Fault Code P2High⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

Mitsubishi Ecodan Fault P2: Liquid Refrigerant Thermistor (TH2)

Affected Models: Mitsubishi Ecodan Split Hydroboxes & Cylinders (EHSC, EHST, ERSC, ERST with PUHZ-SW / SHW)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$150 - $340 USD
Warranty may cover parts
Diag / Fix Time
45 - 90 mins
Refrigerant Pipe Sensor Fault

⚡ Quick Engineering Answer

Mitsubishi Electric Ecodan • Fault Code P2

Mitsubishi Ecodan Fault Code P2 means the controller detected an open or short circuit on liquid refrigerant pipe thermistor TH2 inside the indoor hydrobox or cylinder. Because TH2 tracks phase change across the plate exchanger, heating halts until a technician inspects the plug, clears corrosion, or replaces the external TH2 probe.

Recovery Behavior:Compressor remains locked out until TH2 sensor continuity returns and controller is power-cycled.
SCHEMATIC // Mitsubishi Electric Ecodan Fault Code P2 — Air-to-Water Heat Pump Architecture
PERIMETER: SEALED ENCLOSURE
Mitsubishi Electric Ecodan Fault Code P2: Refrigerant Cycle & Pressure Valves System DiagramACR32 / R410AEXP / PRESSSEALED F-GAS BOUNDARYMains ACIsolator &Rectifier BusOutdoor UnitCompressor / IPMFan & Outdoor PCBRefrigerant LoopEEV / 63H / S1PHPipe NTC (TH2/J3/J6)Indoor HydroboxA1P PCB / EEPROMCoil NTC / BlowerHydronic Flow LoopPlate HX / StrainerPump / Flow / THWRadiators& DHW TankFlow LWT →← ReturnComms & ThermostatF1/F2 • S1-S3 • P1/P2FTC & RF LinkFAULT TARGET HIGHLIGHTEDFault Node
Highlighted Fault Node
Refrigerant Cycle & Pressure Valves
Signal / Power Path
EEV / LEV, High-Low Pressure Switch & Thermistors
Safety Access Line
Sealed Chassis — Liquid Refrigerant Pipe Thermistor (TH2)

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Indoor liquid refrigerant pipe thermistor TH2 measured an electrical open or short circuit.
Trigger Threshold
TH2 reads <-40°C (open) or >90–150°C (short) for >5 sec
Recovery Window
Manual reset after repairing TH2 sensor or harness
Subsystem Affected
Liquid Refrigerant Pipe Thermistor (TH2)
Warranty Outlook
OEM TH2 thermistor covered inside warranty window

How Mitsubishi Electric Ecodan Fault Code P2 Triggers

While water thermistors log under L5, Ecodan's P-series faults pinpoint refrigerant-side sensors attached to the indoor plate heat exchanger. Thermistor TH2 sits inside a small copper well strapped to the liquid refrigerant pipe exiting or feeding the indoor exchanger.

Accurate TH2 telemetry coordinates expansion valve control and safeguards exchanger plates during cold outdoor defrost reversals. Condensation creeping inside torn Armaflex pipe insulation frequently corrodes TH2's resin capsule, or vibration snaps fine leads at the PCB plug, locking the unit in P2.

🔀 Hardware & Series Differences

Split Ecodan Units (EHST / EHSC + PUHZ)
TH2 connects at indoor refrigerant liquid line into plate heat exchanger

Condensation during defrost wets unsealed copper wells rapidly.

PAC-IF Control Interface Boxes
Also maps P2 directly to Indoor Liquid Pipe Thermistor TH2

Check exact 10kΩ vs 50kΩ NTC thermistor chart per revision.

🔍 Observable Symptoms

  • •Controller stops with Fault P2 at power-up or mid-defrost.
  • •Compressor refuses space heating and DHW cylinder operation.
  • •Service Menu TH2 value displays dashes (---) or -40°C.
  • •Damp lagging around indoor refrigerant connections.

