Fault UACritical⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

Daikin Altherma Fault UA: Indoor/Outdoor Combination Mismatch

Affected Models: Daikin Altherma LT/HT (ERGA, ERLQ, EHVH, EHBH) & Daikin Split/VRV

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$140 - $420 USD
Warranty may cover parts
Diag / Fix Time
30 - 90 mins
Unit Capacity & Model Pairing

⚡ Quick Engineering Answer

Daikin Altherma • Fault UA

Daikin Fault UA (UA-00 / Field Setting Combination Error) alerts when an Indoor Hydrobox (or Split) disagrees in capacity/refrigerant type (R32 vs R410A) with the Outdoor Unit—most notoriously right after installing a spare replacement A1P Indoor/Outdoor PCB without transferring the little green/white Capacity Identification Adapter (EEPROM) or setting DIP switches!

Recovery Behavior:Remains locked until replacement PCB DIP/capacity adapters match exact unit models OR incompatible indoor/outdoor hardware pairings are resolved by a technician.
SCHEMATIC // Daikin Altherma Fault UA — Air-to-Water Heat Pump Architecture
PERIMETER: SEALED ENCLOSURE
Daikin Altherma Fault UA: Indoor–Outdoor Bus & Room Controller System DiagramACR32 / R410AEXP / PRESSSEALED F-GAS BOUNDARYMains ACIsolator &Rectifier BusOutdoor UnitCompressor / IPMFan & Outdoor PCBRefrigerant LoopEEV / 63H / S1PHPipe NTC (TH2/J3/J6)Indoor HydroboxA1P PCB / EEPROMCoil NTC / BlowerHydronic Flow LoopPlate HX / StrainerPump / Flow / THWRadiators& DHW TankFlow LWT →← ReturnComms & ThermostatF1/F2 • S1-S3 • P1/P2FTC & RF LinkFAULT TARGET HIGHLIGHTEDFault Node
Highlighted Fault Node
Indoor–Outdoor Bus & Room Controller
Signal / Power Path
F1/F2 or S1-S3 Data Line & P1/P2 / RF Link
Safety Access Line
Sealed Chassis — Unit Combination Firmware Table, Capacity Plug Adapter & PCB DIP Settings

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Indoor and outdoor unit series, capacity ratings, or spare PCB jumper configurations are mismatched.
Trigger Threshold
Cross-unit handshake fails refrigerant generation, kW capacity limit, or installed PCB jumper check
Recovery Window
Locked fault until matched hardware pairing or correct capacity jumper/setting installs
Subsystem Affected
Unit Combination Firmware Table, Capacity Plug Adapter & PCB DIP Settings
Warranty Outlook
Blank spare-part capacity omission belongs to field service setup; physical model incompatibility requires installer equipment exchange

How Daikin Altherma Fault UA Triggers

Upon initial power-on, every Daikin Altherma (ERGA/EHVH or ERLQ/EHBH) and VRV setup queries model series, kW capacity index, and refrigerant type (R32 vs R410A) across indoor-outdoor communication buses (U4).

The Replacement PCB Adapter Trap (UA): While physical installation pairing errors (like wiring an R32 EHVH Hydrobox outdoors onto an older R410A ERLQ condenser!) lock Fault UA immediately on new installs, 70% of service-call Fault UA cases erupt moments after swapping a fresh blank spare PCB where technicians overlooked swapping the old board's tiny Model Capacity Plug / Setting Switch onto the new spare board!

🔀 Hardware & Series Differences

Post-Service Spare PCB Swap (E1 / A1 Repair Followed by UA)
Generic blank replacement A1P PCB lacks site-specific Model Capacity Identification jumper/EEPROM setting

Verify spare board installation sheet—move original green/white capacity plug from old PCB (if undamaged) or set installer capacity code!

New Commissioning / Multi-Split Mismatch (UA-00 / UF)
Connected indoor total kW capacity exceeds rated outdoor condenser range (or mixed R32 indoor + R410A outdoor)

Compare Daikin Official Engineering Combination Tables across exact outdoor/indoor chassis SKUs.

🔍 Observable Symptoms

  • •System turns on immediately following brand-new installation OR straight after a technician replaced a PCB, locking onto Fault UA.
  • •Zero heating/cooling startup; outdoor compressor never engages.
  • •May swap back cleanly once missing capacity jumper or address reset completes.

⚙️ Ranked Root Causes

Forgot transferring existing Model Capacity Adapter PCB / Jumper or DIP configuration onto a brand-new spare boardHigh

Daikin sells shared universal spare boards shipped needing unit-specific capacity adapters clipped in.

Incompatible R32 vs R410A or wrong Capacity Class indoor Hydrobox connected to outdoor unit on new buildMedium

Warehouse shipping mix-ups pair e.g. 11–16kW units onto 4–8kW boxes cleanly triggering UA!

