Error F13Low✓ DIY Safe (External)↻ Auto-Recovers When Cleared• Verified 2026-11-13

Deye Error F13: Working Mode / Grid Type Change Transition

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SUN-SG05LP1, SG01HP3 & String Series

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 USD
Warranty may cover parts
Diag / Fix Time
1 - 5 mins
Operating Mode & Parameter Sync

⚡ Quick Engineering Answer

Deye • Error F13

Deye Error F13 is NOT a broken hardware defect or grid failure—it means Working Mode Change, automatically triggered whenever someone modifies battery/No-Battery settings, Grid Mode, or Time-of-Use control profiles on the touchscreen or Solarman app. It usually clears by itself within 60 seconds; if stuck, cycle DC and AC breakers for 1 minute.

Recovery Behavior:Normal automatic transition code: self-clears within 30–60 seconds as inverter relays reboot into the newly saved battery or grid configuration.
SCHEMATIC // Deye Error F13 — Hybrid PV + Storage Inverter Architecture
PERIMETER: EXTERNAL CHECK
Deye Error F13: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter paused momentarily to re-initialize power relays after changing Battery, Grid Type, or Operating Mode settings.
Trigger Threshold
Parameter write to Battery Mode, Grid Type, Frequency, or Operating Mode registers
Recovery Window
Auto-clears in 30–60 seconds; manual 1-min DC/AC reset only if frozen past 3 mins
Subsystem Affected
Inverter Control Firmware & Configuration Memory
Warranty Outlook
Normal programmed behavior (0% fault)

How Deye Error F13 Triggers

Unlike true utility failures, Deye Error F13 (Working_Mode_Change) is an informational pause engineered into SUN hybrid and string firmware. Whenever critical system parameters change—such as toggling No Battery mode, switching between Lithium BMS and AGM voltage control, altering Grid Standard frequency (50Hz vs 60Hz), or pushing remote settings via Solarman—the microcontroller drops AC relays safely for a controlled reboot.

Wait 60 seconds before touching anything when F13 appears right after pressing OK in settings. If the inverter occasionally gets stuck displaying F13 continuously past 2 minutes (for instance, saving conflicting grid frequency settings mid-day), executing one full 60-second external DC and AC power-off cycle resets initialization cleanly.

🔀 Hardware & Series Differences

Deye Hybrid Inverters (SG04LP1 / LP3 / HP3)
Working Mode Changed — triggers automatically after toggling No Battery, Grid Mode, or Time-of-Use updates

Self-resolves in ~30–60 seconds while internal DC bus re-initializes.

Solarman / Deye Cloud Remote Config Updates
May pop up unexpectedly for 30 seconds when installer pushes remote grid code or work-mode commands

Wait 2 minutes before investigating—no user action required during remote parameter updates.

🔍 Observable Symptoms

  • •Touchscreen flashes F13 right after saving settings on the inverter or Solarman app.
  • •Relays click offline briefly for 30–60 seconds before resuming green Normal status.
  • •No visible electrical damage, heat, or breaker trips.
  • •Occasionally lingers if conflicting settings (e.g., wrong grid frequency) were saved repeatedly.

⚙️ Ranked Root Causes

Intentional touch-screen change to Battery Mode, No-Battery setting, or Grid StandardHigh

Firmware enforces safe offline transition whenever foundational operating parameters change.

Installer remote configuration change pushed over Solarman / Deye CloudMedium

Cloud parameter sync resets relays briefly while new export or charging curves take effect.

Hung firmware reboot transition during rapid repeated menu savesLow

Tapping Save twice quickly stalls relay re-closure until a 60-second power cycle clears state.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1DISCHARGE / WAIT
Wait 60 Seconds Without Touching Switches

Allow automatic relay reboot timer to finish re-synchronizing into Normal operation.

2CHECK / VERIFY
Confirm Saved Settings Match System Hardware

Check Battery Settings screen if you switched Lithium vs No-Battery right before F13.

3DISCHARGE / WAIT
Run 1-Minute External Power Cycle (Only If Frozen > 3 Mins)

Switch external PV DC OFF, battery OFF, and AC breaker OFF for 60 seconds, then restore power.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Wait 2 Minutes for Automatic Relay Reboot

Homeowner Safe

When Error F13 pops up on screen or Solarman logs, leave all breakers ON for 2 full minutes so the microcontroller finishes applying the configuration change.

✓ Expected ResultInverter clicks back to 'Normal' green status automatically with zero intervention.
→ If Fault PersistsVerify nobody pushed conflicting remote settings via Solarman/Deye Cloud simultaneously.
2

Perform Clean 60-Second External Power Reset If Hung

Homeowner Safe

If F13 stays latched beyond 3 minutes, switch external PV isolator OFF, battery breaker OFF, and AC breaker OFF for 60 seconds until screen blanks out, then switch Battery ON, AC ON, and PV ON.

✓ Expected ResultClears stuck state transition immediately upon fresh boot.
→ If Fault PersistsCheck Grid Mode and Battery Mode menus on touchscreen to verify sensible parameters are checked.
3

Verify Correct 'No Battery' vs Lithium Mode Checkbox

Homeowner Safe

Tap Settings > Battery Setting on the front display and ensure 'No Batt' is ONLY checked if no battery bank is installed, then wait 60 seconds after tapping OK.

✓ Expected ResultEliminates repeated mode conflict loops.
→ If Fault PersistsAsk your installer to verify latest HMI/MCU firmware compatibility.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F13? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Solarman / Deye Cloud App (Event Log Check)
  • ✓External DC / AC Disconnect Switches
  • ✓Front Touchscreen Settings Access

❓ Frequently Asked Questions

Is Deye Error F13 an AC grid voltage failure?

No. On official Deye inverter manuals, Error F13 strictly denotes 'Working Mode Change'—an expected temporary reboot notice whenever operating or battery configurations change.

Do I need an electrician if Error F13 flashes once in Solarman?

No! If it cleared within a minute and green Normal status returned, it simply indicates a setting save or cloud schedule change completed safely.

What if Error F13 won't go away after waiting 10 minutes?

Shut down external PV, battery, and AC breakers for 60 seconds until the screen shuts black, then turn them back on. If still frozen, verify 'No Battery' or grid-code settings weren't saved incorrectly.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).