VoltFaults
Error F33High⚡ Pro Only (No Cover Open)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Deye Error F33: Temperature Sensor Fault / AC Overcurrent (Series Diff)

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SG05LP1 (Sensor) & SUN-G03 String Inverters (AC Overcurrent)

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$140 - $380 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
Internal Thermal Sensing / Series Specific

⚡ Quick Engineering Answer

Deye • Error F33

On Deye low-voltage hybrid inverters (SG04LP1/LP3), Error F33 indicates an Internal Temperature Sensor Fault (disconnected or out-of-range NTC probe inside the inverter)—whereas on SUN-G03 three-phase grid string units, F33 denotes AC Overcurrent Fault. Run one external cooldown restart safely; checking internal thermal plugs requires a qualified technician.

Recovery Behavior:Hybrid SG04 temperature-probe noise may clear after cooldown reboot; persistent F33 needs internal NTC/connector repair or SUN-G03 AC load audit.
SCHEMATIC // Deye Error F33 — Hybrid PV + Storage Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Deye Error F33: Heatsink Thermal & Fan Airflow Path System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
Heatsink Thermal & Fan Airflow Path
Signal / Power Path
Rear Fin Channels, Blower & Internal NTC Sensors
Safety Access Line
Sealed Chassis — Internal NTC Thermal Harness (Hybrid) / AC Output Stage (String)

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Internal NTC temperature sensor reading out of bounds on Deye hybrids, or AC overcurrent trip on grid-tied string models.
Trigger Threshold
Hybrid: NTC thermistor outside valid -25°C to +125°C ADC window; String: AC current spike > limit
Recovery Window
Manual 5-minute shutdown test; open thermal probe latches until plugged back in or replaced
Subsystem Affected
Internal NTC Thermal Harness (Hybrid) / AC Output Stage (String)
Warranty Outlook
Internal thermal thermistor defects covered under Deye 5/10-year hardware warranty

How Deye Error F33 Triggers

Because Deye distributes distinct firmware bases across its hybrid storage range versus commercial three-phase string inverters, Error F33 carries two completely separate official meanings depending on model family. On residential and commercial hybrids (SUN-SG04LP1 / LP3 / SG05LP1), F33 signals an out-of-range reading (open circuit -40°C or short circuit >150°C) on an internal heatsink, inductor, or ambient temperature thermistor.

On three-phase grid-tied string models (SUN-G03), however, Error F33 corresponds instead to AC_OverCurr_Fault. Always match the LCD descriptive text beneath F33: if temperature telemetry reads unrealistic negative values in Solarman, internal NTC probe connectors need inspection; if running SUN-G03 under full midday export, check AC output wire torque and grid swells.

🔀 Hardware & Series Differences

Deye Hybrid Inverters (SG04LP1 / LP3 / SG05LP1)
Internal Temperature Sensor Fault (NTC probe open/shorted on heatsink/transformer)

Inspect DC/AC heatsink temperatures inside LCD info screen for abnormal readings like -30°C or 180°C.

Three-Phase Grid-Tied String (SUN-G03)
AC Overcurrent Fault (AC_OverCurr_Fault)

Verify L1/L2/L3 AC breaker ratings, grid terminal torque, and severe voltage sag surges.

🔍 Observable Symptoms

  • •Touchscreen latches Error F33 cleanly at cool startup or after transport vibration.
  • •Solarman/LCD temperature diagnostics display nonsensical values (-40°C or 200°C) on hybrids.
  • •System cuts off generation even inside an air-conditioned utility room.
  • •String SUN-G03 units throw F33 mainly during unstable utility switching spikes.

⚙️ Ranked Root Causes

Unseated or vibration-loosened internal NTC thermal probe plug on main PCB (Hybrids)High

Shipping bumps or fan vibration back out small white 2-pin thermistor headers inside chassis.

Degraded internal NTC thermistor capsule drifting open/short (Hybrids)Medium

Repeated heatsink thermal expansion fractures thin internal probe wires.

External AC grid voltage instability causing output current surges (SUN-G03 String)Medium

Grid voltage collapse forces current spike while string inverter pushes full solar watts.

Failed motherboard ADC temperature sensing stageLow

Moisture corrosion or power surge damages the temperature input channel on DSP.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Inspect Live Heatsink / AC Temps on Front Display

Check LCD Device Info screen for DC_Temp and AC_Temp readings before restarting.

2DC / BATT OFF
Switch Off PV, Battery & AC Breakers (5 Mins)

Allow electronics to cool completely and capacitors to bleed dark.

3DISCHARGE / WAIT
Restart & Record Immediate Fault Behavior

If F33 triggers cleanly with zero load and cool room air, schedule internal probe check.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Read Live AC/DC Heat Sink Temps in Solarman / LCD Menu

Homeowner Safe

Open the inverter touch panel Device Info or Solarman temperature telemetry (keeping covers closed) and note DC/IGBT/Internal radiator temperature numbers.

✓ Expected ResultImpossible values such as -40°C, 0°C, or >150°C prove an open/short NTC sensor on hybrids cleanly.
→ If Fault PersistsPhotograph the screen info page and serial sticker for Deye support.
2

Execute One Safe 5-Minute External Cooldown Reboot

Homeowner Safe

Turn OFF external PV, battery, and AC grid switches for 5 full minutes, confirm unit fans aren't externally plugged with dust, then switch back ON.

✓ Expected ResultClears occasional ADC brownout misreads or brief string AC grid spikes.
→ If Fault PersistsConsistent return on cold startup signals unseated thermistor connector or failed probe.
3

Inspect Internal NTC Plugs & Test Probe Resistance (Hybrids)

Licensed Technician

Isolate AC/DC/Battery and discharge bus capacitors safely below 50V, inspect 2-pin NTC sensor headers along heatsink and main PCB for loose crimp pins, and measure kΩ thermistor resistance vs temperature.

✓ Expected ResultReseating backed-out JST thermistor connectors often resolves shipping-related F33 without parts.
→ If Fault PersistsCheck AC grid stability and terminal tightness if servicing a SUN-G03 string model.
4

Replace Faulted NTC Harness or Service Power Board

Licensed Technician

Install genuine replacement NTC sensor probe with fresh thermal paste against heatsink, or submit Deye warranty claim for main DSP PCB if good probes read incorrectly.

✓ Expected ResultLive heat sink telemetry reads accurate ambient-to-load curve and F33 clears permanently.
→ If Fault PersistsProcess warranty unit replacement via Deye service portal.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F33? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •True-RMS Multimeter (Ω Scale & DC Voltage Check)
  • •OEM Deye NTC Thermal Sensor & Thermal Grease
  • •Insulated Screwdriver Set
⚠️
High Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Deye Error F33

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Does Deye Error F33 mean Backup Load Short Circuit?

No—that confusion comes from older mixed charts. Official Deye SG04 hybrid manuals define F33 as an internal Temperature Sensor Fault (backup load overcurrent/overload sits at F34 and F18).

Can cooling air from a standing fan clear Error F33?

Usually no—unlike real heat warnings (F64), F33 on hybrids means a broken or unplugged temperature probe reading falsely extreme numbers regardless of airflow.

Why does my SUN-G03 string manual list F33 as AC Overcurrent?

Deye's pure on-grid string series shares F-number IDs differently from hybrid storage lines; always confirm whether your model uses the SG04 hybrid or SUN-G03 string fault table.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026