Sungrow Error Codes & Fix Guides
World-leading manufacturer of high-efficiency utility, commercial, and residential hybrid solar inverters (SG and SH series). Select or filter any fault code below for trigger parameters, reset order, and step-by-step troubleshooting.
Sungrow Hardware Signal Topology
Sungrow Diagnostic Profile (16 Codes)
Sungrow Fault 003: Grid Transient Overvoltage Protection Trip
Instantaneous AC grid overvoltage exceeded Sungrow Stage I protection limits, forcing a protective grid relay disconnect until line voltage drops back within statutory range.
Sungrow Fault 008: AC Grid Over-Frequency Protection Trip
AC grid frequency exceeded the permissible upper safety limit, causing the Sungrow inverter to disconnect export power until grid frequency stabilizes.
Sungrow Fault 011: DC Current Injection High on AC Output
Excessive DC current component was detected on the inverter AC output lines, indicating asymmetric bridge switching, current-sensor drift, or internal IGBT stress.
Sungrow Fault 012: Excess Leakage Current (Residual Current Fault)
Differential current leakage to earth exceeded IEC 62109-2 safety thresholds, disconnecting the Sungrow inverter to prevent electric shock and rooftop fire hazards.
Sungrow Fault 014: 10-Minute Average Grid Overvoltage Trip
The rolling 10-minute average AC voltage at the Sungrow grid terminals exceeded regulatory limits, forcing a temporary grid export pause.
Sungrow Fault 015: High Grid Overvoltage (Stage II Trip)
Grid AC voltage breached the higher Stage II overvoltage protection ceiling, prompting immediate safety disconnection to protect connected appliances and power electronics.
Sungrow Fault 023: PV3 Input Overcurrent / PV Configuration Mode Fault
Abnormal DC input current on PV string channel 3 or an incompatible PV input configuration mode change forced a protective MPPT shutdown.
Sungrow Fault 024: PV4 Input Overcurrent / Neutral Point Voltage Deviation
Fault 024 flags abnormal current on PV string 4 or an internal neutral-point voltage asymmetry across the DC/AC power bridge.
Sungrow Fault 036: Radiator (Heatsink) Over-Temperature Protection
Excessive heat buildup on the inverter's rear cooling radiator triggered thermal derating or temporary shutdown until heatsink temperatures decline.
Sungrow Fault 037: Inverter Internal Over-Temperature Protection
Internal compartment temperature exceeded Sungrow hardware limits due to poor ambient ventilation, direct heat exposure, or blocked external air circulation.
Sungrow Fault 039: Low System Insulation Resistance (ISO Fault)
Pre-startup insulation testing measured DC PV-to-earth resistance below minimum IEC safety limits, locking out grid connection to prevent shock or arc fires.
Sungrow Fault 071: AC-Side Surge Protection Device (SPD) Alarm
The AC-side surge arrester (SPD) monitoring circuit detected a tripped, degraded, or disconnected varistor cartridge following a transient voltage spike.
Sungrow Fault 072: DC-Side Surge Protection Device (SPD) Alarm
The PV DC-side surge protection module tripped after absorbing a voltage surge, or internal DC bus voltage exceeded RMS hardware bounds.
Sungrow Fault 073: String DC Fuse Blown / Internal Bus Instantaneous Overvoltage
An internal string DC fuse ruptured due to string overcurrent/shorting, or internal DC bus voltage spiked past instantaneous protection limits.
Sungrow Fault 090: Parallel Synchronous Signal / Control Board Fault
Parallel inverter synchronization timing failed or an internal auxiliary control voltage rail dropped out of tolerance, halting operation.
Sungrow Fault 105: SPI Auto-Test / Grid Protection Self-Check Failure
The automated pre-connection grid protection relay and trip-time verification routine timed out or failed, blocking utility grid export.