⚙️ Ranked Root Causes

Condensation moisture corroding TH2 inside copper sensor wellHigh

Torn pipe insulation traps defrost condensation inside downward pockets.

Loose, unseated, or oxidized plug on indoor hydrobox PCBHigh

Poor pin contact after servicing interrupts low-voltage sensing.

Pinched or vibration-chafed TH2 harness leadMedium

Line vibration slowly rubs thin sensor insulation bare.

Damaged ADC input channel on indoor interface PCBLow

Shorted wiring damages PCB pull-up electronics.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Inspect Running Information for TH2

Check front controller diagnostics to confirm anomalous -40°C reading.

2DISCHARGE / WAIT
Cycle Both Breakers Once

Turn OFF indoor and outdoor switches 60s, then power outdoor ON first and indoor second.

3SEQUENCE STEP
Enable Backup Immersion If Needed

Stop toggling breakers if P2 returns immediately and call an engineer.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Thermostat • Airflow • Filter • Isolator
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
240V / Pressurized R32
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
IPM Bridge • Compressor • Sealed Circuit
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Read Live TH2 Data on Front Panel

Homeowner Safe

Check Running Information on the front screen without opening panels to verify TH2 shows impossible values while THW water sensors look normal.

✓ Expected ResultCleanly identifies TH2 as the failed pipe sensor.
→ If Fault PersistsCheck whether external copper pipe lagging feels wet or torn.
2

Execute One Cold Power Cycle

Homeowner Safe

Isolate indoor and outdoor breakers for 60 seconds, then restore outdoor ON first and indoor ON second.

✓ Expected ResultRules out a rare boot initialization misread.
→ If Fault PersistsImmediate P2 return confirms a hardware sensor or harness break.
3

Measure TH2 Resistance Cold & Hot

Licensed Technician

Isolate power safely, remove cover, unplug TH2 connector from indoor board, and measure kΩ resistance against copper pipe temperature.

✓ Expected ResultOpen (OL) or short confirms broken sensor without touching refrigerant.
→ If Fault PersistsTest PCB socket with reference resistor if TH2 checks fine.
4

Fit New OEM TH2 & Seal Vapor Barrier

Licensed Technician

Clean copper pocket, fit OEM TH2 sensor with retaining clip and thermal grease, and reseal closed-cell pipe lagging tightly.

✓ Expected ResultLive TH2 reading tracks actual pipe temp and P2 clears.
→ If Fault PersistsRepair harness continuity or replace damaged interface PCB.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Fault Code P2? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your F-Gas / HVAC technician should bring:

  • •Digital Multimeter (kΩ range)
  • •OEM Mitsubishi TH2 Thermistor
  • •Closed-Cell Insulation Tape
⚠️
High Hazard AlertF-Gas / HVAC Specialist Required

Do Not Attempt Sealed Loop Repairs on Mitsubishi Electric Ecodan Fault Code P2

This fault involves pressurized refrigerant lines, compressor inverter boards, or internal hydronic controls. Under F-Gas, EPA Section 608, and OEM warranty rules, opening sealed refrigeration or pump chassis requires certified pros. Get competitive quotes from HVAC & heat pump specialists in your postal area:

✓ No obligation quotes✓ Pre-screened F-Gas / HVAC certified specialists✓ 100% Free dispatch

❓ Frequently Asked Questions

Does fixing Fault P2 require draining F-Gas refrigerant?

No. TH2 sits externally in a dry sealed copper pocket on the pipe wall, so technicians replace it without opening sealed refrigerant lines.

Is P2 caused by dirty central heating water filters?

No. P2 strictly flags an electrical open or short circuit on the TH2 refrigerant pipe sensor.

Can condensation cause Fault P2?

Yes. Defrost condensation trickling down poorly insulated cold lines enters unsealed pockets and corrodes TH2 leads.

Related Mitsubishi Electric Ecodan Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).