⚡ Certified Solar & Heat Pump Hardware Diagnostics • Verified Against 2026 Engineering Specs
VoltFaults
Error F18Critical⚡ Pro Only (No Cover Open)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Deye Error F18: Hardware AC Overcurrent Fault

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SUN-SG05LP1 & SUN-G03 Series

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$140 - $520 USD
Warranty may cover parts
Diag / Fix Time
45 - 120 mins
AC Output & Backup Overcurrent

⚡ Quick Engineering Answer

Deye • Error F18

Deye Error F18 indicates a fast hardware-level AC overcurrent trip (HW AC_OverCurr_Fault) on the inverter output or Backup Load port—triggered by excessive household surge appliances, dead AC short circuits, or failed current sensors/IGBTs. Safely turn off heavy backup appliances and sub-breakers to test unloaded reboot; wiring and board repairs require an electrician.

Recovery Behavior:Auto-retries briefly on transient load surge; hard short circuits or persistent AC overcurrent latch shutdown requiring load disconnect and restart.
SCHEMATIC // Deye Error F18 — Hybrid PV + Storage Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Deye Error F18: AC Protection Relays, Breaker & Grid System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
Sealed Chassis — IGBT AC Bridge, Hardware Overcurrent Comparator & Backup Port

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Hardware protection circuit detected sudden excessive AC output or grid port current past transistor ratings.
Trigger Threshold
Hardware AC current comparator tripped (> ~1.8x–2.5x rated peak output current)
Recovery Window
May auto-retry once; repeated trips lock out requiring breaker isolation + manual restart
Subsystem Affected
IGBT AC Bridge, Hardware Overcurrent Comparator & Backup Port
Warranty Outlook
Internal board/IGBT faults covered within warranty; external house short circuits excluded

How Deye Error F18 Triggers

Whereas software overload protections react over seconds, Deye Error F18 fires within microseconds via dedicated analog hardware comparators monitoring AC inverter legs. Its job is saving internal IGBT bridge transistors from exploding when confronted by downstream AC short circuits, grid fault transients, or huge off-grid compressor locked-rotor startup spikes.

In residential hybrid installations (SUN-5K/8K/12K-SG04LP1/LP3), F18 surfaces most frequently during off-grid power outages when heavy well pumps, split air conditioners, or hot water elements exceed the Backup LOAD port surge limit—or when an appliance shorts live-to-neutral. On units faulting repeatedly even unloaded with Grid/Backup breakers disconnected, suspect loose internal AC CT harnesses or blown IGBT gates.

🔀 Hardware & Series Differences

Deye Hybrid LV (SG04LP1 / LP3 — Off-Grid Backup Active)
Instantaneous AC Backup port surge or downstream appliance short-circuit

Check kW/surge draw on Backup LOAD panel (keep inductive motors within 1.5x–2x 10s surge window).

Grid-Tied / Unloaded Boot Lockout
Internal AC current sensor disconnect or damaged IGBT output driver stage

Immediate F18 with AC Grid + Backup Load breakers physically disconnected confirms internal hardware repair.

🔍 Observable Symptoms

  • •Backup LOAD outlets drop dark immediately during blackout startup of large motors/pumps.
  • •Touchscreen flashes Error F18 accompanied by loud relay click.
  • •May coincide with F34 AC overcurrent alarms on heavy load transitions.
  • •Repeats instantaneously on boot if output IGBT shorted.

⚙️ Ranked Root Causes

Downstream AC short circuit or heavy reactive startup surge on Backup portHigh

Water pumps, compressors, or shorted wiring exceed instantaneous peak AC output amps.

Severe utility grid line disturbance or sudden brownout switching surgeMedium

Step utility voltage drops force reactive surge currents across tied grid relays.

Loose internal AC current transformer (CT) connector inside inverterLow

Open/floating hardware sense harness sends false peak spikes to comparator.

Shorted internal IGBT module or gate drive failureLow

Internal power transistor failure draws instantaneous hardware overcurrent every startup.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1SEQUENCE STEP
Switch Off Heavy Appliances & Backup Load Sub-Breakers

Turn off AC pumps, heaters, and backup panel breakers completely before testing reboot.

2DISCHARGE / WAIT
Power Down External PV, Battery & AC Isolators (3 Mins)

Allow internal DC bus capacitors to drain completely until screen turns black.

3RESTORE & BOOT
Boot Unloaded First, Then Restore Breakers One by One

If F18 trips while completely unloaded, power off permanently and call service.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Disconnect Backup Appliances & Sub-Breakers for Load Test

Homeowner Safe

Switch off heavy backup circuit breakers (air conditioning, well pumps, water heaters) in your home sub-panel, turn external inverter switches OFF for 3 minutes, then restart unloaded.

✓ Expected ResultConfirms whether an overloaded or shorted household circuit caused F18.
→ If Fault PersistsTurn Backup sub-breakers back ON one circuit at a time to catch the exact tripping appliance.
2

Check Solarman Load Graphs Right Before Fault

Homeowner Safe

Inspect Load Power (kW) on individual L1/L2/L3 phases in Solarman right before F18 logged to spot phase overloads on three-phase SG04LP3 units.

✓ Expected ResultPinpoints single-phase imbalance exceeding per-phase kW limits.
→ If Fault PersistsImmediate F18 with ZERO load breakers connected indicates hardware fault requiring service.
3

Test Output AC Wiring Megger & Isolate All Field Cables

Licensed Technician

De-energize inverter safely, check L-N-PE resistance on field Backup and Grid wiring for shorts, disconnect external AC wires completely, and run standalone battery-only self-test.

✓ Expected ResultDefinitively isolates external household short circuits from internal inverter damage.
→ If Fault PersistsInspect internal AC current transformer (CT) plug seating and hardware comparator sensing board.
4

Rebalance Phase Loads / Install Soft-Starter or Replace Power Board

Licensed Technician

Rebalance high-draw backup loads across three phases or fit soft-starters to deep-well pumps; replace faulted IGBT power board under warranty if unloaded F18 locks.

✓ Expected ResultClean inverter output sustains rated loads without hardware overcurrent shutdown.
→ If Fault PersistsPerform Deye warranty RMA replacement.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F18? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •AC True-RMS Clamp Meter (Inrush Mode)
  • •Insulation Continuity Tester
  • •Load Phase Balancing Diagram
⚠️
Critical Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Deye Error F18

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

What is the difference between Deye F18 and F34?

Both monitor AC output current: F18 is an instant hardware comparator trip triggered by extreme short circuits or sharp surges, while F34 tracks slower continuous/software AC overcurrent.

Can running a heavy well pump or microwave during a power outage cause F18?

Yes! On 120/240V or single-phase hybrids, high startup inrush current on an AC motor exceeding inverter peak rating triggers instantaneous F18 hardware cutoff.

If F18 pops up with all house breakers turned OFF, is the inverter broken?

Most likely yes—either an internal current-sense wire loosened or an internal IGBT output module failed and requires Deye service/RMA.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).

Emergency Installer Dispatch Network

Can't Resolve Your Hardware Fault?

High-voltage DC solar systems and heat pumps require certified technicians. Connect with NABCEP-certified solar electricians and F-Gas certified heat pump specialists in your region.

Free quotes • No commitment • Local certified technicians