Error F22High⚡ Pro Only (No Cover Open)■ Manual Action / Lockout• Verified 2026-11-13

Deye Error F22: Emergency Stop / Remote Shutdown (Hybrid)

Affected Models: Deye SUN-SG04LP1, SUN-SG04LP3, SG05LP1, SG01HP3 & SUN-G03 String Inverters

Owner Action
Pre-Check + Pro Call
Keep metal covers closed
Auto-Recovery
No (Latched Fault)
Requires reset or repair
Est. Repair Cost
$80 - $280 USD
Warranty may cover parts
Diag / Fix Time
15 - 60 mins
Emergency Stop & Rapid Shutdown

⚡ Quick Engineering Answer

Deye • Error F22

On Deye hybrid inverters (SG04LP1/LP3), Error F22 (Tz_EmergS_Fault) means an Emergency Stop, Rapid Shutdown (RSD) transmitter, or external remote shutdown contact is holding the inverter offline—it is NOT overheating (Igbt heat is F64). Note on three-phase SUN-G03 string units, F22 instead signals transient leakage or Phase Sequence error. Check external red E-Stop buttons safely first.

Recovery Behavior:Inverter holds shutdown until external Rapid Shutdown (RSD) button, BMS dry-contact interlock, or EMS remote-stop signal clears.
SCHEMATIC // Deye Error F22 — Hybrid PV + Storage Inverter Architecture
PERIMETER: SEALED ENCLOSURE
Deye Error F22: PV Array, AFCI & DC Boost Stage System DiagramHV DCACSEALED CHASSIS — PRO ONLYPV Strings & DCMC4 / AFCI / DC SPDDC Switch & FusesMPPT & CoolingBoost / HeatsinkFans & NTC ArrayPower Bridge & DSPIGBT / DC-Link CapsEEPROM / Dual-CPUAC Relays & GridL-N / Freq PLL / SPDIsolator & BreakerPE Earth & RisoRCMU / GFCI / GFDIInsulation ResistanceBattery & BMS LinkDC Fuse / BMS CANLV/HV Bus CutoffComms & CT MeterRS485 / Wi-Fi / USBFirmware & ProfileActive Fault ZoneSafety BoundaryFAULT TARGET HIGHLIGHTED
Highlighted Fault Node
PV Array, AFCI & DC Boost Stage
Signal / Power Path
Roof Strings / MC4 / Optimizers -> DC Isolator & MPPT
Safety Access Line
Sealed Chassis — RSD / Emergency Stop Terminal & Remote I/O

📊 Technical Specification & Trigger Matrix

Official Manual Definition
Inverter received an active Emergency Stop / Rapid Shutdown signal on hybrids, or phase/leakage alert on string units.
Trigger Threshold
External RSD/Emergency Stop dry contact asserted or remote Modbus stop bit held active
Recovery Window
Clears once external button releases or remote command clears; resets with power cycle
Subsystem Affected
RSD / Emergency Stop Terminal & Remote I/O
Warranty Outlook
External button bumped/tripped or installer RSD loop issue (rarely hardware)

How Deye Error F22 Triggers

Deye hybrid manuals designate Error F22 explicitly as Tz_EmergS_Fault (Emergency Stop / Remote Shutdown). Inside Deye's multi-function external communication/I-O terminal strip sits an Emergency Stop / Rapid Shutdown input loop alongside Dry Contact / Remote ON-OFF pins. When firefighters press an exterior rooftop RSD mushroom button, when a lithium battery rack smoke detector opens an interlock, or when an EMS/Smart Home relays a remote stop command, the inverter trips Error F22 immediately to kill hazardous AC and DC energy.

Watch out for model differences: on select three-phase string inverters (such as SUN-G03 models lacking hybrid RSD terminals), firmware maps F22 to Transient Leakage or Phase Sequence Fault. Always verify your unit series and check external red Rapid Shutdown / Emergency buttons before digging deeper.

🔀 Hardware & Series Differences

Deye Hybrid LV & HV (SG04LP1 / LP3 / HP3)
Tz_EmergS_Fault: Emergency Stop / Rapid Shutdown (RSD) / Remote OFF interlock open or asserted

Inspect exterior red RSD button (twisted/pulled out) and remote shutdown terminal wiring.

Deye 3-Phase Grid String (SUN-G03)
AC Phase Sequence Error or Transient Leakage fault on select string firmware

Verify L1/L2/L3 clockwise rotation if newly installed string unit reports F22.

🔍 Observable Symptoms

  • •Touchscreen displays Error F22 cleanly with zero thermal fan noise or scorched parts.
  • •Unit stays completely idle with 0W solar export and disabled backup loads.
  • •Red outdoor Rapid Shutdown mushroom button found pushed inward.
  • •Triggers spontaneously if homeowner accidentally tapped Remote Shutdown inside an app/EMS.

⚙️ Ranked Root Causes

Exterior Rapid Shutdown (RSD) / red Emergency Stop button pressed accidentallyHigh

Kids, yard equipment, or wall knocks depress latched outdoor E-stop switches requiring twist-to-release.

Loose wire or missing jumper inside Deye external Remote Shutdown / RSD blockHigh

Vibration opens normally-closed safety dry contacts or unplugs 24V RSD transmitter feed.

EMS / Solarman / Home Assistant Modbus writing Remote Off stateMedium

Automated demand-response scripts or wrong inverter setting checks trigger remote stop.

Three-phase L1/L2/L3 rotation swapped (SUN-G03 string units only)Low

Incorrect grid phase order on legacy G03 grid-tie firmware surfaces under F22.

🔄 Safe Shutdown & Reset Sequence Flow

Follow strict step order left-to-right
1CHECK / VERIFY
Inspect Wall Rapid Shutdown / Red Emergency Stop Switch

Check if a red push-button outside near your electricity meter was pressed in; twist clockwise to pop back out.

2CHECK / VERIFY
Check Solarman / Remote EMS App Status

Verify no automated demand-response app or remote installer disabled inverter output.

3CHECK / VERIFY
Cycle PV -> Battery -> AC Breakers (60 Seconds)

After popping out an RSD switch, run a clean external power cycle if F22 stays displayed.

⚠️

High-Voltage / Refrigerant Safety Boundary: Pro Service Split

Steps tagged "Homeowner Safe" below are strictly external read-only or external breaker inspections. Steps tagged "Licensed Technician" involve energized DC/AC bus voltages, isolation testing, or sealed refrigerant circuits—never attempt those steps without certification.

External Safe Zone
Display/App • AC/DC Switches • Airflow
● HOMEOWNER PRE-CHECKS STOP HERE
ENCLOSURE BARRIER
400–1000V DC Bus
✕ DO NOT OPEN COVERS
Internal Chassis (Pro)
Bus Capacitors • IGBT • Relays • Riso
⚡ LICENSED DISPATCH REQUIRED

🔧 Interactive Step-by-Step Diagnostic Checklist

Progress: 0 / 4 Completed
1

Check Exterior Rapid Shutdown / Emergency Stop Mushroom Button

Homeowner Safe

Walk outdoors beside your utility meter or inverter wall and inspect any red 'PV Rapid Shutdown' or 'Emergency Stop' push-button—if depressed, twist gently following its arrows so the red cap springs outward.

✓ Expected ResultReleasing a pressed outdoor emergency button clears the hardware lockout immediately.
→ If Fault PersistsPerform one 60-second external breaker cycle after unlatching the switch.
2

Check Solarman / BMS App & Remote ON-OFF Menus

Homeowner Safe

Verify in Deye Cloud/Solarman or smart-home automations (Home Assistant, Solar Assistant) that no 'Power Off' or remote shutdown command was sent inadvertently.

✓ Expected ResultRestoring normal enabled state removes remote F22 lockdown.
→ If Fault PersistsIf no button is pushed and no EMS disabled it, an installer must check internal I/O dry-contact terminals.
3

Inspect RSD Transmitter, Remote I/O Pins & LCD Pinout Bridge

Licensed Technician

Isolate unit safety power, open lower wiring compartment, check 24V RSD transmitter supply/fuses and pin seating on Emergency Stop / BMS interlock dry contacts; test continuity across E-stop switch.

✓ Expected ResultLocates broken exterior E-stop wire or blown 24V RSD power module cleanly.
→ If Fault PersistsOn SUN-G03 three-phase string models, verify L1-L2-L3 phase rotation order with phase rotation meter.
4

Verify Advanced Function Enable Bits & Firmware

Licensed Technician

Check Deye touchscreen Advanced Settings for inadvertent 'Remote Lock / External Stop' toggles; clear locked status bit and test full startup.

✓ Expected ResultSystem exits Error F22 and enters clean grid/solar synchronization.
→ If Fault PersistsUpdate HMI/MCU firmware or service faulty I/O optocoupler board.

📋 Ready-to-Send Technician Fault Brief

Completed safe checks without clearing Error F22? Copy this structured engineering summary for your installer or OEM RMA ticket.

Request Certified Tech Dispatch ↓

🧰 Field Reference: What Your Technician Will Inspect

For homeowner safety, DIY replacement tools are disabled on this fault code. Your certified electrician or technician should bring:

  • •Digital Multimeter (Continuity & 24V DC)
  • •Phase Rotation Meter (For SUN-G03 3-Phase String)
  • •External RSD Wiring Diagram
⚠️
High Hazard AlertLicensed Electrician Required

Don't Risk High-Voltage Shock with Deye Error F22

This fault involves internal bridge or DC intermediate capacitor stages. Under NEC & UL guidelines, probing energized solar conductors can cause lethal arc flash. Get competitive quotes from licensed solar electricians in your postal area:

✓ No obligation quotes✓ Pre-screened NABCEP certified contractors✓ 100% Free dispatch

❓ Frequently Asked Questions

Does Deye Error F22 mean my inverter is overheating?

No! Overheating / IGBT Heat Sink temperature is Fault F64 on Deye hybrids. Error F22 strictly means Emergency Stop / Rapid Shutdown (Tz_EmergS_Fault) on Deye hybrid models.

Can kids bumping an outdoor Rapid Shutdown switch cause Error F22?

Yes—this is one of the single fastest real-world causes. Outdoor emergency mushroom buttons latch down with one light bump and require twisting the red head clockwise to release.

Why does my SUN-G03 string manual list F22 differently?

Deye's older grid-only three-phase string series maps F22 to Transient Leakage or Phase Sequence rotation rather than Hybrid Emergency Stop loops—always verify by unit model.

Related Deye Fault Codes

VF
VoltFaults Engineering Review Board✓ Verified Technical Standards• Updated November 2026