Daikin Altherma Error Codes & Fix Guides
Europe's leading domestic heating and heat pump systems. Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Daikin Altherma Hardware Signal Topology
Daikin Altherma Diagnostic Profile (24 Codes)
Daikin Altherma Fault A1: Indoor Unit PCB / EEPROM Failure
Indoor Hydrobox or indoor fan-coil control PCB failed internal EEPROM checksum verification or logic diagnostics.
Daikin Fault A6: Indoor Fan Motor Lock / Blower Overload
Indoor blower fan motor locked or failed RPM feedback diagnostics, halting airflow and heating/cooling output.
Daikin Altherma Fault C4: Heat Exchanger Thermistor Abnormality
Indoor plate/evaporator heat exchanger thermistor (`R2T`) reported out-of-range open or shorted resistance.
Daikin Fault C9: Suction / Return Air Thermistor Failure
Indoor return/suction air thermistor (`R1T`) drifted outside valid resistance range, disabling temperature control.
Daikin Altherma Fault E1: Outdoor Unit PCB Defect / EEPROM Error
Outdoor inverter control PCB failed EEPROM checksum or internal microprocessor health diagnostics.
Daikin Altherma Fault E3: High Pressure Switch Actuated (HPS Trip)
Refrigerant discharge pressure exceeded critical safety cut-off threshold, opening high-pressure protection.
Daikin Altherma Fault E4: Low Pressure Protection Actuated
Suction refrigerant pressure dropped below protective threshold due to low refrigerant charge, frozen outdoor coil, or blocked EEV.
Daikin Altherma Fault E7: Outdoor Fan Motor Lock / Failure
Outdoor unit brushless DC condenser fan locked mechanically or tripped overcurrent sensing.
Daikin Altherma Fault H9: Outdoor Ambient Air Thermistor Fault
Outdoor ambient air NTC thermistor (`R1T`) mounted behind rear condenser fins failed out of valid ohmic range.
Daikin Altherma Fault J3: Discharge Pipe Thermistor Abnormality
Outdoor compressor discharge pipe thermistor failed high-temperature insulation or continuity checks.
Daikin Altherma Fault J6: Outdoor Heat Exchanger Coil Sensor Fault
Outdoor condenser/evaporator coil thermistor (`R4T`) failed out of ohmic limits, disrupting winter defrost sensing.
Daikin Altherma Fault L4: Inverter Heatsink Overheating (`>93°C`)
Outdoor inverter power-module aluminum heatsink overheated past safe ceiling, shutting down compressor output.
Daikin Altherma Fault L5: Instantaneous Compressor Overcurrent
Outdoor inverter IPM bridge sensed severe compressor output overcurrent, halting drive immediately.
Daikin Altherma Fault P4: Inverter Radiator Fin Thermistor Fault
Outdoor inverter heatsink temperature sensor failed electrical continuity/range diagnostics on control board.
Daikin Altherma Fault U0: Insufficient Refrigerant / Gas Shortage
Thermodynamic temperature and pressure spreads detected insufficient R32/R410A refrigerant charge.
Daikin Altherma Fault U2: Power Supply / DC Bus Voltage Fault
Abnormal AC supply voltage, phase imbalance, or failed internal high-voltage DC link capacitor charge detected.
Daikin Altherma Fault U4: Indoor-to-Outdoor Comms Fault
Indoor Hydrobox controller failed to receive communication replies from the outdoor condensing unit.
Daikin Altherma Fault U5: User Controller Transmission Fault
Broken serial communication or address conflict between indoor unit main PCB and wired remote wall thermostat.
Daikin Altherma Fault UA: Indoor/Outdoor Combination Mismatch
Indoor and outdoor unit series, capacity ratings, or spare PCB jumper configurations are mismatched.
Daikin Altherma Fault 7H: Water Flow Problem / Blocked Circulation
Insufficient heating water circulation flow measured through Hydrobox plate heat exchanger, halting heating.
Daikin Altherma Fault 8H: High Outlet Water Temp / Heater Cutout
Hydrobox outlet water overheated beyond safe thermal limits or tripped electric backup heater thermal safety switch.
Daikin Altherma Fault 80: Entering Water Thermistor (`R4T/R2T`) Fault
Hydrobox Entering (Return) Water NTC thermistor reported invalid open or shorted resistance telemetry.
Daikin Altherma Fault 81: Leaving Water Thermistor (`R1T/Outlet`) Fault
Hydrobox Leaving (Flow) Water NTC thermistor reported out-of-range open or shorted resistance telemetry.
Daikin Altherma Fault 89: Plate Heat Exchanger Freeze Protection
Indoor brazed-plate heat exchanger temperature dropped toward freezing point, halting system to prevent plate rupture.