Growatt Error 120: HCT Internal Current Sensor Fault

Affected Models: Growatt MIN TL-X/XH, MOD TL3-X, MID, MAX & SPH Hybrid Series

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$0 - $480 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Internal Current Sensing Hardware

⚡ Quick Engineering Answer

Growatt • Error 120

Growatt Error 120 (HCT Fault) alerts an internal Hall Current Transducer / Output Current Sensor Failure. Even with zero grid power flowing at startup, internal current sensors reported abnormal DC offset current above safety limits. Try one full 10-minute AC/DC/Battery shutdown reset; repeated Error 120 requires technician verification and Growatt RMA board/unit replacement.

Recovery Behavior:Inverter halts generation permanently whenever internal Hall-effect Current Transducer (HCT) zero-offset readings drift outside safe bounds.
SCHEMATIC // Growatt Error 120 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Growatt Error 120: Internal Power Bridge, Capacitors & DSP System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Internal Power Bridge, Capacitors & DSP
Signal / Power Path
IGBT Bridge, DC-Link Capacitors, EEPROM & Dual-CPU
Safety Access Line
Sealed Chassis — Hall Current Transducer (HCT), +/-15V Op-Amp Rail & ADC Sense

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Internal Hall-effect output current sensor failed startup zero-current offset calibration check.
Trigger Threshold
Zero-current HCT ADC offset deviates beyond calibration ceiling during pre-relay check
Recovery Window
Transient EMI trips may clear on 10-minute dark reboot; drifted sensors stay locked permanently
Subsystem Affected
Hall Current Transducer (HCT), +/-15V Op-Amp Rail & ADC Sense
Warranty Outlook
High—failed HCT sensors/auxiliary rails qualify directly under Growatt warranty replacement

How Growatt Error 120 Triggers

Accurate AC current and DC-injection cancellation depend on factory-calibrated Hall-effect Current Transducers (HCT) soldered directly around high-power copper output conductors inside Growatt MIN, MOD, and SPH inverters. Each morning before closing AC relays, firmware checks zero-load baseline readings from every HCT sensor.

Error 120 (HCT Fault) fires if zero-current baseline values wander too far due to failed ±15V internal op-amp power rails, cracked HCT magnetic cores, or surge damage on current-sense analog amplifiers.

🔀 Hardware & Series Differences

Growatt MIN / TL-X / TL-XH Single-Phase
Output Hall Current Sensor zero-offset out of spec (HCT Fault) prior to grid relay closure

Occasionally appears alongside Error 121 or Error 120 sub-codes when auxiliary +/-15V rail sags.

Growatt MOD / MID / SPH Hybrids
AC Inverter / EPS / Backup output HCT sensor channel offset out of tolerance

On hybrids, heavy backup inductive overload spikes can shock current sensors—always disconnect heavy EPS loads during reset tests.

🔍 Observable Symptoms

  • •Solid red LED with Error 120 / HCT Fault frozen continuously on OLED.
  • •Zero watts generated even under cloudless morning skies.
  • •Shutdown resets restore green blink briefly before crashing straight back to Error 120 prior to export.
  • •May trigger after severe lightning surges or external inductive load spikes on hybrid backup outputs.

⚙️ Ranked Root Causes

Failed internal Hall-effect Current Transducer (HCT) IC or cracked ferrite sensing ringHigh

Permanent magnetic/op-amp drift sends bogus current signals at zero amps.

Collapsed internal +/-12V/15V analog sensor supply rail on power boardHigh

Bad regulator capacitor starves current transducer bias power on startup.

External high-frequency surge or heavy backup EPS short shock-latching current ADCMedium

Severe inductive transients corrupt sensor bias temporarily until full power bleed.

Loose internal ribbon cable linking power stage HCT signals to DSP control boardLow

Open sense harness floats analog ADC pin full-scale.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Switch Off Backup Load Breakers (If SPH Hybrid) & Grid AC Breaker

Isolate AC grid and EPS loads cleanly before resetting sensor baselines.

2DC / BATT OFF
Switch Battery OFF & PV DC Rotary Switch OFF for 10 Minutes

Allow screen to turn totally blank so analog op-amp supply rails bleed down to zero volts.

3RESTORE & BOOT
Turn ON PV DC -> Battery -> AC & Monitor Startup

If Error 120 returns at zero load immediately, shut system off and contact installer.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Isolate Backup Loads (If Hybrid) & Run Full 10-Min Cold Reboot

Homeowner Safe

Turn OFF external EPS/backup breakers if running an SPH hybrid, turn OFF AC solar breaker, Battery, and PV DC rotary switch for 10 full minutes until OLED fades totally dark, then turn PV, Battery, and AC back ON in sequence.

✓ Expected ResultTransient sensor latch clears cleanly and green production status recovers.
→ If Fault PersistsImmediate Error 120 recurrence signals internal sensor or +/-15V rail failure—go to Step 2.
2

Document Model SN & Error History for Installer RMA

Homeowner Safe

Photograph side Serial Number (SN) label, firmware revision from ShinePhone, and Error 120 alerts, then send details to your Growatt installer for warranty service verification.

✓ Expected ResultSpeeds Growatt RMA case creation without missing metadata.
→ If Fault PersistsProceed to Step 3 certified technician ribbon/power-stage evaluation.
3

Inspect Sensor Harnesses & Process Growatt Power-Stage RMA

Licensed Technician

Under complete AC/DC/Battery lockout and verified <50V DC-bus discharge, check HCT board ribbon connectors if Growatt tech support approves field cover opening; otherwise capture external AC/DC open-circuit checks and submit full replacement RMA packet.

✓ Expected ResultReplacing faulty HCT power module or swap chassis clears Error 120 permanently.
→ If Fault PersistsReplace complete unit under warranty and verify external EPS loads stay within continuous ratings.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 120? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Phone Camera (Side SN Label & OLED Error 120)
  • •True-RMS Multimeter & Growatt Service RMA Portal (Technician only)
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Growatt Error 120

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Is Growatt Error 120 caused by my external smart meter CT clamp being backwards?

No. Reversed external CT clamps affect export readings or battery charge logic, whereas Error 120 specifically monitors the soldered internal Hall Current Transducer built onto Growatt's main power board.

Can restarting my Growatt inverter fix Error 120 permanently?

A full 10-minute shutdown occasionally clears an analog latch caused by a storm transient, but repeated Error 120 across reboots means an internal sensor component or op-amp power supply failed.

Should I run the inverter on backup mode when Error 120 is active?

You cannot—Growatt intentionally locks out both grid-tie AC export and EPS backup paths because it cannot safely regulate output current without accurate HCT current feedback.

Related Growatt Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026