Mitsubishi Electric Ecodan Error Codes & Fix Guides
Market-leading Japanese air-source and water-source residential heat pumps featuring Zubadan flash-injection technology. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Mitsubishi Electric Ecodan Hardware Signal Topology
Mitsubishi Electric Ecodan Diagnostic Profile (15 Codes)
Mitsubishi Ecodan Fault L5: Water Thermistor Open or Short
FTC control board measured an out-of-range voltage, unplugged harness, or short on a THW water thermistor.
Mitsubishi Ecodan Fault L6: Circulation Water Freeze Protection
Primary heating water temperature inside the plate heat exchanger dropped toward freezing due to stalled or restricted circulation.
Mitsubishi Ecodan Fault L8: Heating Error (No Water Temperature Rise)
FTC detected negligible water temperature gain between THW1 flow and THW2 return despite sustained heating demand.
Mitsubishi Ecodan Fault L9: Low Primary Circuit Water Flow
Inline flow sensor measured heating loop circulation below safe minimum volume across the plate heat exchanger.
Mitsubishi Ecodan Fault U1: High Pressure Switch Tripped (63H)
Refrigerant discharge pressure exceeded high-pressure safety switch 63H limits, stopping the outdoor compressor.
Mitsubishi Ecodan Fault U2: Abnormal Compressor Discharge Temp
Discharge thermistor TH4 detected overheating compressor outlet gas above safe thermal limits.
Mitsubishi Ecodan Fault U5: Inverter Heat Sink Overheat Protection
Outdoor inverter heatsink thermistor (TH8) exceeded safe operating heat, tripping power-module thermal protection.
Mitsubishi Ecodan Fault P2: Liquid Refrigerant Thermistor (TH2)
Indoor liquid refrigerant pipe thermistor TH2 measured an electrical open or short circuit.
Mitsubishi Ecodan Fault P8: Plate Heat Exchanger Temp / Pipe Error
Refrigerant pipe temperature failed expected change across the plate heat exchanger during active heating or defrost.
Mitsubishi Ecodan Fault E0: Wired Remote Controller Transmission Error
Wired remote controller transmission failed across the two-wire communication link to the indoor FTC board.
Mitsubishi Ecodan Fault E1: Controller Board / Main PCB Fault
Internal remote controller PCB or FTC logic board failed electronic self-diagnostics or reception loopbacks.
Mitsubishi Ecodan Fault E6: Indoor / Outdoor Communication Error
Indoor unit failed to receive valid data packets from the outdoor unit across the S1-S2-S3 communication link.
Mitsubishi Ecodan Fault E9: Indoor / Outdoor Transmission Failure
Outdoor unit failed to transmit valid replies back to indoor FTC across S1-S2-S3 interconnecting wiring.
Mitsubishi Ecodan Fault J0: FTC & Wireless Receiver Comm Fault
FTC main control board stopped receiving wired communication frames from the wireless receiver box (PAR-WR51R) for over 1 minute.
Mitsubishi Ecodan Fault J5: Wireless Thermostat Communication Fault
Wireless receiver lost RF radio link from the battery-powered wireless thermostat assigned to zone address 5.
No fault codes match the active filter combination.