Error #26Critical⚡ Pro Only (No Cover Open)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Victron SmartSolar Error #26: Terminal Overheated

Affected Models: Victron SmartSolar MPPT 100/50, 150/45–100, 250/60–100 (Screw Terminal 'Tr' and MC4 Models)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$80 - $320 USD
Warranty may cover parts
Diag / Fix Time
45 - 90 mins
DC Terminal Thermal Protection

⚡ Quick Engineering Answer

Victron Energy • Error #26

Victron SmartSolar Error #26 means the internal power terminals or PCB terminal connection area overheated dangerously—nearly always caused by loose screw clamps, oxidized fine wire strands, missing ferrules on Tr models, or undersized solar/battery cables. Switch PV and Battery isolators OFF immediately; re-terminating high-current lugs safely requires proper torque tools.

Recovery Behavior:Auto-resets once terminals cool below thermal threshold, though melting risk persists until loose or undersized power wiring is repaired.
SCHEMATIC // Victron Energy Error #26 — 48V Battery & MultiPlus/MPPT DC Bus
PERIMETER: SEALED ENCLOSURE
Victron Energy Error #26: Internal Power Bridge, Capacitors & DSP System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Internal Power Bridge, Capacitors & DSP
Signal / Power Path
IGBT Bridge, DC-Link Capacitors, EEPROM & Dual-CPU
Safety Access Line
Sealed Chassis — PV & Battery DC Power Terminal Block

📊 Technical Specification & Trigger Matrix

Official Manual Definition
MPPT power terminal temperature sensor detected dangerous overheating at the PV or battery terminal connections.
Trigger Threshold
Internal terminal sensor exceeds safe hardware temperature rating (~85°C–100°C)
Recovery Window
Auto-restarts once cooled, but re-trips every peak solar noon until torque/cables are repaired
Subsystem Affected
PV & Battery DC Power Terminal Block
Warranty Outlook
Melted terminal blocks caused by loose installer wiring are excluded from manufacturer warranty

How Victron Energy Error #26 Triggers

High continuous amperage (30A to 100A+) flowing into battery terminals creates rapid resistive I²R heating whenever contact surface area shrinks even slightly. Victron SmartSolar units embed temperature monitoring right beside the DC connection terminals to arrest thermal runaway before plastic blocks melt or start electrical fires.

Error #26 virtually never stems from ambient air temperature alone—unlike general heatsink derating. Instead, loose clamp screws on Tr compression blocks, broken copper strands stuffed into screw clamps without bootlace ferrules, tarnished aluminum-copper joints, or severely undersized cables generate pinpoint terminal heat that exceeds thermal cutoff. Left ignored, repeated thermal trips char housing polycarbonate beyond repair.

🔀 Hardware & Series Differences

SmartSolar 'Tr' Compression Screw Terminal Models
Overheating from untinned, un-ferruled fine-strand wire settling under clamp screws

Fine Class 5 flexible cable compresses over months unless crimped with solid insulated ferrules and re-torqued.

Large High-Current Chassis (150/85, 150/100, 250/100)
Heat conduction from loose M8 lug nuts, external breaker resistance, or undersized 4–6 AWG cable

Verify minimum 35 mm² (2 AWG) wiring with proper hydraulic lug crimps on 85–100A controllers.

🔍 Observable Symptoms

  • •VictronConnect stops solar charging near peak midday sun and displays Error #26.
  • •Faint hot-plastic smell or discoloration visible around green/black DC terminal shroud.
  • •Error disappears late afternoon or early morning once sun diminishes.
  • •Internal temperature graph climbs steeply proportional to charging amperage squared.

⚙️ Ranked Root Causes

Under-torqued screw terminals or vibration-loosened DC clamp boltsHigh

RVs, boats, and mobile installations vibrate un-checked screw clamps loose over miles/waves.

Fine-strand flexible copper splayed out or used without bootlace ferrulesHigh

Fewer than 50% of copper strands carry 50A–100A load, driving intense focal heating.

Undersized battery or PV wire gauge operating near ampacity limitsMedium

Thin cables heat up externally and conduct high heat directly into MPPT terminal screws.

Corrosion, oxidation, or defective internal PCB terminal solder jointLow

Damp bilge air oxidizes bare copper ends inside compression clamps.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1SEQUENCE STEP
Switch Off PV Solar Isolator Immediately

Stop current flowing through the hot terminal before melting occurs.

2AC ISOLATE
Switch Off Battery DC Breaker Safely

Allow controller terminals 30 minutes to cool back down completely.

3CHECK / VERIFY
Inspect Externally Without Touching Bare Conductors

Look for darkened plastic or loose jacket insulation before calling an installer for torque repair.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Isolate PV & Battery Switches & Review Charge Currents

Homeowner Safe

Turn off your external PV and battery disconnect switches to halt heating safely, then inspect VictronConnect History to record peak daily wattage and amps prior to Error #26.

✓ Expected ResultPrevents terminal plastic charring or fire hazard immediately.
→ If Fault PersistsNever rely on auto-reset recovery to run again tomorrow under full midday sun.
2

Visually Check Enclosure Airflow & Surrounding Breakers

Homeowner Safe

Look without touching exposed conductors whether DC breakers or adjacent combiner boxes show scorched wire insulation or extreme ambient confinement.

✓ Expected ResultIdentifies confined unventilated compartments or nearby loose breaker heat sources.
→ If Fault PersistsSchedule a qualified marine/solar electrician with calibrated torque tools.
3

De-Energize DC, Strip & Re-Terminate All 4 Power Conductors

Licensed Technician

Isolate and verify 0V DC on both PV and battery sides, remove wires, trim away any tarnished or brittle heat-damaged copper back to bright clean strands, verify cable gauge matches Victron spec, and crimp copper/bootlace ferrules where recommended.

✓ Expected ResultHeat-oxidized high-resistance ends are completely eliminated.
→ If Fault PersistsIf green plastic terminal housing itself is cracked/melted, replace the controller unit safely.
4

Torque Terminal Screws to Exact Victron Spec & Thermal Check

Licensed Technician

Tighten all PV and battery terminals cleanly to the exact Nm torque printed inside the Victron manual (e.g., 1.2–2.4 Nm depending on chassis), wait 10 minutes, check settling, and inspect under full midday current with a thermal camera.

✓ Expected ResultTerminals remain cool (<45°C rise above ambient) through continuous rated output.
→ If Fault PersistsPersistent terminal heating at calibrated torque and clean lugs indicates internal PCB solder-joint failure requiring RMA.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error #26? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Calibrated Insulated Torque Screwdriver
  • •Thermal Imaging Camera / IR Thermometer
  • •Bootlace Ferrule Crimper & Replacement Wire
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Victron Energy Error #26

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Is Victron Error #26 dangerous to leave running if it auto-resets overnight?

Yes—very. Auto-resetting simply means the plastic cooled overnight; each sunny afternoon will heat the loose joint hotter until copper oxidizes and melts the housing or starts an electrical fire.

Why do Victron Tr terminals come loose after installation?

Fine-stranded copper slowly cold-flows under screw pressure over time—especially inside vans/boats exposed to road vibration—requiring ferrules and periodic re-torque checks.

Can tight cupboard enclosures alone cause Error #26?

High cupboard heat usually causes smooth solar derating rather than sudden Error #26 shutdowns; Error #26 almost always involves resistance heating directly at the wire connection.

Related Victron Energy Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).