Growatt Error 300: AC V Outrange (Grid Voltage Out of Range)

Affected Models: Growatt MIN TL-X/XH, MIC, MOD TL3-X/XH, MID, MAX & SPH/SPA Hybrid

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 - $260 USD
Warranty may cover parts
Diag / Fix Time
30 - 90 mins
Utility Grid Voltage Protection

⚡ Quick Engineering Answer

Growatt • Error 300

Growatt Error 300 (AC V Outrange) means utility AC voltage climbed above or dipped below the inverter's configured grid-code limits (commonly >253V–264V or <195V on 230V systems). Dense midday neighborhood solar export or undersized AC cable runs push terminal voltage too high; brief utility spikes auto-recover, whereas chronic midday trips require installer AC checks or grid-code tuning.

Recovery Behavior:Inverter monitors utility voltage automatically and reconnects after 60–300 seconds once AC voltage returns inside regional grid-code bounds.
SCHEMATIC // Growatt Error 300 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Growatt Error 300: Smart Meter, BMS/RS485 & Portal Link System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Smart Meter, BMS/RS485 & Portal Link
Signal / Power Path
Telemetry Bus, CT Clamp / RS485 & Gateway Module
Safety Access Line
Sealed Chassis — Grid Voltage Sensing, AC Output Cable & Country Profile

📊 Technical Specification & Trigger Matrix

Official Manual Definition
AC grid voltage measured outside programmed regional upper or lower safety thresholds, opening grid relays.
Trigger Threshold
AC terminal voltage outside country limits (e.g., >253V–264V or <180V–196V)
Recovery Window
Auto-reconnects in 60–300s once AC voltage stabilizes
Subsystem Affected
Grid Voltage Sensing, AC Output Cable & Country Profile
Warranty Outlook
Site cable size and street grid voltage are outside warranty; internal ADC drift is covered

How Growatt Error 300 Triggers

Grid-tied and hybrid Growatt units constantly sample line-to-neutral and phase-to-phase voltage at their AC output connector. Whenever local utility voltage surges at solar noon or droops during evening peak demand past the active country standard (VDE, G98, CEI, UL 1741, or AS/NZS 4777), Error 300 (AC V Outrange) pauses export cleanly.

Transformer Swell vs. Cable Voltage Rise: If ShinePhone hourly telemetry shows AC voltage climbing steadily with kW output (11:00–14:30), thin AC wiring between the main panel and inverter or high street transformer tap voltage is driving peak voltage across the shutdown line.

🔀 Hardware & Series Differences

Growatt MIN / MIC / SPH Single-Phase
Error 300 (AC V Outrange — Line-to-Neutral voltage outside grid-code ceiling/floor)

Inspect exact Vac snapshot in ShinePhone fault log to separate overvoltage (>253V) from undervoltage (<196V).

Growatt MOD / MID / MAX Three-Phase
Grid voltage excursion on L1, L2, or L3 phase above/below threshold

Single-phase rise on only one leg highlights unbalanced neighborhood load or a loose neutral connection.

🔍 Observable Symptoms

  • •Red warning indicator alongside AC V Outrange (300) on Growatt OLED/LCD.
  • •Predictable midday solar shutdowns between late morning and mid-afternoon.
  • •Recovers automatically within minutes when clouds roll over or heavy home appliances turn on.

⚙️ Ranked Root Causes

Midday utility feeder overvoltage caused by neighborhood solar backfeedHigh

Street transformer voltage swells above national ceilings when export exceeds local consumption.

Long or undersized AC run causing excess voltage rise at full kWHigh

Thin AC cable adds resistive drop (I x R) at inverter terminals during high export.

Incorrect Country Grid Standard or disabled Volt-Watt / Volt-Var deratingMedium

Strict legacy grid-code profiles trip abruptly instead of tapering reactive power smoothly.

Loose AC terminal lug creating high contact resistance (low)Low

Oxidized breaker or AC plug contacts spike terminal voltage under heavy current flow.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Open ShinePhone Event Log Before Cycling Power

Screenshot the timestamped Vac value reported alongside Error 300.

2DISCHARGE / WAIT
Observe Automatic 5-Minute Grid Recovery

Wait up to 300 seconds during cloudy breaks or load changes before manually toggling.

3DISCHARGE / WAIT
Perform One AC-First Reboot Only If Display Hangs

Turn AC breaker OFF, wait 5 minutes until dark, then restore AC to resync readings.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Check ShinePhone Voltage History & Time Pattern

Homeowner Safe

Open the Growatt ShinePhone app and note what Vac voltage and time of day Error 300 repeats.

✓ Expected ResultEvents cluster at sunny midday peaks (overvoltage) or utility storm hours (brownout).
→ If Fault PersistsShare screenshots with your installer so grid-side voltage rise can be isolated from hardware drift.
2

Compare Neighbor Outages & Home Utility Stability

Homeowner Safe

Verify whether household lights flicker or neighboring solar owners see utility voltage disturbances simultaneously.

✓ Expected ResultWidespread events point straight to street feeder swings rather than internal inverter failure.
→ If Fault PersistsContact your utility provider for a line voltage log check if feeder voltage exceeds local statutory limits.
3

Measure Panel vs Inverter AC Voltage Under Load

Licensed Technician

Isolate circuits per lockout rules, verify tight AC plug and breaker torque, and compare AC voltage at main panel versus inverter terminals under export.

✓ Expected ResultDifference between panel and inverter terminals stays within ~1–2% voltage rise.
→ If Fault PersistsUpsize AC feeder gauge or torque loose distribution lugs to remove ohmic voltage rise.
4

Audit Country Grid Code & Power Quality Settings

Licensed Technician

Inspect active Country Code in ShineServer / ShineTools and enable utility-approved Volt-Watt P(U) or Volt-Var Q(U) curves where permitted.

✓ Expected ResultInverter tapers reactive/active export smoothly instead of snapping off at Error 300.
→ If Fault PersistsIf calibrated meter readings diverge >3V from inverter telemetry, submit Growatt sensing-board ticket.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 300? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Calibrated True-RMS Multimeter
  • •Torque Screwdriver
  • •Growatt ShineTools App
⚠️
Warning Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Growatt Error 300

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Why does Growatt Error 300 happen mostly around noon on sunny days?

Around midday, neighborhood solar export pushes street voltage up while home usage is low, crossing the upper regional cutoff (~253V–264V). Turning on heavy loads or evening drops usually restores export automatically.

Can I fix Error 300 by turning off the AC breaker repeatedly?

No. Error 300 already auto-recovers within 60–300 seconds once utility voltage settles; repeated breaker toggling will not keep it online if midday street voltage or AC wire resistance stays high.

Does Error 300 mean my Growatt inverter is broken?

Usually no—Error 300 indicates the protection relay is functioning correctly to comply with grid safety laws. Only inaccurate internal sensing compared against a meter indicates hardware drift.

Related Growatt Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians