Deye Error F34: AC Overcurrent / Backup Overload Fault
Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SG05LP1 & Select SUN-G03 String Models
⚡ Quick Engineering Answer
Deye • Error F34On Deye hybrid inverters (SG04LP1/LP3), Error F34 (AC_OverCurr_Fault / AC Overload) means power demanded on the Backup LOAD or AC port exceeded inverter continuous capacity—NOT Input Phase Sequence! (Note on select SUN-G03 string models, F34 maps to internal communication timeout). Safely switch off heavy appliances on your Backup sub-panel first.
📊 Technical Specification & Trigger Matrix
- Official Manual Definition
- AC output load on the Backup/UPS port exceeded continuous current ratings (or internal comms timeout on select string models).
- Trigger Threshold
- AC output current > 105%–125% continuous phase rating beyond allowed transient window
- Recovery Window
- Auto-restarts in ~30–60s once Backup load decreases; latches after repeat trips
- Subsystem Affected
- Backup LOAD Output Bridge & Per-Phase Current Limiter
- Warranty Outlook
- Normal overload protection (0% hardware failure); phase rebalancing is electrician scope
How Deye Error F34 Triggers
During normal grid-connected periods, external utility transfer switches carry substantial household wattage seamlessly—yet the moment utility grid collapses or inverter bypass limits activate, all connected appliances on the LOAD (Backup) port draw power strictly through the inverter's electronic current ceiling (Error F34).
In three-phase setups (SUN-SG04LP3), watch out for single-phase concentration: plugging a 5kW kettle, oven, and dryer onto L1 inside a 12kW three-phase inverter still overloads that single 4kW phase leg and throws F34 even when total system draw reads only 40%! Start by shedding non-essential backup loads externally before requesting an electrician to rebalance phases or install load-shedding smart contactors.
🔀 Hardware & Series Differences
Verify both total inverter kW AND per-phase continuous amps on three-phase LP3 models.
Requires 5-minute full power reset and firmware audit if no backup loads are attached.
🔍 Observable Symptoms
- •Backup house circuits flicker OFF mid-blackout right after turning on a kettle, microwave, or heater.
- •Touchscreen shows Error F34 and re-attempts output 30 seconds later.
- •Solarman Load power graph spikes near phase limit right before outage.
- •Single-phase breakers on L1 overload while L2 and L3 sit barely utilized.
⚙️ Ranked Root Causes
Electric water heaters, ovens, and HVAC compressors exceed backup inverter kW budget.
3-phase hybrids generally cap each individual phase to roughly one-third (or half on 100% unbalance support) of total rating.
High-resistance appliance fault or leaky heating element draws extra steady current.
Serial glitch inside grid-only units resets after clean 5-minute DC+AC shutdown.
🔄 Safe Shutdown & Reset Sequence Flow
Follow strict step order left-to-rightUnplug kettles, air fryers, space heaters, and turn off HVAC/boiler breakers.
Wait 60 seconds or cycle PV/Battery/AC switches if F34 latched after multiple retries.
Bring essential lighting and Wi-Fi breakers back online while avoiding stacked high-wattage draws.
High-Voltage / Refrigerant Safety Boundary: Pro Service Split
Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.
🔧 Interactive Step-by-Step Diagnostic Checklist
Shed Non-Essential High-Wattage Loads on Backup Panel
Turn off electric geysers, kitchen ovens, tumble dryers, or heat pumps fed from your solar Backup LOAD sub-panel, wait 60 seconds, and verify normal power returns.
Check Per-Phase Load Wattage in Solarman App
Open live inverter telemetry in Solarman or the front LCD home diagram to view L1, L2, and L3 Load kW right before F34 occurred.
Rebalance 3-Phase Circuits & Audit Essential vs Non-Essential Wiring
Redistribute heavy Backup outlets evenly across L1/L2/L3 (or shift heavy geysers/EV chargers back onto the Grid-Only non-backup side / SMART Load port configured for grid-on shed).
Verify Pass-Through Relay Limits & Internal AC Current CTs
Confirm grid pass-through current settings match breaker size, verify internal AC CT calibration against True-RMS clamp readings, and update SUN-G03 comms firmware if string unit shows F34 unloaded.
📋 Ready-to-Send Technician Fault Brief
Completed safe checks without clearing Error F34? Copy this structured engineering summary for your installer or OEM RMA ticket.
🧰 Field Reference: What Your Technician Will Inspect
For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:
- •AC True-RMS Clamp Meter (Per-Phase Load Audit)
- •Backup Distribution Panel Load Schedule
- •Smart Load Contactor / Shedding Schematic
Don't Risk High-Voltage Shock with Deye Error F34
This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:
❓ Frequently Asked Questions
Does Deye Error F34 mean AC Input Phase Sequence Error?
No—that confusion sits on copied internet blogs. On Deye SG04LP1/LP3 hybrid units, F34 strictly signals AC Overcurrent / Backup Overload (whereas phase sequence errors map to grid-string codes or F22/F42 depending on firmware).
Why does my 12kW three-phase Deye trip F34 when my house uses only 4.5kW?
Because a 12kW three-phase hybrid typically limits any single phase (L1, L2, or L3) to ~4kW–6kW continuous! Putting too many heavy plugs onto L1 trips phase overcurrent early.
How can I prevent F34 automatically during blackouts?
Have your electrician move ovens, hot-water heaters, and pool pumps onto the non-backed-up Grid panel (or Deye's programmable Smart Load port, which drops them automatically when grid fails).
Related Deye Fault Codes
Hardware protection circuit detected sudden excessive AC output or grid port current past transistor ratings.
Fast analog hardware protection tripped due to excessive DC current surge on the PV or battery converter stage.
Internal NTC temperature sensor reading out of bounds on Deye hybrids, or AC overcurrent trip on grid-tied string models.
Inverted positive and negative DC polarity detected across one or more PV MPPT string inputs.