Error 2x23Warning✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

SolarEdge Error 2x23: AC Grid Frequency Below Limit (F_AC Low)

Affected Models: SolarEdge SetApp HD-Wave, Legacy LCD & Three-Phase Synergy (2x23 / 18x23)

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 - $190 USD
Warranty may cover parts
Diag / Fix Time
15 - 40 mins
AC Grid Frequency Under-Frequency

⚡ Quick Engineering Answer

SolarEdge • Error 2x23

SolarEdge Error 2x23 (also shown as 18x23 on newer SetApp firmware) signals AC Grid Frequency Below Lower Limit (<47.5–49.5 Hz on 50 Hz networks or <59.3 Hz on 60 Hz grids). Most often caused by heavy regional grid strain, generator bog-downs, or wrong Country grid profile selection, it clears automatically once frequency normalizes.

Recovery Behavior:Recovers automatically in 60–300 seconds once regional grid frequency stabilizes back above the lower grid-code threshold.
SCHEMATIC // SolarEdge Error 2x23 — DC-Optimized String Inverter (SafeDC)
PERIMETER: EXTERNAL CHECK
SolarEdge Error 2x23: Smart Meter, BMS/RS485 & Portal Link System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDOptimizers / SafeDCMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Smart Meter, BMS/RS485 & Portal Link
Signal / Power Path
Telemetry Bus, CT Clamp / RS485 & Gateway Module
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Measured AC utility frequency dropped beneath regional minimum tolerance, pausing export to protect grid stability.
Trigger Threshold
Utility AC frequency dips below regional lower trip threshold (~47.5–49.5 Hz on 50Hz grid or ~57.0–59.3 Hz on 60Hz)
Recovery Window
Auto-clears 60–300 seconds once grid Hz climbs cleanly inside country reconnection range
Subsystem Affected
Grid Frequency PLL, Country Profile & Utility Generation Balance
Warranty Outlook
Utility under-frequency faults are external grid conditions; PLL hardware clock failure falls under warranty

How SolarEdge Error 2x23 Triggers

Grid frequency falls below 50.00 Hz or 60.00 Hz whenever total neighborhood electrical consumption briefly surpasses active utility generation capacity—for instance during utility substation trip cascades, severe storms, or bogged-down local microgrids. As a safeguard under IEEE 1547 and EN 50549 anti-islanding standards, SolarEdge raises Error 2x23 (AC Frequency Too Low) and isolates its output relays.

Single-Phase vs. Generator / Microgrid Bog-Downs: Outside major utility emergencies, persistent Error 2x23 notifications commonly show up during generator transitions when heavy inductive compressor loads drag engine RPM downward, or at new commissioning sites where an installer accidentally selected an overly narrow frequency band or incorrect Country Code inside SetApp.

🔀 Hardware & Series Differences

SolarEdge SetApp & HD-Wave Inverters
Error 2x23 / 18x23 (AC Frequency Too Low below country lower trip band)

Verify SetApp Grid Code (IEEE 1547-2018, Rule 21, EN 50549) matches utility interconnection rules.

Backup Interface / Weak Rural & Island Grids
Triggered during under-frequency utility load-shedding events or microgrid overload sags

Check frequency ride-through settings if utility permits wide frequency tolerances.

🔍 Observable Symptoms

  • •Red fault LED paired with Error 2x23 / 18x23 notifications following severe regional grid dips or storms.
  • •Often coincides momentarily with flickering home appliances, motor hums, or neighborhood brownouts.
  • •Usually disappears within 5–10 minutes after utility substations shed load or rebalance frequency.
  • •Loops repeatedly during initial installation if wrong Country Grid Code (e.g., 60 Hz set on 50 Hz grid) is stored.

⚙️ Ranked Root Causes

Temporary regional grid generation deficit or severe weather switching on high-voltage substationsHigh

Utility frequency drops momentarily below trip threshold during emergency substation load transfer.

Engine-driven generator bogging down under heavy appliance startup currentHigh

Heavy inrush drags standby generator speed below nominal 50/60 Hz limits.

Wrong Country / Grid Profile configuration applied inside SetAppMedium

Wrong nominal frequency or hyper-sensitive custom frequency threshold disconnects on minor grid wobble.

Faulty AC zero-crossing sense reference on inverter main control board (rare)Low

Drifted timing oscillator miscalculates normal utility Hz and refuses grid sync.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Observe Regional Utility Stability for 10 Minutes

Allow automatic reconnection countdown once weather or substation switching settles.

2CHECK / VERIFY
Check mySolarEdge Event Frequency Log

Look for exact Hz trip points during fault timestamps to verify utility dip vs inverter misread.

3AC ISOLATE
Run Single Clean Power Cycle If Still Hung

Flip bottom red P/1/0 switch OFF (0), turn AC breaker OFF 3 minutes, then reverse ON and wait 300s.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Utility Disturbance or Bad Weather Timing

Homeowner Safe

Check regional utility outage updates and review mySolarEdge notifications for exact trip timestamps. Notice whether neighborhood lights dimmed or motors slowed simultaneously around the same second.

✓ Expected ResultVerifies grid-side disturbance; inverter clears 2x23 automatically within 5 minutes of stable power.
→ If Fault PersistsIf weather is calm and neighboring grids run cleanly, continue to Step 2.
2

Perform One Clean Red-Switch & AC Breaker Reboot

Homeowner Safe

Move the bottom red P/1/0 toggle switch to 0 (OFF), turn your Solar AC breaker OFF for 3 minutes, then turn the AC breaker ON first and switch P/1/0 back to 1 (ON). Allow a full 5 minutes for rapid-blink grid sync.

✓ Expected ResultBlinking green transitions smoothly to steady green export without immediate 2x23 re-trip.
→ If Fault PersistsMove to Step 3 to inspect grid profile accuracy.
3

Screenshot Logs & Request Country Grid Code Verification

Homeowner Safe

Capture screenshots of repeated Error 2x23 alerts in mySolarEdge and note whether this error started immediately after initial commissioning or firmware updates. Forward logs to your installer to verify Country Grid Profile and PLL accuracy.

✓ Expected ResultInstaller applies correct regional SetApp profile or schedules hardware support if clock circuit drifted.
→ If Fault PersistsInstaller contacts SolarEdge Support with inverter serial number and AC frequency logs.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 2x23? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓mySolarEdge Monitoring App
  • ✓Utility Outage Notification Portal

❓ Frequently Asked Questions

Can I change the Country Grid Code myself to stop Error 2x23?

No. Grid profile settings are protected inside installer-only SetApp access to protect utility workers and maintain regional interconnection compliance. Contact your installer if your region code was set wrongly.

Why did Error 2x23 and Error 18x20 show up together during a storm?

During heavy transmission line faults or brownouts, both utility voltage and line frequency collapse together just before power goes out, logging 18x20 (low voltage) alongside 2x23 (low frequency).

Does Error 2x23 always reset by itself?

Yes, provided the home sits on normal public utility power. As soon as line frequency stays inside limits for the regional reconnection timer (often 60–300 seconds), SolarEdge clears Error 2x23 automatically.

Related SolarEdge Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).