Air-to-Water Heat Pump24 Verified Codes• 0 DIY Safe (External)• 11 Auto-Recovering

Daikin Altherma Error Codes & Fix Guides

Europe's leading domestic heating and heat pump systems. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.

Daikin Altherma Hardware Signal Topology

Air-to-Water Heat Pump
R32 LINELWT/RWTOutdoor Inverter UnitCompressor • IPM • EEVFan & Pressure 63H/S1PHAltherma HydroboxPlate HX • StrainerCirculator & Flow NTCHeating & DHWUFH / RadiatorsThermal LoadF1/F2 • P1/P2 Controller BusWired Keypad / RF Receiver Telemetry

Daikin Altherma Diagnostic Profile (24 Codes)

DIY Safe (External): 0 (0%)Pro Only: 24
Auto-Recovering: 11 (46%)Latched: 13
Severity Distribution
● Crit 17● Warn/Med 7
OEM Manual Coverage: 100%OEM Portal ↗
Showing 24 / 24
Fault A1
Pro OnlyCritical

Daikin Altherma Fault A1: Indoor Unit PCB / EEPROM Failure

Indoor Hydrobox or indoor fan-coil control PCB failed internal EEPROM checksum verification or logic diagnostics.

Est. Cost: $280 - $650Fix Guide →
Fault A6
Pro OnlyCritical

Daikin Fault A6: Indoor Fan Motor Lock / Blower Overload

Indoor blower fan motor locked or failed RPM feedback diagnostics, halting airflow and heating/cooling output.

Est. Cost: $190 - $480Fix Guide →
Fault C4
Pro OnlyWarning

Daikin Altherma Fault C4: Heat Exchanger Thermistor Abnormality

Indoor plate/evaporator heat exchanger thermistor (`R2T`) reported out-of-range open or shorted resistance.

Est. Cost: $140 - $290Fix Guide →
Fault C9
Pro OnlyWarning

Daikin Fault C9: Suction / Return Air Thermistor Failure

Indoor return/suction air thermistor (`R1T`) drifted outside valid resistance range, disabling temperature control.

Est. Cost: $120 - $260Fix Guide →
Fault E1
Pro OnlyCritical

Daikin Altherma Fault E1: Outdoor Unit PCB Defect / EEPROM Error

Outdoor inverter control PCB failed EEPROM checksum or internal microprocessor health diagnostics.

Est. Cost: $340 - $890Fix Guide →
Fault E3
Pro OnlyCritical

Daikin Altherma Fault E3: High Pressure Switch Actuated (HPS Trip)

Refrigerant discharge pressure exceeded critical safety cut-off threshold, opening high-pressure protection.

Est. Cost: $160 - $440Fix Guide →
Fault E4
Pro OnlyCritical

Daikin Altherma Fault E4: Low Pressure Protection Actuated

Suction refrigerant pressure dropped below protective threshold due to low refrigerant charge, frozen outdoor coil, or blocked EEV.

Est. Cost: $180 - $520Fix Guide →
Fault E7
Pro OnlyCritical

Daikin Altherma Fault E7: Outdoor Fan Motor Lock / Failure

Outdoor unit brushless DC condenser fan locked mechanically or tripped overcurrent sensing.

Est. Cost: $220 - $590Fix Guide →
Fault H9
Pro OnlyWarning

Daikin Altherma Fault H9: Outdoor Ambient Air Thermistor Fault

Outdoor ambient air NTC thermistor (`R1T`) mounted behind rear condenser fins failed out of valid ohmic range.

Est. Cost: $120 - $270Fix Guide →
Fault J3
Pro OnlyCritical

Daikin Altherma Fault J3: Discharge Pipe Thermistor Abnormality

Outdoor compressor discharge pipe thermistor failed high-temperature insulation or continuity checks.

