Growatt Error Codes & Fix Guides
One of the world's most widely installed residential solar inverters (MIN, MIC, SPH, and SPF series). Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Growatt Hardware Signal Topology
Growatt Diagnostic Profile (30 Codes)
Growatt Error 102: Consistent Fault (Dual-CPU Sampling Mismatch)
Redundant DSP and slave safety microcontrollers measured mismatched voltage or frequency samples during pre-sync check.
Growatt Error / Warning 111: Neutral-Earth Fault, Export Comms or IGBT Check
Model-specific fault flagging Neutral-to-Earth voltage deviation, smart-meter export limitation failure, or legacy IGBT gate fault.
Growatt Error 117: Internal AC Relay Fault (Grid Switch Failure)
AC grid isolation relay failed self-test feedback check at boot, freezing power export for anti-islanding safety.
Growatt Error 120: HCT Internal Current Sensor Fault
Internal Hall-effect output current sensor failed startup zero-current offset calibration check.
Growatt Error 121: Internal Communication / Processor Fault
Internal SPI/UART handshake dropped between main DSP processor and communication/auxiliary control module.
Growatt Error 129: AC Voltage Out of Range / Output Abnormal
Detected utility AC voltage climbed above or sagged below configured regional safety thresholds, pausing grid feed-in.
Growatt Error 130: AC Grid Frequency Out of Range (AC F Outrange)
Utility grid frequency drifted past regional 50 Hz / 60 Hz safety limits, pausing AC generation cleanly.
Growatt Warning / Error 201: Residual Leakage Current Too High (GFCI)
Internal GFCI current transformer sensed hazardous residual earth leakage exceeding safety cutoff.
Growatt Error / Warning 202: PV Voltage High (DC Input Overvoltage)
Combined PV string open-circuit voltage exceeded safe inverter DC maximum limit, locking conversion to protect DC bus capacitors.
Growatt Error / Warning 203: PV Isolation Low (Low Riso Earth Fault)
Low insulation resistance detected between rooftop PV conductors and Protective Earth ground prior to startup synchronization.
Growatt Warning / Error 204: Dry Contact Fault or PV Polarity Reversed
Auxiliary dry-contact control logic anomaly or reversed PV string DC polarity preventing safe array wake-up.
Growatt Warning / Error 205: PV1 or PV2 Boost Converter Broken
Hardware failure inside the DC-DC MPPT boost stage for PV1 or PV2, blocking safe energy lift onto the internal DC bus.
Growatt Warning 206: AC Surge Protection Device (SPD) Abnormal
Thermal disconnect flag on internal/modular AC Surge Protection Device signaled a sacrificial varistor blowout or open feedback loop.
Growatt Warning 207: USB / U-Disk Over-Current Protection
USB/Datalogger port 5V supply rail tripped electronic over-current fuse protection due to shorted logger or flash drive.
Growatt Warning 208: DC String Fuse Open or Sampling Fault
Blown rooftop string DC gPV fuse detected (or model-specific internal string sampling discrepancy), halving that MPPT input.
Growatt Error 300: AC V Outrange (Grid Voltage Out of Range)
AC grid voltage measured outside programmed regional upper or lower safety thresholds, opening grid relays.
Growatt Error 301: AC Terminals Reversed (Live / Neutral Polarity Swap)
Swapped AC Line and Neutral wiring polarity detected at the inverter output terminals, locking synchronization.
Growatt Error 302: No AC Connection (Utility Grid or Breaker Loss)
Inverter sees zero incoming utility AC voltage at its grid port due to a utility outage, tripped breaker, or open isolator.
Growatt Error 303: NE Abnormal (Neutral-to-Earth Voltage Fault)
Excessive AC voltage difference (>30V) measured between Neutral and Protective Earth conductors, halting output safely.
Growatt Warning 401: Inverter Communicates with Meter Abnormal
Lost RS485 Modbus communication between Growatt inverter and external export/consumption Smart Meter.
Growatt Warning 404: EEPROM Read/Write & Bus Sample Fault
Non-volatile EEPROM checksum corruption or DC bus sampling failure prevented startup calibration verification.
Growatt Warning 405: Relay Fault (Grid Isolation Relay Failure)
Mechanical AC grid isolation relays failed open/close self-diagnostics prior to synchronization, locking output safely.
Growatt Error 407: Auto Test Failed (Compliance Self-Test Fault)
Automated utility protection self-test sequence aborted or exceeded trip-time limits under grid-code compliance checks.
Growatt Error 409: Bus Overvoltage (Internal DC Link Volt High)
Internal inverter DC bus voltage surged beyond component safety limits during operation or cold solar startup.
Growatt Error 411: DSP & M3 Internal Processor Comm Fault
Lost internal serial link between main DSP power processor and slave M3 safety microcontroller.
Growatt Warning 412: Temp Sensor / Internal Connection Abnormal
Internal NTC thermistor telemetry drifted outside physically possible temperature limits or lost harness continuity.
Growatt Error 413: IGBT Drive Fault (Power Stage Failure)
High-voltage IGBT switching driver circuit reported desaturation/overcurrent fault, shutting down power conversion.
Growatt Error 417: DSP-M3 Protocol Version Mismatch
DSP power controller and M3 safety processor are running incompatible firmware versions after partial update.
Growatt Error 418: DSP & COM Controller Firmware Unmatch
Incompatible firmware revisions detected between the main DSP inverter board and the COM communication board.
Growatt Warning 420: GFCI Module Damage (Leakage Sensor Fault)
Internal GFCI/RCD residual current transformer failed its startup self-calibration check, disabling output safely.
No fault codes match the active filter combination.