capacitor balance fault via SetApp fault logs after firmware verification.
4

Process Warranty RMA Exchange & Check Switchboard SPD

Licensed Technician

Submit diagnostic logs for permanent 18xA6 warranty replacement, mount fresh inverter unit cleanly onto Safety Switch, and fit Type-2 surge arresters externally if local grid surges triggered failure.

✓ Expected ResultStable safe operation with zero Tz Over Voltage cutoffs.
→ If Fault PersistsMonitor AC voltage daily via portal after replacement to catch utility surges early.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 18xA6? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •SolarEdge SetApp Mobile App
  • •Calibrated True-RMS Multimeter (Mains & Neutral Check)
  • •Torque Driver & RMA Unit Swap Hardware
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with SolarEdge Error 18xA6

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

What does 'Tz Over Voltage' mean on SolarEdge 18xA6?

Tz Over Voltage refers to excess voltage detected across the internal multi-stage capacitor bridge (Cap 1, Cap 2, Cap 3) inside your SolarEdge inverter—commonly requiring either grid/country verification or a warranty unit replacement.

Could a bad house neutral wire trigger SolarEdge Error 18xA6?

Yes! On 240V split-phase or three-phase homes, a loose utility neutral causes sudden violent voltage swings on one AC leg that overload internal capacitors unless fixed.

Can updating SolarEdge firmware fix Error 18xA6?

Only rarely if a false capacitor sensing spike occurred under early firmware; chronic 18xA6 alongside 18xB5/18xB7 indicates aged internal capacitors needing warranty swap.

Related SolarEdge Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026