Est. Cost: $160 - $340Fix Guide →
Fault J6
Pro OnlyWarning

Daikin Altherma Fault J6: Outdoor Heat Exchanger Coil Sensor Fault

Outdoor condenser/evaporator coil thermistor (`R4T`) failed out of ohmic limits, disrupting winter defrost sensing.

Est. Cost: $140 - $300Fix Guide →
Fault L4
Pro OnlyCritical

Daikin Altherma Fault L4: Inverter Heatsink Overheating (`>93°C`)

Outdoor inverter power-module aluminum heatsink overheated past safe ceiling, shutting down compressor output.

Est. Cost: $140 - $420Fix Guide →
Fault L5
Pro OnlyCritical

Daikin Altherma Fault L5: Instantaneous Compressor Overcurrent

Outdoor inverter IPM bridge sensed severe compressor output overcurrent, halting drive immediately.

Est. Cost: $320 - $1,450Fix Guide →
Fault P4
Pro OnlyCritical

Daikin Altherma Fault P4: Inverter Radiator Fin Thermistor Fault

Outdoor inverter heatsink temperature sensor failed electrical continuity/range diagnostics on control board.

Est. Cost: $240 - $680Fix Guide →
Fault U0
Pro OnlyCritical

Daikin Altherma Fault U0: Insufficient Refrigerant / Gas Shortage

Thermodynamic temperature and pressure spreads detected insufficient R32/R410A refrigerant charge.

Est. Cost: $280 - $750Fix Guide →
Fault U2
Pro OnlyCritical

Daikin Altherma Fault U2: Power Supply / DC Bus Voltage Fault

Abnormal AC supply voltage, phase imbalance, or failed internal high-voltage DC link capacitor charge detected.

Est. Cost: $140 - $690Fix Guide →
Fault U4
Pro OnlyCritical

Daikin Altherma Fault U4: Indoor-to-Outdoor Comms Fault

Indoor Hydrobox controller failed to receive communication replies from the outdoor condensing unit.

Est. Cost: $120 - $650Fix Guide →
Fault U5
Pro OnlyWarning

Daikin Altherma Fault U5: User Controller Transmission Fault

Broken serial communication or address conflict between indoor unit main PCB and wired remote wall thermostat.

Est. Cost: $110 - $280Fix Guide →
Fault UA
Pro OnlyCritical

Daikin Altherma Fault UA: Indoor/Outdoor Combination Mismatch

Indoor and outdoor unit series, capacity ratings, or spare PCB jumper configurations are mismatched.

Est. Cost: $140 - $420Fix Guide →
Fault 7H
Pro OnlyCritical

Daikin Altherma Fault 7H: Water Flow Problem / Blocked Circulation

Insufficient heating water circulation flow measured through Hydrobox plate heat exchanger, halting heating.

Est. Cost: $110 - $340Fix Guide →
Fault 8H
Pro OnlyCritical

Daikin Altherma Fault 8H: High Outlet Water Temp / Heater Cutout

Hydrobox outlet water overheated beyond safe thermal limits or tripped electric backup heater thermal safety switch.

Est. Cost: $120 - $380Fix Guide →
Fault 80
Pro OnlyWarning

Daikin Altherma Fault 80: Entering Water Thermistor (`R4T/R2T`) Fault

Hydrobox Entering (Return) Water NTC thermistor reported invalid open or shorted resistance telemetry.

Est. Cost: $140 - $290Fix Guide →
Fault 81
Pro OnlyWarning

Daikin Altherma Fault 81: Leaving Water Thermistor (`R1T/Outlet`) Fault

Hydrobox Leaving (Flow) Water NTC thermistor reported out-of-range open or shorted resistance telemetry.

Est. Cost: $140 - $290Fix Guide →
Fault 89
Pro OnlyCritical

Daikin Altherma Fault 89: Plate Heat Exchanger Freeze Protection

Indoor brazed-plate heat exchanger temperature dropped toward freezing point, halting system to prevent plate rupture.

Est. Cost: $160 - $520Fix Guide →