⚡ Certified Solar & Heat Pump Hardware Diagnostics • Verified Against 2026 Engineering Specs
VoltFaults
Air-to-Water Heat Pump15 Verified Codes• 1 DIY Safe (External)• 5 Auto-Recovering

Mitsubishi Electric Ecodan Error Codes & Fix Guides

Market-leading Japanese air-source and water-source residential heat pumps featuring Zubadan flash-injection technology. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.

Mitsubishi Electric Ecodan Hardware Signal Topology

Air-to-Water Heat Pump
R32 LINELWT/RWTOutdoor Inverter UnitCompressor • IPM • EEVFan & Pressure 63H/S1PHHydrobox / FTC UnitPlate HX • StrainerCirculator & Flow NTCHeating & DHWUFH / RadiatorsThermal LoadS1-S2-S3 Bus & PAR-WT50RWired Keypad / RF Receiver Telemetry

Mitsubishi Electric Ecodan Diagnostic Profile (15 Codes)

DIY Safe (External): 1 (7%)Pro Only: 14
Auto-Recovering: 5 (33%)Latched: 10
Severity Distribution
● Crit 7● High 6● Warn/Med 2
OEM Manual Coverage: 100%OEM Portal ↗
Showing 15 / 15
Fault Code L5
Pro OnlyHigh

Mitsubishi Ecodan Fault L5: Water Thermistor Open or Short

FTC control board measured an out-of-range voltage, unplugged harness, or short on a THW water thermistor.

Est. Cost: $140 - $320Fix Guide →
Fault Code L6
Pro OnlyCritical

Mitsubishi Ecodan Fault L6: Circulation Water Freeze Protection

Primary heating water temperature inside the plate heat exchanger dropped toward freezing due to stalled or restricted circulation.

Est. Cost: $160 - $420Fix Guide →
Fault Code L8
Pro OnlyHigh

Mitsubishi Ecodan Fault L8: Heating Error (No Water Temperature Rise)

FTC detected negligible water temperature gain between THW1 flow and THW2 return despite sustained heating demand.

Est. Cost: $180 - $650Fix Guide →
Fault Code L9
Pro OnlyHigh

Mitsubishi Ecodan Fault L9: Low Primary Circuit Water Flow

Inline flow sensor measured heating loop circulation below safe minimum volume across the plate heat exchanger.

Est. Cost: $120 - $340Fix Guide →
Fault Code U1
Pro OnlyCritical

Mitsubishi Ecodan Fault U1: High Pressure Switch Tripped (63H)

Refrigerant discharge pressure exceeded high-pressure safety switch 63H limits, stopping the outdoor compressor.

Est. Cost: $150 - $480Fix Guide →
Fault Code U2
Pro OnlyCritical

Mitsubishi Ecodan Fault U2: Abnormal Compressor Discharge Temp

Discharge thermistor TH4 detected overheating compressor outlet gas above safe thermal limits.

Est. Cost: $220 - $680Fix Guide →
Fault Code U5
Pro OnlyCritical

Mitsubishi Ecodan Fault U5: Inverter Heat Sink Overheat Protection

Outdoor inverter heatsink thermistor (TH8) exceeded safe operating heat, tripping power-module thermal protection.

Est. Cost: $160 - $580Fix Guide →
Fault Code P2
Pro OnlyHigh

Mitsubishi Ecodan Fault P2: Liquid Refrigerant Thermistor (TH2)

Indoor liquid refrigerant pipe thermistor TH2 measured an electrical open or short circuit.

Est. Cost: $150 - $340Fix Guide →
Fault Code P8
Pro OnlyHigh

Mitsubishi Ecodan Fault P8: Plate Heat Exchanger Temp / Pipe Error

Refrigerant pipe temperature failed expected change across the plate heat exchanger during active heating or defrost.

Est. Cost: $160 - $540Fix Guide →
Fault Code E0
Pro OnlyMedium

Mitsubishi Ecodan Fault E0: Wired Remote Controller Transmission Error

Wired remote controller transmission failed across the two-wire communication link to the indoor FTC board.

Est. Cost: $120 - $280Fix Guide →
Fault Code E1
Pro OnlyCritical

Mitsubishi Ecodan Fault E1: Controller Board / Main PCB Fault

Internal remote controller PCB or FTC logic board failed electronic self-diagnostics or reception loopbacks.

Est. Cost: $280 - $750Fix Guide →
Fault Code E6
Pro OnlyCritical

Mitsubishi Ecodan Fault E6: Indoor / Outdoor Communication Error

Indoor unit failed to receive valid data packets from the outdoor unit across the S1-S2-S3 communication link.

Est. Cost: $120 - $450Fix Guide →
Fault Code E9
Pro OnlyCritical

Mitsubishi Ecodan Fault E9: Indoor / Outdoor Transmission Failure

Outdoor unit failed to transmit valid replies back to indoor FTC across S1-S2-S3 interconnecting wiring.

Est. Cost: $120 - $450Fix Guide →
Fault Code J0
Pro OnlyHigh

Mitsubishi Ecodan Fault J0: FTC & Wireless Receiver Comm Fault

FTC main control board stopped receiving wired communication frames from the wireless receiver box (PAR-WR51R) for over 1 minute.

Est. Cost: $140 - $340Fix Guide →
Fault Code J5
DIY SafeMedium

Mitsubishi Ecodan Fault J5: Wireless Thermostat Communication Fault

Wireless receiver lost RF radio link from the battery-powered wireless thermostat assigned to zone address 5.

Est. Cost: $0 - $140Fix Guide →
Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians