Growatt Error 413: IGBT Drive Fault (Power Stage Failure)

Affected Models: Growatt MIN TL-X/XH, MOD TL3-X/XH, MID, MAX & SPH/SPA Hybrid

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$0 - $550 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Power Stage & IGBT Drive Protection

⚡ Quick Engineering Answer

Growatt • Error 413

Growatt Error 413 (IGBT Drive Fault) flags a critical hardware fault in the high-voltage IGBT / MOSFET inverter power stage or its isolated gate-driver circuitry (DESAT protection tripped). Because firing damaged IGBTs risks catastrophic shorts, Error 413 locks out permanently after lightning or overload surges—requiring factory warranty replacement.

Recovery Behavior:Permanent hardware safety lockout protecting inverter semiconductors; requires authorized technician testing and full power-board or unit RMA.
SCHEMATIC // Growatt Error 413 — Grid-Tied String Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Growatt Error 413: Internal Power Bridge, Capacitors & DSP System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceOptional StorageDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Internal Power Bridge, Capacitors & DSP
Signal / Power Path
IGBT Bridge, DC-Link Capacitors, EEPROM & Dual-CPU
Safety Access Line
Sealed Chassis — Power Bridge IGBT Modules, Gate Driver ICs & Isolated Power Supply

📊 Technical Specification & Trigger Matrix

Official Manual Definition
High-voltage IGBT switching driver circuit reported desaturation/overcurrent fault, shutting down power conversion.
Trigger Threshold
Gate driver DESAT overcurrent or missing +/-15V isolated gate drive rail
Recovery Window
Hardware fault—rarely clears after one cold cycle; normally permanently locked
Subsystem Affected
Power Bridge IGBT Modules, Gate Driver ICs & Isolated Power Supply
Warranty Outlook
High—covered under Growatt 5–10 year factory warranty unless external lightning surge burned boards

How Growatt Error 413 Triggers

Inside the power bridge of Growatt MIN, MOD, and SPH inverters, high-speed IGBT or SiC MOSFET switches chop ~400V–800V DC into pure grid-synchronized AC sinewaves. Dedicated isolated gate-driver ICs watch switch collector-emitter voltage continuously so short circuits never explode modules.

Non-Resettable Protection Trip: Whenever lightning transients, severe utility short circuits, or age-related thermal stress fault an IGBT gate driver (Error 413), safety protection freezes PWM switching immediately. While a single 10-minute cold reboot tests against rare static glitches, repeated Error 413 cleanly proves damaged hardware requiring unit RMA.

🔀 Hardware & Series Differences

Growatt MOD / MID / MAX Three-Phase
Error 413 (IGBT Drive Fault on 3-phase bridge or T-type NPC switches)

Often accompanied simultaneously by Error 409 or Error 120 following severe AC short circuits.

Growatt MIN / SPH Residential
H-bridge or bidirectional battery-buck IGBT driver desaturation failure

Hybrid models require testing reboot with battery breaker left OFF to isolate DC stage load.

🔍 Observable Symptoms

  • •Solid red LED with Error 413 appearing instantaneously when startup reaches boost/inverter bridge check.
  • •Zero solar export or hybrid backup operation.
  • •Occasionally preceded by sharp electrical pops or severe nearby thunderstorm lightning.

⚙️ Ranked Root Causes

Shorted or degraded IGBT/MOSFET power semiconductor switch inside inverter bridgeHigh

Thermal cycling or load surges break semiconductor junctions, tripping gate driver DESAT instantaneously.

Failed isolated +/-15V auxiliary gate-driver power supply transformer or optocouplerHigh

Missing isolated drive bias makes healthy IGBTs trigger open-gate fault feedback.

Dead short on AC output port or EPS backup load (on hybrid models) stressing output bridgeMedium

Direct home short circuits during backup failover overwhelm output switching limits.

Lightning surge traveling across unprotected long PV strings or AC feederMedium

High-voltage spikes puncture gate-oxide insulation permanently.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1AC ISOLATE
Turn Solar AC Breaker & EPS Backup Loads OFF

Isolate utility grid and any external hybrid emergency backup circuit first.

2DC / BATT OFF
Switch Battery & Exterior PV DC Rotary Switch OFF

Leave unit completely dead for 10 full minutes to discharge DC bus capacitors cleanly.

3CHECK / VERIFY
Attempt Only One Clean Reboot; Leave Isolated If Error 413 Remains

If Error 413 returns straightaway, turn AC & DC back OFF until technician arrives.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Run One Safe 10-Minute Shutdown & Check Burn Smells

Homeowner Safe

Before restarting once, sniff gently near the exterior vents for sharp scorched electronics odors—if smelled, skip rebooting and leave switches OFF.

✓ Expected ResultPrevents secondary damage if a semiconductor visibly failed after lightning.
→ If Fault PersistsTurn AC and PV DC OFF cleanly and schedule an authorized Growatt installer visit.
2

Unplug Non-Essential Loads If Using SPH EPS Port

Homeowner Safe

On hybrid backup models, switch off critical-load subpanel breakers before testing one cold restart so no downstream wiring fault trips output.

✓ Expected ResultSeparates downstream shorted house appliances from an internal inverter bridge failure.
→ If Fault PersistsError 413 continuing under zero load proves internal hardware failure.
3

Verify Array Voc, Isolation & AC/EPS Load Shorts Externally

Licensed Technician

Before installing any replacement unit, test PV array Voc/polarity and external AC/EPS circuit resistance cleanly to eliminate site shorts.

✓ Expected ResultConfirms external solar wiring and building circuits are fault-free prior to RMA swap.
→ If Fault PersistsRepair any pinched rooftop wiring or shorted backup load before installing replacement inverter.
4

Document Error 413 & Process Factory Warranty Swap

Licensed Technician

Capture serial plate photo, cold-boot fault confirmation, and AC/PV/EPS verification measurements for immediate Growatt replacement dispatch.

✓ Expected ResultManufacturer approves new replacement power unit under hardware warranty.
→ If Fault PersistsCommission replacement unit safely and verify clean SPDs on AC and DC panels.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error 413? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Calibrated True-RMS Multimeter
  • •Insulation Resistance Tester (Array Verify)
  • •Clamp Ammeter
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Growatt Error 413

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Can I repair Growatt Error 413 myself?

No. Error 413 flags serious internal high-voltage IGBT power-stage faults. Beyond performing at most one clean shutdown (assuming no scorched smell), only manufacturer unit/board replacement solves it.

What caused Error 413 during a thunderstorm?

Surge voltages entering along utility lines or unshielded rooftop PV runs exceed IGBT gate-oxide ratings. Adding Type II AC and DC surge arresters shields replacements effectively.

Does Error 413 void my Growatt warranty?

Normal component fatigue and drive faults are covered under Growatt's warranty. Only visible physical burn damage from an unmitigated direct lightning strike or over-voltage string design falls under insurance.

Related Growatt Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).