Growatt Error 117: Internal AC Relay Fault (Grid Switch Failure)
Affected Models: Growatt MIN TL-X/XH, MOD TL3-X, MID, MAX & SPH Hybrid Series
⚡ Quick Engineering Answer
Growatt • Error 117Growatt Error 117 (Relay Fault) means the internal mechanical AC Output Isolation Relay failed startup verification—either contacts welded closed or relay drive coils failed to snap shut when commanded. Perform one clean 10-minute cold reboot first; if Error 117 returns immediately, a technician must verify external AC terminals before Growatt approves a warranty board or unit RMA.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- AC grid isolation relay failed self-test feedback check at boot, freezing power export for anti-islanding safety.
- Trigger Threshold
- Relay feedback voltage differs from expected open/closed state during startup self-test
- Recovery Window
- Physical welded or open-coil relays stay permanently locked until board/unit RMA replacement
- Subsystem Affected
- Dual AC Grid Isolation Relays & Auxiliary Coil Power Rail
- Warranty Outlook
- High—covered under Growatt 5–10 year factory product warranty once external AC wiring passes
How Growatt Error 117 Triggers
Every grid-tied Growatt inverter isolates solar stages from public utility wires via dual series mechanical AC safety relays. Before closing onto the grid after the 60-second safety countdown, microprocessors test whether each relay opens and closes independently without sticking.
Error 117 (alongside Warning/Error 405 on select firmware variants) triggers whenever relay feedback voltage fails that startup safety gate—commonly after high-current lightning transients weld silver relay contacts or aging coil drivers weaken over thousands of morning startup cycles.
🔀 Hardware & Series Differences
AC Relay Fault — dual Live/Neutral relays failed pre-sync check)Verify external AC breaker did not drop one line/neutral leg before claiming internal RMA.
117 / 405)Listen for normal crisp relay click during countdown; silence or double-chatter points to PCB power supply or relay failure.
🔍 Observable Symptoms
- •Red LED illuminates immediately right after audible startup relay click tests conclude.
- •Zero watts produced in bright sun across multiple restart attempts.
- •Often starts immediately after nearby lightning storms or utility transformer spikes.
- •Quickly returns straight to
Error 117within seconds of every morning boot.
⚙️ Ranked Root Causes
Lightning spikes or years of high-current relay closures fuse silver contacts shut.
Coil lacks clean switching voltage to pull armature closed inside self-test timeout.
Loose wall isolator plugs interrupt AC feedback across one side of the relay bridge.
Heat expansion fatigues PCB traces feeding relay sense inputs.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightCheck main panel to confirm breaker did not snap partway off.
Turn OFF AC breaker, battery switch, and bottom PV DC rotary switch until display goes black 15 minutes.
If Error 117 returns straight after relay click, turn unit OFF and request installer RMA check.
High-Voltage / Refrigerant Safety Boundary: Pro Service Split
Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.
🔧 Interactive Step-by-Step Diagnostic Checklist
Verify Main AC Breaker & Run Single 15-Minute Cold Cycle
Ensure your Solar AC breaker is latched fully ON, then run one full shutdown: turn AC OFF, Battery OFF, and PV DC OFF for 15 minutes until OLED goes completely dark, then reverse back ON.
Capture Serial Label, Warranty Proof & Alert Photos
Photograph the side inverter Serial Number (SN) label alongside the Error 117 display message and ShinePhone alert timestamp before scheduling your installer.
Verify Incoming AC Terminal Voltages & Submit Growatt RMA
Confirm full balanced AC grid voltage reaches the inverter's waterproof AC plug/terminal block cleanly (eliminating wall isolators or burnt breaker lugs), inspect for physical burn odor on power board if opened under LOTO, and upload multimeter test values to Growatt RMA portal.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing Error 117? Copy this structured engineering summary for your installer or OEM RMA ticket.
🧰 Field Reference: What Your Technician Will Inspect
For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:
- •Phone Camera (Side SN Barcode & Error 117 Screen)
- •True-RMS Multimeter & LOTO Kit (Technician only)
Don't Risk High-Voltage Shock with Growatt Error 117
This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:
❓ Frequently Asked Questions
Can an electrician replace just the relay inside a Growatt inverter for Error 117?
Typically no—Growatt warranty centers ship complete replacement units or full power/control board assemblies rather than soldering component-level relays outdoors.
Why won't repeated power resets make Error 117 go away?
Once physical metal relay contacts fuse together inside the sealed relay cube, software cannot separate them. Repeated resets simply trigger the same safety fail-open check cleanly.
Could a bad wall AC isolator switch mimic Growatt Error 117?
Yes! If water corrodes one terminal inside your outdoor rotary AC switch, voltage fails to pass evenly to the inverter relay test circuit—which is why technicians test incoming AC plug voltage first.
Related Growatt Fault Codes
Mechanical AC grid isolation relays failed open/close self-diagnostics prior to synchronization, locking output safely.
Redundant DSP and slave safety microcontrollers measured mismatched voltage or frequency samples during pre-sync check.
Inverter sees zero incoming utility AC voltage at its grid port due to a utility outage, tripped breaker, or open isolator.
High-voltage IGBT switching driver circuit reported desaturation/overcurrent fault, shutting down power conversion.
Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).