Multi-split / VRV system wiring exceeded max permissible indoor units (e.g. >130% combined load ratio)Medium

Adding one extra room indoor head onto a maxed-out condenser trips UA immediately.

Loose indoor/outdoor capacity ID EEPROM plug or mis-addressed branch port (low)Low

Vibration slightly lifts small modular PCB capacity jumper off header pins.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Both Indoor & Outdoor Model Stickers Side-by-Side

Verify matching refrigerant types (R32 vs R410A) and kW capacity series (4–8kW vs 11–16kW).

2DISCHARGE / WAIT
Try One 5-Minute Power Reset If Replacing Boards Only

Note that hardware mismatches (UA) never auto-fix on resets alone—contact installer/technician promptly.

3SEQUENCE STEP
Ask Recent Repair Technician About Old PCB Capacity Adapter Plug

Hold onto replaced failed circuit boards briefly until successful post-swap run finishes!

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Thermostat • Airflow • Filter • Isolator
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
240V / Pressurized R32
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
IPM Bridge • Compressor • Sealed Circuit
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Verify Both Indoor & Outdoor Rating Plates Match Contract

Homeowner Safe

Compare the white rating labels (Model SKU & Refrigerant R32/R410A) on your outdoor unit vs indoor unit cleanly—especially on brand-new installations.

✓ Expected ResultCatches warehouse shipping mix-ups (e.g. R32 Hydrobox matched to R410A outdoor condenser) immediately.
→ If Fault PersistsRecall if a repair technician just fitted a replacement PCB (the top trigger for sudden UA on older sites).
2

Keep Old Replaced PCB Safe Until Installer Verifies Settings

Homeowner Safe

If Fault UA appeared hours after board repair, ask your engineer immediately not to throw away the old board until capacity plugs/jumper codes are checked.

✓ Expected ResultSpares extra week-long factory part delays when a tiny plug-in ID adapter needs moving cleanly.
→ If Fault PersistsContact authorized Daikin installer/service engineer carrying Daikin Engineering Combination tables.
3

Check Spare Board Installation Sheet For Capacity Adapter & DIP Switches

Licensed Technician

Isolate mains safely (>10 min <10V DC verify outdoors), check universal spare PCB instructions strictly—confirming exact installed Capacity ID Plug (green/white/blue header) OR BS/DS DIP switches / Auto-Address Reset.

✓ Expected ResultTransferring the correct capacity jumper or applying model setting resolves post-repair UA instantaneously.
→ If Fault PersistsOn multi-split / VRV sites (UA vs U9), verify total connected indoor capacity index sits strictly within Daikin Combination Rules.
4

Trigger Full Address Reset / Re-Verify Refrigerant Generation Compatibility

Licensed Technician

Run outdoor board BS1/BS2/BS3 address reset (per VRV/Altherma service guide) after confirming matching R32/R410A generation hardware cleanly, then cycle power.

✓ Expected ResultIndoor/outdoor handshake succeeds cleanly (Fault UA vanishes completely).
→ If Fault PersistsSwap mismatched equipment module if non-compatible series were installed physically.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Fault UA? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your F-Gas / HVAC technician should bring:

  • •Daikin Model Combination Engineering Table
  • •OEM Spare PCB Capacity ID Plugs
  • •Daikin Service Manual (`DIP / BS Switch Sheet`)
⚠️
Critical Hazard AlertF-Gas / HVAC Specialist Required

Do Not Attempt Sealed Loop Repairs on Daikin Altherma Fault UA

This fault involves pressurized refrigerant lines, compressor inverter boards, or internal hydronic controls. Under F-Gas, EPA Section 608, and OEM warranty rules, opening sealed refrigeration or pump chassis requires certified pros. Get competitive quotes from HVAC & heat pump specialists in your postal area:

✓ No obligation quotes✓ Pre-screened F-Gas / HVAC certified specialists✓ 100% Free dispatch

❓ Frequently Asked Questions

Why did Daikin Fault UA show up right after a technician changed my main PCB?

Daikin stocks single shared replacement PCBs serving multiple kW capacities—each new PCB ships requiring either a tiny colored Model Capacity Adapter plug transferred cleanly from the old board or matching DIP switches configured (missing that step throws UA instantly).

Can an R32 Daikin Altherma Hydrobox talk to an R410A outdoor unit?

Never—they run different working pressures, sensors, and communication handshakes. Pairing mismatched series throws Fault UA immediately to block startup damage.

Will resetting the heat pump breaker clear Daikin Fault UA?

If an engineer just finished altering DIP switches (power-cycle required to latch new jumper), one power cycle applies them cleanly—otherwise resets alone cannot fix hardware or adapter mismatches.

Related Daikin Altherma Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).