Error 117Critical⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

Growatt Error 117: Internal AC Relay Fault (Grid Switch Failure)

Affected Models: Growatt MIN TL-X/XH, MOD TL3-X, MID, MAX & SPH Hybrid Series

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$0 - $520 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Internal AC Isolation Relay Protection

⚡ Quick Engineering Answer

Growatt • Error 117

Growatt Error 117 (Relay Fault) means the internal mechanical AC Output Isolation Relay failed startup verification—either contacts welded closed or relay drive coils failed to snap shut when commanded. Perform one clean 10-minute cold reboot first; if Error 117 returns immediately, a technician must verify external AC terminals before Growatt approves a warranty board or unit RMA.

Recovery Behavior:Redundant AC relay self-test locks output permanently once contacts weld or fail feedback checks; hard rebooting rarely clears repeated physical relay wear.
SCHEMATIC // Growatt Error 117 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Growatt Error 117: AC Protection Relays, Breaker & Grid System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
Sealed Chassis — Dual AC Grid Isolation Relays & Auxiliary Coil Power Rail

📊 Technical Specification & Trigger Matrix

Official Manual Definition
AC grid isolation relay failed self-test feedback check at boot, freezing power export for anti-islanding safety.
Trigger Threshold
Relay feedback voltage differs from expected open/closed state during startup self-test
Recovery Window
Physical welded or open-coil relays stay permanently locked until board/unit RMA replacement
Subsystem Affected
Dual AC Grid Isolation Relays & Auxiliary Coil Power Rail
Warranty Outlook
High—covered under Growatt 5–10 year factory product warranty once external AC wiring passes

How Growatt Error 117 Triggers

Every grid-tied Growatt inverter isolates solar stages from public utility wires via dual series mechanical AC safety relays. Before closing onto the grid after the 60-second safety countdown, microprocessors test whether each relay opens and closes independently without sticking.

Error 117 (alongside Warning/Error 405 on select firmware variants) triggers whenever relay feedback voltage fails that startup safety gate—commonly after high-current lightning transients weld silver relay contacts or aging coil drivers weaken over thousands of morning startup cycles.

🔀 Hardware & Series Differences

Growatt MIN / SPH / TL-X Single-Phase
Error 117 (AC Relay Fault — dual Live/Neutral relays failed pre-sync check)

Verify external AC breaker did not drop one line/neutral leg before claiming internal RMA.

Growatt MOD / MID Three-Phase
One or more R/S/T phase relays failed coil actuation or contact welding test (117 / 405)

Listen for normal crisp relay click during countdown; silence or double-chatter points to PCB power supply or relay failure.

🔍 Observable Symptoms

  • •Red LED illuminates immediately right after audible startup relay click tests conclude.
  • •Zero watts produced in bright sun across multiple restart attempts.
  • •Often starts immediately after nearby lightning storms or utility transformer spikes.
  • •Quickly returns straight to Error 117 within seconds of every morning boot.

⚙️ Ranked Root Causes

Electrically welded or heavily carbonized mechanical AC relay contacts inside power boardHigh

Lightning spikes or years of high-current relay closures fuse silver contacts shut.

Failed relay driver transistor or depleted 12V auxiliary drive power railHigh

Coil lacks clean switching voltage to pull armature closed inside self-test timeout.

Partially open AC isolator or burnt single Neutral/Line connection outside inverterMedium

Loose wall isolator plugs interrupt AC feedback across one side of the relay bridge.

Cracked solder joints on heavy power-stage AC relay pins from thermal cyclingLow

Heat expansion fatigues PCB traces feeding relay sense inputs.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Confirm Main Solar AC Breaker Sits Firmly ON

Check main panel to confirm breaker did not snap partway off.

2AC ISOLATE
Execute One Clean 15-Minute Complete Shutdown

Turn OFF AC breaker, battery switch, and bottom PV DC rotary switch until display goes black 15 minutes.

3RESTORE & BOOT
Turn ON DC -> Battery -> AC & Observe Countdown Once

If Error 117 returns straight after relay click, turn unit OFF and request installer RMA check.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Verify Main AC Breaker & Run Single 15-Minute Cold Cycle

Homeowner Safe

Ensure your Solar AC breaker is latched fully ON, then run one full shutdown: turn AC OFF, Battery OFF, and PV DC OFF for 15 minutes until OLED goes completely dark, then reverse back ON.

✓ Expected ResultTransient processor confusion clears cleanly if relays weren't physically welded.
→ If Fault PersistsImmediate recurrence proves physical relay hardware or external AC wiring fault—go to Step 2.
2

Capture Serial Label, Warranty Proof & Alert Photos

Homeowner Safe

Photograph the side inverter Serial Number (SN) label alongside the Error 117 display message and ShinePhone alert timestamp before scheduling your installer.

✓ Expected ResultArms service tech with full RMA package details prior to truck roll.
→ If Fault PersistsSchedule Step 3 qualified technician AC terminal voltage check.
3

Verify Incoming AC Terminal Voltages & Submit Growatt RMA

Licensed Technician

Confirm full balanced AC grid voltage reaches the inverter's waterproof AC plug/terminal block cleanly (eliminating wall isolators or burnt breaker lugs), inspect for physical burn odor on power board if opened under LOTO, and upload multimeter test values to Growatt RMA portal.

✓ Expected ResultExternal AC verification clears warranty approval for power-board or full inverter swap.
→ If Fault PersistsInstall replacement unit under warranty and verify Type-2 SPD protection exists at main service panel.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 117? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Phone Camera (Side SN Barcode & Error 117 Screen)
  • •True-RMS Multimeter & LOTO Kit (Technician only)
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Growatt Error 117

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Can an electrician replace just the relay inside a Growatt inverter for Error 117?

Typically no—Growatt warranty centers ship complete replacement units or full power/control board assemblies rather than soldering component-level relays outdoors.

Why won't repeated power resets make Error 117 go away?

Once physical metal relay contacts fuse together inside the sealed relay cube, software cannot separate them. Repeated resets simply trigger the same safety fail-open check cleanly.

Could a bad wall AC isolator switch mimic Growatt Error 117?

Yes! If water corrodes one terminal inside your outdoor rotary AC switch, voltage fails to pass evenly to the inverter relay test circuit—which is why technicians test incoming AC plug voltage first.

Related Growatt Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).