SolarEdge Error 18xA6: Tz Over Voltage (Internal Bus Capacitor Voltage Event)
Affected Models: SolarEdge Single-Phase HD-Wave, SetApp & Energy Hub Inverters
⚡ Quick Engineering Answer
SolarEdge • Error 18xA6SolarEdge Error 18xA6 (Tz Over Voltage) triggers when internal sensors detect excessive voltage across internal DC/AC bus capacitors (Cap 1 / Cap 2 / Cap 3), caused either by failing internal capacitor hardware, severe AC utility voltage spikes, or an incorrect Country/Grid profile. Check Country settings cleanly via SetApp once; persistent 18xA6 requires warranty RMA replacement.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- Internal capacitor bank overvoltage (
Tz Over Voltage) tripped conversion shutdown from capacitor aging or AC surge. - Trigger Threshold
- Internal Cap 1 / Cap 2 / Cap 3 capacitor bus rail exceeds upper safety voltage limit
- Recovery Window
- Clears if caused strictly by transient grid spike/wrong grid code; hardware cap fault remains locked
- Subsystem Affected
- Internal Multi-Level Capacitor Bank (
Cap 1-3) - Warranty Outlook
- Covered under SolarEdge product warranty unless caused by extreme un-protected lightning surge
How SolarEdge Error 18xA6 Triggers
Inside SolarEdge's multi-stage power conversion stage, tri-stage internal capacitor groups (Cap 1, Cap 2, Cap 3) balance stepped DC link voltages continuously before AC synthesis. Error 18xA6 (Tz Over Voltage) flags immediately if voltage across any one capacitor bank climbs past safety limits—either due to asymmetrical capacitance loss inside the inverter or extreme AC line voltage spikes entering through wrong Country Grid configurations.
Official Triage Path: SolarEdge documentation splits diagnosis into two clear steps: verify first that SetApp Country/Grid Code settings match your true utility standard and inspect incoming utility AC lines for wild high spikes; if utility voltages read clean yet 18xA6 stays locked across a cold reboot, internal bus capacitor degradation demands warranty replacement.
🔀 Hardware & Series Differences
Tz Over Voltage across Cap 1/2/3 internal bus capacitor banksVerify Country Code preset and AC terminal grid spikes first before submitting RMA.
18xA6 -> 18xB5/18xB7)Export complete fault history screenshots via SetApp for triage warranty approval.
🔍 Observable Symptoms
- •Red LED illuminates continuously while inverter stops exporting solar kW.
- •SetApp reports
Error 18xA6: Tz Over Voltagein active faults. - •May coincide with local utility switching surges, lightning storms, or neighbor generator transients.
- •Frequently accompanies intermittent
18x37/18x1AAC overvoltage events.
⚙️ Ranked Root Causes
Heat-aged capacitors drift in ESR/capacitance, sending asymmetrical voltage peaks across Cap 1/2/3.
Utility transformer tap swings or dropped neutral elevate one leg's peak sine wave into internal bus.
Applying a 208V commercial grid standard onto a 240V split-phase feed shifts bus operating ratios.
Calibration failure reports spurious capacitor overshoot while true bus rests normal.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightShut down conversion safely before turning utility breaker off.
Allow all Cap 1/2/3 internal bus banks to discharge completely.
If 18xA6 returns right away with verified clean AC mains, turn OFF for technician RMA.
High-Voltage / Refrigerant Safety Boundary: Pro Service Split
Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.
🔧 Interactive Step-by-Step Diagnostic Checklist
Execute One 5-Minute Power Cycle & Note Recent Storms
Turn bottom red toggle OFF (0), switch panel Solar AC OFF, switch DC Safety OFF for 5 full minutes, then power back up in reverse order and log whether lightning storms preceded the trip.
Check Monitoring Voltage Logs & Serial Label
Inspect mySolarEdge Monitoring graphs for suspicious high AC voltage spikes (>260V) right before 18xA6 logged, and photograph the inverter serial label for fast service filing.
Audit Country Grid Profile & Measure Mains L1/L2/N/PE Voltage
Test incoming AC supply lines, neutral-to-earth bonding, and switchboard terminal torque first; connect via SetApp to verify Country Code matches true local grid nominal voltage (120/240V, 208V, 230/400V).
Process Warranty RMA Exchange & Check Switchboard SPD
Submit diagnostic logs for permanent 18xA6 warranty replacement, mount fresh inverter unit cleanly onto Safety Switch, and fit Type-2 surge arresters externally if local grid surges triggered failure.
Tz Over Voltage cutoffs.📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing Error 18xA6? Copy this structured engineering summary for your installer or OEM RMA ticket.
🧰 Field Reference: What Your Technician Will Inspect
For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:
- •SolarEdge SetApp Mobile App
- •Calibrated True-RMS Multimeter (Mains & Neutral Check)
- •Torque Driver & RMA Unit Swap Hardware
Don't Risk High-Voltage Shock with SolarEdge Error 18xA6
This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:
❓ Frequently Asked Questions
What does 'Tz Over Voltage' mean on SolarEdge 18xA6?
Tz Over Voltage refers to excess voltage detected across the internal multi-stage capacitor bridge (Cap 1, Cap 2, Cap 3) inside your SolarEdge inverter—commonly requiring either grid/country verification or a warranty unit replacement.
Could a bad house neutral wire trigger SolarEdge Error 18xA6?
Yes! On 240V split-phase or three-phase homes, a loose utility neutral causes sudden violent voltage swings on one AC leg that overload internal capacitors unless fixed.
Can updating SolarEdge firmware fix Error 18xA6?
Only rarely if a false capacitor sensing spike occurred under early firmware; chronic 18xA6 alongside 18xB5/18xB7 indicates aged internal capacitors needing warranty swap.
Related SolarEdge Fault Codes
Internal HD-Wave DC/AC in-stage capacitor bus overvoltage fault requiring warranty inverter replacement.
HD-Wave output conversion stage registered internal overvoltage (DC/AC out-stage overvoltage), requiring inverter replacement.
Instantaneous AC line voltage transient tripped hardware overvoltage protection, flagging potential surge-arrestor or loose-neutral hazard.
Required regional utility Grid Code profile is missing or reset to unconfigured default, blocking AC grid connection.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).