Deye Error F35: No Utility Grid Detected (AC Loss / Outage)

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SG05LP1, SG01HP3 & SUN-G03 String Series

Owner Action
Safe External DIY
No panel opening needed
Auto-Recovery
Yes (Self-Clears)
Resumes after cause clears
Est. Repair Cost
$0 (Utility/Breaker) - $220 (Wire/Breaker Repair)
Warranty may cover parts
Diag / Fix Time
5 - 30 mins
AC Utility Grid Connection

⚡ Quick Engineering Answer

Deye • Error F35

Deye Error F35 means AC No Utility Fault (AC_NoUtility_Fault)—the inverter senses zero utility voltage on its Grid AC input terminals. Common causes are an active neighborhood power blackout, a tripped external solar AC isolator/breaker in your switchboard, or a blown utility fuse. Homeowners can safely check utility power and external AC breakers.

Recovery Behavior:Auto-clears immediately once external AC utility power returns past the inverter's 60-second reconnection timer.
SCHEMATIC // Deye Error F35 — Hybrid PV + Storage Inverter Architecture
PERIMETER: EXTERNAL CHECK
Deye Error F35: AC Protection Relays, Breaker & Grid System DiagramHV DCACCHASSIS SEALED (EXT OK)PV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
AC Protection Relays, Breaker & Grid
Signal / Power Path
Dual AC Isolation Relays -> Main Breaker -> Utility
Safety Access Line
External Switches, Air/Filter & App Only

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter sensed complete loss of external AC utility voltage on its Grid input terminals.
Trigger Threshold
Measured AC Grid terminal voltage < 30V–50V RMS (complete grid loss)
Recovery Window
Auto-synchronizes within 60–300 seconds once street power returns smoothly
Subsystem Affected
AC Grid Input Voltage Sense & Main Breaker
Warranty Outlook
External outage or tripped breaker (0% inverter defect unless AC relays/fuses failed)

How Deye Error F35 Triggers

During an electrical utility blackout—or anytime someone flips off the dedicated Solar AC breaker inside the main switchboard—a hybrid Deye inverter intentionally isolates its Grid port relays to protect utility line workers (anti-islanding) while switching backup loads seamlessly onto battery/PV power, logging Error F35 (AC_NoUtility).

On pure grid-tied string models without batteries, F35 shuts output down completely until street voltage stabilizes. Note that on three-phase units, losing just ONE utility phase fuse outside at the street pole causes F35 even when some lights elsewhere in the house still glow dimly!

🔀 Hardware & Series Differences

Deye Hybrid Units (SG04LP1 / LP3 — Backup Active)
Grid utility lost; Backup LOAD port remains powered seamlessly by PV & battery

Watch battery SoC% during prolonged blackouts and conserve heavy backup appliances.

Three-Phase Utility Feed / Grid String Units
Single street fuse blow on L1, L2, or L3 drops three-phase utility recognition into F35

Verify all three poles of the Solar AC isolator sit ON and utility power has all 3 phases.

🔍 Observable Symptoms

  • •LCD displays Error F35 while Grid voltage icon reads 0V on the home power-flow diagram.
  • •Backup LOAD lights keep running off battery (on hybrids) while non-backed-up main panel appliances shut dark.
  • •Triggered during neighborhood grid outages or storms.
  • •Persists when utility street power is working if the dedicated Solar AC breaker tripped OFF.

⚙️ Ranked Root Causes

Active neighborhood electrical utility blackout or planned maintenanceHigh

Zero AC voltage from street feeder forces anti-islanding disconnect and logs F35.

Tripped external Solar AC breaker or switched-off rotary AC isolatorHigh

Lightning transient or accidental switch bump opens AC grid circuit between meter and inverter.

Blown single utility street-pole fuse on three-phase supplyMedium

One dead phase drops three-phase grid detection even though other home rooms stay lit.

Loose AC Grid terminal screw or burnt grid surge protector fuseLow

High-resistance AC breaker lug burns open and drops grid sensing at the inverter.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Check Whether House Non-Backup Lights Work

Test a regular wall outlet NOT on solar backup to see if utility grid power is actually out.

2AC ISOLATE
Inspect Main Switchboard Solar AC Breaker

Ensure the labeled 'Solar / Inverter Main AC' circuit breaker sits fully ON (reset cleanly once if tripped).

3DISCHARGE / WAIT
Wait 3 Minutes for Re-Synchronization

Once AC utility supply stabilizes, F35 vanishes automatically after the grid countdown.

🛡️

Safe External Scope: Do Not Open Covers or Probe Terminals

All checks below remain strictly outside the sealed enclosure (display apps, breaker sequence, airflow/filter clearances, or external plugs). Never open housing screws or expose live wiring.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● ALL STEPS CONTAINED HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
○ NOT ACCESSED IN THIS GUIDE

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 3 Completed
1

Confirm Neighborhood Grid Power & External Switchboard Breakers

Homeowner Safe

Check whether regular household grid outlets (like an oven or non-backup lights) have electricity and check your main electrical distribution box for a tripped Solar Inverter AC breaker or RCD switch. Flip a tripped breaker ON once—if it immediately trips back OFF, stop and call an electrician.

✓ Expected ResultSwitching a nuisance-tripped solar breaker ON restores normal grid sync immediately.
→ If Fault PersistsCheck the external wall rotary AC isolator next to the inverter is clearly in the ON position.
2

Read Incoming AC Grid Voltage in LCD Home Flow Screen

Homeowner Safe

Tap the Grid tower icon on the front Deye touchscreen to view incoming L1/L2/L3 Grid voltage readings without opening any casing.

✓ Expected ResultConfirms whether ALL phases show 0V (full outage/breaker) vs strictly one dead phase (missing street fuse).
→ If Fault PersistsOn a single dead street phase, contact your electricity utility distributor for phase restoration.
3

Conserve Backup Battery During Extended Blackouts

Homeowner Safe

While grid stays down under F35, turn off high-drain non-essential appliances on backup circuits and inspect Battery SoC% inside Solarman so solar panels can keep recharging essentials through daylight.

✓ Expected ResultSustains smooth off-grid backup continuity until utility grid comes back online.
→ If Fault PersistsIf utility power works cleanly at the breaker yet the inverter still reads 0V Grid, schedule an electrician to test AC lug tightness.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F35? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

📋 Homeowner Preparation & Read-Only Access Needed

No electrical test instruments or aftermarket tools are required for these checks—have the following ready before starting:

  • ✓Deye Touchscreen Grid Voltage Flow Screen
  • ✓Main Distribution Switchboard Access
  • ✓Local Utility Outage Map

❓ Frequently Asked Questions

Does Deye Error F35 hurt my hybrid inverter?

Not at all! F35 is a harmless status indicator telling you utility grid power went missing (or the AC breaker switched off), while your hybrid safely supplies backup outlets from battery and solar.

Why does my inverter say F35 when half my house lights still turn on?

On homes with a three-phase connection, blowing a single street fuse leaves lights on two healthy phases working normally while the three-phase inverter detects one missing phase and safely disconnects!

If my Solar AC breaker keeps tripping off right after turning it back ON, what should I do?

Leave the breaker OFF immediately and call a qualified solar electrician—an instant trip means a dead short circuit in AC wiring or an internal inverter surge stage.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026

Reviewed and verified by the VoltFaults Engineering Standards Team. All diagnostic procedures, safety warnings, and component tests are cross-referenced directly with original manufacturer service documentation and international electrical safety codes (UL 1741, IEEE 1547 & IEC 62109).